Cooking zone timer (1..99 min)
When the hob is switched on, an
independent timer can be programmed for
every cooking zone.
Select a cooking zone, then select the
temperature setting and finally activate the
timer setting button
programmed to switch off a cooking zone.
Around the timer four LEDs are arranged.
These indicate which cooking zone the
timer has been set for.
10 seconds after the last operation, the
timer display changes to the timer that will
run out next (in cases where a timer is set
for more than one cooking zone).
When the timer has run down, a signal
sounds and the timer display shows ´00`
and, the assigned cooking zone timer LED
blinks. The programmed cooking zone will
be switched off and the ´H` will be displayed
if the cooking zone is hot.
The sound signal and the blinking of the
timer LED will be stopped automatically
after 2 minutes and/or by operating any
button.
Buzzer
While the hob is in operation, the following
activities will be signalled by the buzzer:
• Normal button activation will be
accompanied with a short sound signal
• Continuous button operation over a
longer period of time (10 seconds)
will be accompanied with a longer,
intermittent sound signal.
Boost Function
To use this function, a cooking zone must
be selected,with the desired cooking level
set. Then press the P(Boost) button.
The Boost function can only be activated
if it is applicable with the cooking zone
selected If Boost Function is active a ´P` is
shown on the corresponding display.
Activating the booster can exceed the
maximum power, in which case the
integrated power management will be
activated.
The necessary power reduction is shown
by the corresponding cooking zone display
blinking. Blinking is active for 3 seconds
and allows further adaptations of the
settings before power reduction.
, the timer can be
EN - 17
Error Codes
If there is an error, an error code will be shown on the
heater displays.
E1
Cooling Fan is disabled. Call an authorised
E3
Supply voltage is other than the rated values.
Switch the hob off by pressing
"H" disappears for all zones, switch the hob
on by pressing
the same error is displayed again, call an
authorised service agent.
E4
Supply frequency is different from the rated
values. Switch the hob off by pressing
, wait until "H" disappears from all
zones, switch the hob on by pressing
and continue to use. If the same error is
displayed again, switch the plug for the
appliance off and on. Switch the hob on by
pressing
and continue to use. If the same
error is displayed again, call an authorised
E5
Internal temperature of the hob is too high,
switch the hob off by pressing
heaters cool down.
E6
Communication error between the touch
control and heater. Call an authorised service
E7
Coil temperature sensor is disabled. Call an
authorized service agent.
E8
Cooler temperature sensor is disabled. Call
an authorized service agent.
EA
Large Coil Saturation Error. Switch the hob
off by pressing on/off button, switch the hob
on by pressing on/off button and continue to
use. If the same error is displayed again, call
an authorised service agent.
EC
Supply Voltage Error.Switch the hob off by
pressing on/off button, switch the hob on by
pressing on/off button and continue to use.
If the same error is displayed again, call an
authorised service agent.
C1-C8
Mcroprocessor alert. Switch the hob off by
pressing on/off button, switch the hob on by
pressing on/off button and continue to use.
If the same error is displayed again, call an
authorised service agent.
service agent.
,wait until
and continue to use. If
service agent.
and let the
agent.