5. Safety parameters of FR-D700-SC

FR-D700-SC safety related I/O status obeys the following truth table.
Table.6 Safety parameters of FR-D700-SC
Parameter
PFD
AVG
PFH
D
PL
MTTF
D
DC
AVG
8
Value
-4
2.06x10
-9
2.35x10
d
725 years
60%