Masterdrives cbc - communication board can-bus (755 pages)
Summary of Contents for Siemens SITRANS SCM IQ
Page 1
Introduction Safety notes Installing/mounting SITRANS SCM IQ Connecting Digitalization SITRANS CC220 and SITRANS Commissioning MS200 Service and maintenance Compact Operating Instructions Technical specifications Product documentation and support 7MP2200-1CB05-2AA1 (SITRANS CC220) 7MP2200-2CB05-2AA1 (SITRANS CC220 - IOT2050) 7MP2210-2AB21-2AB1 (SITRANS MS200) 10/2023 - DRAFT...
Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Table of contents Introduction ............................7 Purpose of this documentation .................... 7 Document history ........................ 7 FW revision history....................... 7 Designated use ........................7 Checking the consignment....................8 EXAMPLE - Nameplate layout ....................8 Industrial use note ....................... 9 Security information ......................9 Transportation and storage ....................
Page 4
Table of contents 3.1.4.2 Horizontal wall mounting....................30 3.1.5 Replacing the backup battery ..................... 31 3.1.6 Installing the top housing ....................34 Installation instructions SITRANS MS200 ................35 3.2.1 Basic safety notes SITRANS MS200 ..................35 3.2.1.1 Installation location requirements ..................36 3.2.2 General description......................
Page 5
Table of contents Technical support....................... 68 Index ..............................69 SITRANS CC220 and SITRANS MS200 Compact Operating Instructions, 10/2023 - DRAFT, A5E...-AA...
Page 6
Table of contents SITRANS CC220 and SITRANS MS200 Compact Operating Instructions, 10/2023 - DRAFT, A5E...-AA...
Introduction Purpose of this documentation These instructions are a brief summary of important features, functions and safety information, and contain all information required for safe use of the device. Read the instructions carefully prior to installation and commissioning. In order to use the device correctly, first review its principle of operation.
Introduction 1.6 EXAMPLE - Nameplate layout Checking the consignment 1. Check the packaging and the delivered items for visible damages. 2. Report any claims for damages immediately to the shipping company. 3. Retain damaged parts for clarification. 4. Check the scope of delivery by comparing your order to the shipping documents for correctness and completeness.
In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks.
Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure...
Page 11
Introduction 1.10 Notes on warranty The content reflects the technical status at the time of publishing. Siemens reserves the right to make technical changes in the course of further development. SITRANS CC220 and SITRANS MS200 Compact Operating Instructions, 10/2023 - DRAFT, A5E...-AA...
Page 12
Introduction 1.10 Notes on warranty SITRANS CC220 and SITRANS MS200 Compact Operating Instructions, 10/2023 - DRAFT, A5E...-AA...
Safety notes Preconditions for use This device left the factory in good working condition. In order to maintain this status and to ensure safe operation of the device, observe these instructions and all the specifications relevant to safety. Observe the information and symbols on the device. Do not remove any information or symbols from the device.
United Kingdom. The applicable regulations can be found in the UKCA declaration of conformity of the specific device. See also Certificates (http://www.siemens.com/processinstrumentation/certificates) SITRANS CC220 and SITRANS MS200 Compact Operating Instructions, 10/2023 - DRAFT, A5E...-AA...
Note Operation under special ambient conditions We highly recommend that you contact your Siemens representative or our application department before you operate the device under special ambient conditions as can be encountered in nuclear power plants or when the device is used for research and development purposes.
Page 16
Safety notes 2.3 Requirements according to 15.19. (FCC) / RSS-GEN L'exploitation est autorisée aux deux conditions suivantes: 1. l'appareil ne doit pas produire de brouillage, et 2. l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. NOTICE: Changes or modifications made to this equipment not expressly approved by (manufacturer name) may void the FCC authorization to operate this equipment.
Safety notes 2.4 Use in hazardous areas Use in hazardous areas Qualified personnel for hazardous area applications Persons who install, connect, commission, operate, and service the device in a hazardous area must have the following specific qualifications: • They are authorized, trained or instructed in operating and maintaining devices and systems according to the safety regulations for electrical circuits, high pressures, aggressive, and hazardous media.
