3. Reconditioning the battery

Because the battery cell has not been charged when you purchased the battery, the status of "Current Write
Policy" is "Write Through". To see the status on MSM, select the Logical tab in the left frame of the window,
and then select each "Virtual Disk" under the Logical tab. Then select the Properties tab in the right frame of
the window. The battery will execute the following operations to recondition the battery when it is installed or
replaced.
1.
The battery starts charging. The following log is registered in MSM and application log.
Controller ID:x Battery started charging
2.
About a few hours later, the battery finishes charging. The following log is registered to MSM and
application log.
Controller ID:x Battery charge complete
3.
The battery starts discharging to recondition the battery status. The following logs are registered in
MSM and application log.
Controller ID:x Battery relearn pending: Battery is under charge
Controller ID:x Battery is discharging
4.
After several hours, the battery finishes discharging. The following log is registered in MSM and
application log.
Controller ID:x Battery relearn completed
5.
The battery starts charging again. The following log is registered in MSM and application log. If the
battery does not start charging after a while, please reboot the server and confirm if the following log is
registered in MSM or application log.
Controller ID:x Battery started charging
6.
About a few hours later, the battery finishes charging. The following log is registered in MSM and
application log. After these operations, the battery will execute discharging and charging every 30
days.
Controller ID:x Battery charge complete