1
Connect the wire.
For the connection details, refer to the
installation manual for the indoor unit.
Attach the connecter directly to the
printed circuit board (PCB).
NOTE: Options connecting to CN65 can-
not be used at the same time.
2
Install the WLAN adapter.
Install the WLAN adapter in the direction as shown in the
figure.
If the WLAN adapter is installed in the wrong direction,
water may get into the adapter through the wire, causing
failure.
GOOD
Do not lay the WLAN adapter cable on the floor. You may trip on the cables.
GOOD
3
Connect the indoor unit to the power supply.
Wait until the LED 1 stops the blinking (LED1: on, LED 2: on).
It takes about 10 seconds.
4
Connect the WLAN adapter and the access point.
Refer to the operation manual of
Reverse direction
PROHIBITED
AIRSTAGE Mobile
WLAN adapter cable
with connector
PROHIBITED
On the floor
for details.
Indoor unit
PCB
CN65
Self-tapping
screws
(accessory)
On a curved surface
En-17