4. Attach the product with the nut.
To attach the product with a Husqvarna
vacuum plate
WARNING:
combination with the vacuum plate when
you drill in walls or ceilings.
WARNING:
be flat and of good quality. The product can
become loose if the vacuum plate cannot
seal fully against the surface.
WARNING:
only recommended together with these
Husqvarna drill motors: DM200, DM220,
DM230, DM280 High speed. Use of other
To do before you operate the product
Read the operator's manual carefully and make sure
that you understand the instructions.
Read the operator's manual for the drill motor
carefully and make sure that you understand the
instructions.
Do the daily maintenance. Refer to
maintenance on page 12 .
To adjust the angle of the drill column
The drill column can be tilted 0–60°.
1341 - 005 - 28.09.2023
Do not use the product in
The support surface must
Use of vacuum plate is

Operation

Daily
drill motors can cause the product to
become loose.
1. Loosen the level adjustment screws. They must be
above the bottom of the vacuum plate.
2. Connect the vacuum hose and start the pump.
WARNING:
must be -0.85 bar to seal the vacuum
plate tightly to the surface.
3. Tighten the level screws until you feel pressure on
the screw.
WARNING:
screws must touch the surface when
when you use the vacuum plate. If not,
the vacuum plate can come loose.
To install the product with an all thread rod
Use an all thread rod to install the product to a wall
or ceiling.
Use an all thread rod when it is not possible to use
an expander bolt.
Use washers and nuts to tighten the all thread rod.
The minimum pressure