Mitsubishi Electric 800-GF Manual page 91

Advertisement

3
Extended detection time of the output current and zero
current
The setting range of the Pr.151 Output current detection signal delay time and Pr.153 Zero current detection
time is extended.
Pr.
Name
151
Output current detection
M461
signal delay time
153
Zero current detection
M463
time
4
Selecting the command interface in the Network
operation mode (Pr.338, Pr.339)
• The proximity dog (X76) signal can be input via communication.
• The following table shows the command interface for the function in the Network operation mode, determined by
the parameter settings: an external terminal or a communication interface (RS-485 terminals or communication
option).
Pr.338 Communication operation command source
Pr.339 Communication speed command source
X76
Proximity dog
[Explanation of Terms in Table]
EXT: External terminal only
Combined: Either external terminal or communication interface
Initial
Setting range
value
0 s
0 to 300 s
0.5 s
0 to 300 s
0: NET
Combined
3
Description
Set the output current detection time. Enter the time from
when the output current reaches the set current or higher
to when the Output current detection (Y12) signal is output.
Set the time from when the output current drops to the
Pr.152 setting or lower to when the Zero current detection
(Y13) signal is output.
0: NET
1: EXT
2: EXT
1: EXT
0: NET
1: EXT
2: EXT
EXT
BCN-C22005-991