3.0
3.1
1. Connect the power cord to the Charger 144-CHR-LI and to an AC
outlet. The LED Lamp blinks in Red [STAND BY]
NOTE: The rated input voltage for this unit is 100V-240V. Use of
voltages over 260V will result in damage to the charger.
2. Insert the Battery firmly into the charger.
The LED Lamp lights in green [CHARGING].
NOTE: Do not short-circuit the Charger by placing foreign materials
in the contacts on Charger, as this will damage the Charger.
3. Charging takes approximately 25 minutes (80% capacity) and
45 minutes (100% capacity).
When charging is finished, the LED Lamp lights in orange
[COMPLETION].
NOTE: If the LED Lamp displays solid red [HIGH TEMPERATURE],
remove the Battery from the Charger and allow it to cool down
before trying to charge it again.
4. When the battery will no longer charge or hold a charge, the LED
Lamp blinks quickly in red [IMPOSSIBLE TO CHARGE].
5. When the charger is out of order, the LED Lamp does not light up
even if AC power is supplied.
NOTE: Do not power the Charger with a portable generator.
3.2
ATTACHING & DETACHING THE BATTERY PACK
1. To attach the Battery, slide it into the base of the Tool
until it stops and the Latches engage.
2. After inserting the Battery, check that it is securely in
place by pulling it gently without pressing the Latches.
3. To detach the Battery, pull out the Battery while pressing
the Latches.
Slide in

OPERATING INSTRUCTIONS

CHARGING THE BATTERY

Tool
Battery
Latches
(both sides)
Pull Out
LED Lamp
Power Cord
3.3

COMPRESSION CYCLES

This guide indicates the number of compression cycles that
the TBM62CR-LI can be expected to perform when the
battery is fully charged. These figures are approximate and will
vary according to the charging and other operating conditions,
such as temperature, humidity, and battery condition.
AVERAGE COMPRESSIONS
CONDUCTOR
#6 Cu / Al
1/0 Cu /Al
4/0 Cu /Al
3.4

SWITCH OPERATIONS

1. The ram advances when the Trigger is depressed and
stops when the Trigger is released.
2. To retract the ram, depress the Release Button. The ram
continues to retract while the Release Button is
depressed.
Work Light
Button
Release
Button
Battery
Charger
PER CHARGE
BAT-144-LI
250
170
125
Trigger
TA04713 A Page 4 of 8