Safety notes 2.5 Basic safety notes SITRANS CC220 Basic safety notes SITRANS CC220 2.5.1 Basic safety notes Battery and rechargeable battery WARNING Risk of explosion and release of harmful substances Improper handling of lithium batteries can result in an explosion of the batteries. Explosion of the batteries and the released pollutants can cause severe physical injury.
2.5.2 Data protection Siemens observes the data protection guidelines, especially the requirements regarding data minimization (privacy by design). This means the following for this product: The product does not process / save any personal information, but only technical functional data (e.g. time stamps).
• The device can be identified by collecting MAC/UID information from the system. • Note that the debug interface X14 on the motherboard is used for development purposes. • The micro USB port is only allowed to be used by Siemens personal. Basic safety notes SITRANS MS200 2.6.1...
Battery pack specification NOTICE Unsuitable battery pack SITRANS MS200 is delivered with an LTC (Lithium Thionyl Chloride) battery pack offered by Siemens. • Use SITRANS MS200 with the delivered battery pack only. See also Ordering of spare parts (Page 58) SITRANS CC220 and SITRANS MS200...
• Observe the relevant DIN/VDE requirements or the applicable country-specific regulations. • Install the bluetooth antenna outside the cabinet. • To install the mounting clamps and brackets, Siemens recommends you use 0.6 Nm tightening torque. Before mounting the device You have all needed anchors and screws available.
Page 24
Installing/mounting 3.1 Installation instructions SITRANS CC220 4. Mount the bluetooth antenna extension. See technical details of the bluetooth antenna extension in chapter Technical specifications SITRANS CC220 (Page 63). 5. Bring the bluetooth antenna in a vertical position. Mounting example in a cabinet See technical details of the bluetooth antenna extension in chapter Technical specifications SITRANS CC220 (Page 63).
Installing/mounting 3.1 Installation instructions SITRANS CC220 3.1.2 Mounting positions and mounting types The device can be mounted horizontally or vertically on a DIN rail or to a wall. Vertical mounting position, recommended Horizontal mounting position Consider the permitted temperature range for operation that depends on the mounting position in accordance with the Technical specifications SITRANS CC220 (Page 63) chapter.
Installing/mounting 3.1 Installation instructions SITRANS CC220 3.1.3 Mounting on DIN rails 3.1.3.1 Secure the mounting clips Requirement • The DIN rail is installed at the installation site (35 mm standard profile). • Mounting bracket and mounting clamps • Two screws • T8 screwdriver SITRANS CC220 and SITRANS MS200 Compact Operating Instructions, 10/2023 - DRAFT, A5E...-AA...
Page 27
Installing/mounting 3.1 Installation instructions SITRANS CC220 Secure the mounting clips for vertical mounting 1. Lay the rail clamp on the rear of the device. 2. Fasten the rail clamp with the supplied screws. Secure the mounting clips for horizontal mounting 1. Lay the rail clamp on the rear of the device.
Installing/mounting 3.1 Installation instructions SITRANS CC220 3.1.3.2 Mounting on DIN rails Mounting 1. Place the device and rail clamp on the upper edge of the standard profile rail at the position shown and push the device down. 2. Swing the rail clamp of the device from below through the standard profile rail. 3.
Installing/mounting 3.1 Installation instructions SITRANS CC220 3.1.4 Wall mounting 3.1.4.1 Vertical wall mounting Note The device must be installed on the plate of an enclosure. Requirement • 2 mounting brackets • 2 screws • T8 screwdriver Procedure for mounting 1. Lay the mounting brackets on the rear of the device. 2.
Installing/mounting 3.1 Installation instructions SITRANS CC220 3.1.5 Replacing the backup battery Prior to replacement WARNING Risk of explosion and release of harmful substances Improper handling of lithium batteries can result in an explosion of the batteries. Explosion of the batteries and the released pollutants can cause severe physical injury. Worn batteries jeopardize the function of the device.
