Connecting To Els Vision - Electrolux DC6-8HP m Installation Manual

Drying cabinet
Table of Contents

Advertisement

30

7.2 Connecting to ELS Vision

Connect the network cables GND, RX, TX, 24V to the terminal block. Connect the neutral position switch to terminal
block positions 1 and 2.
Activate the connection to ELS Vision as follows:
• Activate the programming mode: Press STOP + SUN + BUTTERFLY. Press the Stop button first and then the pro-
gram selection buttons simultaneously. The display lights up and shows "ACCESS 1000". To be able to move on,
code 9191 must replace the code 1000.
• After the above, you will be at the first digit "1" in ACCESS 1000. Step to the digit "9" using the program selection
buttons SUN (up) or BUTTERFLY (down). Then move to the next digit, in this case "0", using the STOP button. In-
crease this to "1" using the SUN button and then continue until "9191" is shown. Once you have set the last digit,
press the STOP button and access programming mode.
• The first parameter and the factory-set value are then shown in the display. The row with the parameter flashes.
• Step forward or back with the SUN (increase) or BUTTERFLY (decrease) button to Parameter 117 is shown. Press
STOP to confirm.
• Select the baud rate that matches the setting in ELS Vision:
– 0: off, 1: 2400 bps, 2: 4800 bps, 3: 9600 bps. Use the Stop button to exit the parameter.
• Press STOP to save.
• Then access parameter 118 and set network address 1–127. Use the Stop button to exit the parameter.
• Press STOP to save.
• To exit programming mode, press STOP + BUTTERFLY (STOP button first).
1
Stop button
2
Sun button
Extra drying
3
Butterfly button
Normal drying
Installation manual
1
2
3
fig.W01529
fig.W01296