Mitsubishi Electric JT-SB116JH-G-NA Handbook page 23

Hide thumbs Also See for JT-SB116JH-G-NA:
Table of Contents

Advertisement

(10) Blower (assembly)
1 Remove the blower cover. → See (9) 1 to 6.
Precaution
• Since the blower (assembly) may drop off the blower case, remove
the lead wires first, and then slowly remove the blower cover.
Assembly precautions
• When replacing the blower (assembly), attach the included fixing
piece to the position, indicated by , with a screw (one PTT screw
4×16).
• Set the blower (assembly) as the lead wire outlet comes to the
position indicated by .
• The part of the lead wires covered by the white cord tube must
pass through the cord bush. (Indicated by )
2 Remove the blower (assembly).
Assembly precaution
Run each lead wire through the hole of the cord bush.
(Indicated by )
(11) Switch
1 Disconnect the switch lead wires (black) from the control circuit board
(JT-30M4/JT-30M4A). → See (3) 1 to 4.
2 Remove the TB fix plate. → See (7) 2 to 3.
3 Push out the switch in the direction of the arrow, and remove it.
─ 23 ─
Set the blower horizontally.
Blower (assembly)
Switch lead wires (black)
Switch