Page 32
Installing/mounting 3.1 Installation instructions SITRANS CC220 Procedure Remove the power plug and marked screws. Loosen the top housing. Care‐ fully press with the blade of a flat-blade screwdriver in the marked recesses and carefully pull on the appropriate place on the top housing of the en‐ closure.
Page 33
Installing/mounting 3.1 Installation instructions SITRANS CC220 Pull the plug of the battery ca‐ ble from the motherboard. Remove the battery. Paste the double side tap on the battery and then paste it on the display port socket. Plug in the battery cable on the motherboard.
Installing/mounting 3.1 Installation instructions SITRANS CC220 3.1.6 Installing the top housing Installing the top housing 1. Align the bottom of the top housing to the heatsink edge. Make sure the marked hooks hooked the heatsink. Carefully insert the COM interface into the top housing. 2.
Note Material compatibility Siemens can provide you with support concerning selection of parts wetted by process media. However, you are responsible for the selection of parts. Siemens accepts no liability for faults or failures resulting from incompatible materials. CAUTION Hot surfaces resulting from hot process media Risk of burns resulting from surface temperatures above 65 °C (149 °F).
Installing/mounting 3.2 Installation instructions SITRANS MS200 3.2.1.1 Installation location requirements NOTICE Aggressive atmospheres Damage to device through penetration of aggressive vapors. • Ensure that the device is suitable for the application. NOTICE Direct sunlight Damage to device. The device can overheat or materials become brittle due to UV exposure. •...
Note Mount SITRANS MS200 so that the lid can be easily removed in the mounted state for a later battery pack replacement (Page 52). For more information, watch this video: SITRANS SCM IQ: How to mount the Multisensor (https://www.youtube.com/watch?v=kHCWsAgltqE) Note Influences on data transmission The positioning of the sensors and the gateway as well as the environmental conditions influence the data transmission between SITRANS MS200 and SITRANS CC220.
Installing/mounting 3.3 Disassembly SITRANS MS200 3.2.4 Installing SITRANS MS200 on a gear Mount SITRANS MS200 directly on the gear. The most suitable place is at the middle of the gear in the horizontal position. NOTICE Maximum specified ambient temperature The maximum specified ambient temperature must not be exceeded by the gear. See Technical specifications SITRANS MS200 (Page 65).
Connecting Basic safety notes WARNING Risk of lightning strikes A lightning flash may enter the mains cables and data transmission cables and jump to a person. Death, serious injury and burns can be caused by lightning. Take the following precautions: •...
Connecting 4.2 Connecting SITRANS CC220 NOTICE Condensation in the device Damage to device through formation of condensation if the temperature difference between transportation or storage and the mounting location exceeds 20 °C (36 °F). • Before taking the device into operation, let the device adapt for several hours in the new environment.
Page 41
Connecting 4.2 Connecting SITRANS CC220 WARNING Electric shock and risk of fire High voltage may be present in a defective device, which can cause fire or an electric shock if touched. This can result in death and serious injury. • Connect the device to the functional grounding before you put it into operation. •...
Connecting 4.2 Connecting SITRANS CC220 4.2.2 Connecting SITRANS CC220 Before connecting SITRANS CC220 • You have connected functional grounding (Page 40). • You are using the supplied terminal. • A two-core cable meet the following requirements: – a copper (Cu) cable with cross-section of 0.75 to 2.5 mm –...
Commissioning Basic safety notes WARNING Commissioning and operation with pending error If an error message appears, correct operation in the process is no longer guaranteed. • Check the gravity of the error. • Correct the error. • If the error still exists: –...
Service and maintenance Basic safety notes Note The device is maintenance-free. 6.1.1 Maintenance The device is maintenance-free. However, a periodic inspection according to pertinent directives and regulations must be carried out. An inspection can include: • Ambient conditions • Seal integrity of the process connections, cable entries, and cover •...
