46/70
Servicing and repair
Bosch Rexroth AG, General Operating Instructions HYDROTRAC GFT 8000 series 40, RE 79022-01-B/04.2020

10.2 Inspection

Perform visual controls and inspections as specified in chapter
10.3 "Maintenance schedule planetary gearbox".

10.2.1 Visual inspections

Check for leakage in accordance with the intervals specified in the maintenance
schedule in chapter 10.3 "Maintenance schedule planetary gearbox". Signs of
leakage include more and more frequent moisture areas on the partition seams
or even oil drops.

10.2.2 Checking the oil level of the planetary gearbox via the cover side

Danger of burns!
The planetary gearbox heats up to a max. of 90 °C during operation in the oil
sump, so that you can burn yourself!
Allow the planetary gearbox to cool down to approx. 50 °C before touching.
To protect yourself from burns, wear appropriate protective clothing such as
heat-resistant safety gloves.
Always wear protective goggles.
Risk of injury!
Solid particles, such as metal particles or metal abrasion, which are in the
lubricating oil or on the screw plug can cause injury!
Wear appropriate protective clothing.
Risk of damaging the planetary gearbox!
If the oil level is too high or too low, damage or failure may result to the planetary
gearbox. If the oil level is too high, this may indicate that a foreign fluid, e.g.
pressure fluid or water, may have ingressed. If the oil level is too low, this may
indicate an oil leak!
Check for any leaks if the oil level is too low.
Determine the cause before refilling. Contact the Rexroth Service located in
your area, for the address refer to appendix A "Address directory" in the
material number-specific operating instructions.
CAUTION
NOTE