Kenwood CK 446 Instructions For Use Manual page 43

Dual fuel double oven cooker
Table of Contents

Advertisement

2 - Adjusting of the minimum
of the top burners
In the minimum position the flame must
have a length of about 4 mm and must
remain lit even with a quick turn from the
maximum position to that of minimum.
The flame adjustment is done in the fol-
lowing way:
– Turn on the burner
– Turn the tap to the MINIMUM position
– Take off the knob
– With a small flat screwdriver turn the
screw inside the tap rod to the correct
regulation (fig. 10.5).
Normally for LPG, tighten up the regula-
tion screw.
TABLE FOR THE CHOICE OF THE INJECTORS
BURNERS
Auxiliary (A)
Semi-rapid (SR)
Rapid (R)
Triple-ring (TR)
I
NCREASE OF AIR NECESSARY FOR GAS COMBUSTION
BURNERS
Auxiliary (A)
Semi-rapid (SR)
Rapid (R)
Triple-ring (TR)
Nominal
Reduced
Power
Power
[kW]
[kW]
1,00
0,30
1,75
0,45
3,00
0,75
3,50
1,50
LUBRICATION OF THE GAS TAPS
If a tap becomes stiff, do not force;
contact your local Service Agent.
IMPORTANT
All intervention regarding installation
maintenance and conversion of the
appliance must be fulfilled with origi-
nal factory parts.
The manufacturer declines any liabili-
ty resulting from the non-compliance
of this obligation.
G 30 - 28-30 mbar
G 31 - 37 mbar
By-pass
Ø injector
[1/100 mm]
[1/100 mm]
27
32
42
65
Air necessary for combustion [m
2,00
3,50
6,00
7,00
Cat:
G 20
20 mbar
By-pass
[1/100 mm]
50
65
85
95
3
(2 m
/h x kW)
3
/h]
Fig. 10.5
II
2H3+
Ø injector
[1/100 mm]
72 (X)
97 (Z)
115 (Y)
135 (T)
43