WARNING Impermissible repair and maintenance of the device • Repair and maintenance must be carried out by Siemens authorized personnel only. CAUTION Hazardous voltage at open device Risk of electric shock when the enclosure is opened or enclosure parts are removed.
Service and maintenance 6.2 Maintenance and repair work for SITRANS CC220 If you install or exchange system expansions and damage your device, the warranty becomes void. CAUTION Electrostatic sensitive devices (ESD) The device contains electronic components which are destroyed by electrostatic charges. This can result in malfunctions and damage to the machine or plant.
7. If no LED is blinking anymore, remove the USB stick from SITRANS CC220. 8. Send the log files to the Technical support (Page 68). 9. Before you establish a connection of SITRANS CC220 to SITRANS SCM IQ again (Onboarding), remove the "ConBox_Commands.json" file from the USB stick.
Page 49
Service and maintenance 6.2 Maintenance and repair work for SITRANS CC220 NOTICE Disposal of batteries and rechargeable batteries Batteries and rechargeable batteries do not belong in domestic garbage. The user is legally obliged to return used batteries and rechargeable batteries. Used batteries and rechargeable batteries pollute the environment as special waste. You as a user are liable to prosecution if you do not properly dispose of batteries and rechargeable batteries.
Service and maintenance 6.3 Maintenance and repair work for SITRANS MS200 4. Connect new SITRANS CC220. 5. Reconnect old SITRANS MS200 with SITRANS SCM IQ to the same MindSphere asset. 6. Reset SITRANS MS200. AUTOHOTSPOT 6.2.5 Updating firmware of SITRANS CC220 Introduction If a firmware update is required, you receive a notification in SITRANS SCM IQ.
Service and maintenance 6.3 Maintenance and repair work for SITRANS MS200 NOTICE Penetration of moisture into the device Damage to device. • Make sure when carrying out cleaning and maintenance work that no moisture penetrates the inside of the device. 6.3.2 Replacing SITRANS MS200 battery pack WARNING Corrosive substances...
Page 53
Service and maintenance 6.3 Maintenance and repair work for SITRANS MS200 Procedure ② ① 1. Unscrew the sensor lid: Hold with an open-ended wrench at and turn the lid counterclockwise. ① 2. Lift up the lid CAUTION Electrostatic sensitive devices (ESD) The device contains electronic components which are destroyed by electrostatic charges.
Page 54
Service and maintenance 6.3 Maintenance and repair work for SITRANS MS200 ③ 3. Disconnect the battery connector ④ 4. Unwrap the wires ⑤ 5. Disengage the snaps SITRANS CC220 and SITRANS MS200 Compact Operating Instructions, 10/2023 - DRAFT, A5E...-AA...
Page 55
⑦ 7. Take off the battery holder cap 8. Lift and exchange the battery pack with a Siemens specified battery pack (see Ordering of spare parts (Page 58)). Ensure that the positive terminal of the battery pack points upwards. 9. Wrap the cable in its original position using the dedicated snaps of the battery holder.
Service and maintenance 6.3 Maintenance and repair work for SITRANS MS200 ⑦ 10.Put the battery holder cap back on. Ensure that the battery holder cap is correctly snapped ③ 11.Connect the battery connector ⇒ The LED placed on the PCBA lights up for one second. ①...
Page 57
1. Stop anomaly detection models of the respective SITRANS MS200. 2. Reposition SITRANS MS200. 3. Make sure SITRANS MS200 is powered up. 4. Change assignment to MindSphere asset of SITRANS MS200 in SITRANS SCM IQ by clicking on "Device configuration > > Configure sensor".
Service and maintenance 6.4 Ordering of spare parts 1. Stop anomaly detection models of the respective SITRANS MS200. 2. Change assignment to MindSphere asset of SITRANS MS200 in SITRANS SCM IQ by clicking on "Device configuration > > Configure sensor". 3. Delete machine learning models based on old data from asset (if existing) by clicking on "Sensor data modelling"...
5. Select a spare part and add it to your watch list. The watch list opens. 6. Click "Add to cart of Industry Mall". The Siemens Industry Mall opens and you can order your spare part. Cleaning Cleaning the enclosure •...
