Linux - NEC N8103-121 User Manual

Raid battery backup unit
Table of Contents

Advertisement

57

2-2. Linux

1.
Enter the following command to check the property of RAID Controller.
# raidcmd property –tg=rc –c=C <ENTER>
"C" is the number of the RAID Controller. Following command is the example
when the number of RAID Controller is "1".
# raidcmd property –tg=rc –c=1 <ENTER>
2.
The property of the RAID Controller is displayed. If the battery status is displayed
"Normal", the battery is connected surely.
RAID Controller #1
ID
Vendor
Model
Firmware Version
Cache Size
Battery Status
Rebuild Priority
Consistency Check Priority
Patrol Read
Patrol Read Priority
Buzzer Setting
Indicates the status of the battery installed in the RAID Controller.
Three possible status are as follows:
Check
Normal: Indicates that the battery can be used normally.
Warning: Indicates that the battery cannot be used normally due to some reason.
Not Present: Indicates that no battery is installed in the RAID Controller.
: 0
: LSI Corporation
: MegaRAID SAS 8708EM2 (xxxMB)
: 1.xx.xx-xxxx
: xxxMB
: Normal
: Low
: Low
: Enable
: Low
: Disable