To return a product to Siemens, see Returns to Siemens (https:// support.industry.siemens.com/cs/ww/en/sc/3098). Contact your Siemens representative to clarify if a product is repairable, and how to return it. They can also help with quick repair processing, a repair cost estimate, or a repair report/ cause of failure report.
Page 61
Service and maintenance 6.7 Disposal Note Special disposal required The device includes components that require special disposal. • Dispose of the device properly and environmentally through a local waste disposal contractor. SITRANS CC220 and SITRANS MS200 Compact Operating Instructions, 10/2023 - DRAFT, A5E...-AA...
Page 62
Service and maintenance 6.7 Disposal SITRANS CC220 and SITRANS MS200 Compact Operating Instructions, 10/2023 - DRAFT, A5E...-AA...
Technical specifications Technical specifications SITRANS CC220 Basic specifications Distance between 2 SITRANS CC220 Minimum 30 cm Weight without mounting brackets 400 g Power supply DC 12 to 24 V Brief voltage interruption in accord‐ Up to 5 ms buffer time at 24 V DC and full load ance with Namur Max.
Page 64
Technical specifications 7.1 Technical specifications SITRANS CC220 Climatic ambient conditions Permitted mounting positions. See section "Mounting positions and mounting types (Page 25)“. Ambient temperature DIN rail-mount • Operation • Vertical: 0 ... 50 °C • Horizontal: 0 ... 40 °C Wall mounting • Vertical: 0 ... 45 °C •...
Technical specifications 7.2 Technical specifications SITRANS MS200 Wireless communication Bluetooth® (standard) Max. receive sensitivity -103 dBm (BLE LR-125k) Antenna rod antenna Distance to SI‐ up to 30 m TRANS MS200 Connected sensors up to 8 Data Transmission Cycle 1 per 100 seconds Certificates and appro‐ ...
Technical specifications 7.3 Certificates and approvals SITRANS MS200 Temperature measurement Accuracy ±4 °C Data format 16 bits Vibration measurement Vibration sensor 3-axis accelerometer Frequency range 13 ... 3 300 Hz Measurement range ±16 g Resolution 0.488 mg Repeatability ±10 mg Accuracy ±10% of measurement range Sampling rate 6 600 Hz Data format 16 bits...
– "Download as html5, only PC": Open or save the manual in the HTML5 view on your PC You can also find manuals with the Mobile app at Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/sc/2067). Download the app to your mobile device and scan the device QR code. Product documentation by serial number Using the PIA Life Cycle Portal, you can access the serial number-specific product information including technical specifications, spare parts, calibration data, or factory certificates.
Page 68
(http:// www.siemens.com/automation/csi/service). Service & support on the Internet In addition to our technical support, Siemens offers comprehensive online services at service & support (http://www.siemens.com/automation/serviceandsupport). Contact If you have further questions about the device, contact your local Siemens representative at Personal Contact (http://www.automation.siemens.com/partner).
Page 69
Index Article number Hazardous area on the nameplate, 8 Laws and directives, 13 Qualified personnel, 17 Hotline, (Refer to Support request) Backup battery Installing, 31, 49 Basic specifications, 63 Installation on a DIN rail, 25 Battery pack specification, 21 Installing Battery unit, 60 Backup battery, 31, 49 Installing SITRANS MS200, 36 on a gear, 38 on a pump or compressor, 37 on rotating or vibrating equipment, 38...
Page 70
Index Order code, 8 Wall mounting, 25, 29, 30 Ordering supplement, 8 Warning symbols, 13 Warranty, 10 Weight, 63 SITRANS MS200, 65 Power supply Connecting, 39 DC power supply, 64 SITRANS MS200, 65 Product name, 8 Qualified personnel, 17 Radiation, 18 High frequency radiation, 18 Repairs, 46 Replacing battery pack, 53 Return procedure, 60 Scope of delivery, 8 Service, 68 Service and support Internet, 68...