Download Print this page

Advertisement

Quick Links

HPE ProLiant DL560 Gen11 Server User Guide
HPE ProLiant DL560 Gen11 Server User Guide
Part Number: 30-9E6C3EEB-001b
Published: June 2023
Edition: 1b

Advertisement

loading

Summary of Contents for HP ProLiant DL560 Gen11

  • Page 1 HPE ProLiant DL560 Gen11 Server User Guide HPE ProLiant DL560 Gen11 Server User Guide Part Number: 30-9E6C3EEB-001b Published: June 2023 Edition: 1b...
  • Page 2 HPE ProLiant DL560 Gen11 Server User Guide HPE ProLiant DL560 Gen11 Server User Guide Abstract Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels, and are familiar with the weight and stability precautions for rack installations.
  • Page 3 Table of contents Table of contents Component identification Front panel components iLO Service Port Front panel LEDs and buttons Server UID LED Using the UID button to view the Server Health Summary Front panel LED power fault codes Rear panel components Display device setup Rear panel LEDs System board components...
  • Page 4 Setting up the server Adjusting the server power supply redundancy setting Operational requirements Space and airflow requirements Temperature requirements Power requirements Electrical grounding requirements Rack warnings and cautions Server warnings and cautions Electrostatic discharge Operations Remove the front bezel Power down the server Open the cable management arm Extend the server out of the rack Remove the server from the rack...
  • Page 5 Installing the server into the rack Installing the rack rail hook-and-loop strap Installing the cable management arm Power supply options Hot-plug power supply calculations Power supply warnings and cautions DC power supply warnings and cautions Power supply redundancy Installing an AC power supply Installing a DC power supply Connecting a DC power cable to a DC power source Transceiver option...
  • Page 6 Upgrading from the dual- to quad-processor configuration Processor heatsink assembly option Processor cautions Installing the processor heatsink assembly HPE NS204i Boot Device option Installing the front HPE NS204i Boot Device Installing the rear HPE NS204i Boot Device OCP NIC 3.0 adapter option OCP slot population rules Installing the OCP NIC 3.0 adapter Power distribution board...
  • Page 7 Configuring the server Configuring storage controllers Managing the HPE NS204i Boot Device Deploying an OS Configuring security Optimizing the server Server management Managing Linux-based high performance compute clusters Troubleshooting NMI functionality Troubleshooting resources System battery replacement System battery information Removing and replacing the system battery Safety, warranty, and regulatory information Regulatory information Notices for Eurasian Economic Union...
  • Page 8 HPE NS204i-u Boot Device LED definitions HPE NS204i-u Boot Device LED definitions HPE NS204i Boot Device locations HPE NS204i Boot Device locations Front panel components Front panel components 16 SFF drive configuration 16 SFF drive configuration HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 9 The other side shows the default iLO account information. Depending on the type of drive backplane installed , the server supports SFF SAS, SATA, or U.3 NVMe drives. E3.S drive configuration E3.S drive configuration HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 10 Actions are logged in the iLO event log. The server UID flashes to indicate the Service Port status. You can also retrieve the Service Port status by using a REST client and the iLO RESTful API. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 11 You cannot use the Service Port to boot any device within the server, or the server itself. You cannot access the server by connecting to the Service Port. You cannot access the connected device from the server. Front panel LEDs and buttons Front panel LEDs and buttons HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 12 The UID LED is used to locate a particular server when it is deployed in a dense rack with other equipment. Activating the UID LED helps an on-site technician to quickly identify a server for maintenance tasks. Using the UID button to view the Server Health Summary Using the UID button to view the Server Health Summary HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 13 Power backplane 8 flashes Storage backplane 9 flashes Power supply 10 flashes PCIe expansion cards installed in riser board 11 flashes Chassis 12 flashes GPU card 13 flashes Rear panel components Rear panel components HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 14 The embedded video controller in the iLO 6 chipset does not support dual display or screen extension mode. To enable dual display mode, install a compatible PCIe graphics card that supports this feature in the expansion slot. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 15 4 flashes per sec—iLO manual reboot sequence 8 flashes per sec—iLO manual reboot sequence in progress Deactivated System board components System board components The grayed out components in the system board image are not for use in this server. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 16 HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 17 System maintenance switch Subtopics Subtopics System maintenance switch descriptions System maintenance switch descriptions DIMM label identification DIMM label identification DIMM slot numbering DIMM slot numbering Heatsink and processor socket components Heatsink and processor socket components HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 18 To determine DIMM characteristics, see the label attached to the DIMM. The information in this section helps you to use the label to locate specific information about the DIMM. For more information about product features, specifications, options, configurations, and compatibility, see the HPE DDR5 SmartMemory QuickSpecs: https://www.hpe.com/docs/server-memory https://www.hpe.com/docs/server-memory HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 19 Data width on DRAM x4—4-bit x8—8-bit Memory generation PC5—DDR5 Maximum memory speed 4800 MT/s CAS latency B—42-42-42 B—50-42-42 (for 128 GB and 256 GB capacities) DIMM type R—RDIMM (registered) DIMM slot numbering DIMM slot numbering HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 20 Processor carrier release tabs Bolster plate guide posts Bolster plate Heatsink screws This module consists of the heatsink attached to the processor that is already secured in its carrier. Liquid cooling options Liquid cooling options HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 21 The tubes of the liquid cooling heatsink are prefilled with coolant. In the unlikely event of a spill or leak of this server coolant, follow the recommended procedure in Appendix I: Server coolant spill response of the server maintenance guide: https://www.hpe.com/info/dl560gen11-msg https://www.hpe.com/info/dl560gen11-msg HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 22 Socket 3 MCIO connectors 13–14 (from left to right) x8 SlimSAS ports 1–6 (from right to left) Liquid cooling power connector Subtopics Subtopics Processor mezzanine board DIMM slot numbering Processor mezzanine board DIMM slot numbering HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 23 PCIe5 x8/x16/x8 riser components Item Description Item Description Storage controller backup power connectors PCIe5 x16 (8, 4, 1) slots PCIe5 x16 (16, 8, 4, 1) slot PCIe5 3 x16 riser components PCIe5 3 x16 riser components HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 24 Item Description Item Description Storage controller backup power connectors PCIe5 x16 (16, 8, 4, 1) slots LP SlimSAS connector 1 LP SlimSAS connector 2 PCIe5 slot description PCIe5 slot description HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 25 These numbers correspond to the maximum link bandwidth supported by the slot. Riser slot numbering Riser slot numbering All riser slots are PCIe5 x16 (16, 8, 4, 1) and are rated for a maximum power draw of 75 W each. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 26 Green LED—Managed by the drive itself and indicates the drive activity. SFF basic drive carrier basic drive carrier The SFF basic drive carrier supports hot-plug SAS, SATA, and U.3 PCIe4 NVMe drives . HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 27 EDSFF drive carrier has two LEDs: Amber/blue LED—Managed by the drive backplane in conjunction with the storage controller and is used to indicate drive status. Green LED—Managed by the drive itself and indicates the drive activity. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 28 8 SFF 24G x4 U.3 NVMe / SAS UBM6 BC For more information on the drive backplane description, see Drive backplane naming. 16 SFF + 2 SFF drive bay numbering 16 SFF + 2 SFF drive bay numbering HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 29 Your server might not support all the features listed in this topic. For server-specific support information, see the server guides: Drive backplane support, see Drive bay numbering. Drive backplane cabling, see Storage cabling. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 30 CPU direct attach or tri-mode controller support for x4 U.2 NVMe drives. Fan numbering Fan numbering This server supports two cooling configurations: The server in the air cooling configuration is by default populated by six dual-rotor fans. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 31 These artifacts can include passwords, certificates, and encryption keys. The TPM 2.0 is embedded on the server system board. The TPM 2.0 is supported with specific operating system support such as Microsoft Windows Server 2012 R2 and later. For more HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 32 To help ensure maximum security, observe the following guidelines when retaining the recovery key/password: Always store the recovery key/password in multiple locations. Always store copies of the recovery key/password away from the server. Do not save the recovery key/password on an encrypted drive. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 33 HPE NS204i-u Boot Device components HPE NS204i-u Boot Device components Item Description Item Description Boot device cage M.2 slots Boot device carriers HPE NS204i-u Boot Device LED definitions HPE NS204i-u Boot Device LED definitions HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 34 Flashing green (4 flashes Drive is operating normally and has activity. per second) Drive is not configured by a RAID controller or is a spare drive. HPE NS204i Boot Device NS204i Boot Device locations locations HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 35 Initial system installation Depending on your technical expertise and the complexity of the product, for the initial system installation, select one of the following options: Ordering the HPE Installation Service Setting up the server HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 36 The SPP is also available for download from the SPP download page at https://www.hpe.com/servers/spp/download https://www.hpe.com/servers/spp/download. Verify that your OS or virtualization software is supported: https://www.hpe.com/support/Servers-Certification-Matrices https://www.hpe.com/support/Servers-Certification-Matrices The embedded Intel Virtual RAID on CPU (Intel VROC) provides enterprise-level hybrid RAID support. Note the following information: HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 37 If a DHCP server assigns the IP address, the IP address appears on the boot screen. If a static IP address is assigned, use that IP address. c. Enter the iLO login name and password, and then click Log In. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 38 4. Press F10 to Save or F12 to Save and Exit. Operational requirements Operational requirements When preparing the site and planning the installation for the HPE ProLiant DL560 Gen11 Server, be sure to observe the following general operational requirements: Space and airflow requirements...
  • Page 39 Do not exceed the manufacturer’s TMRA. Power requirements Power requirements Installation of this equipment must comply with local and regional electrical regulations governing the installation of information technology HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 40 Adequately stabilized the rack before extending a component outside the rack. Extend only one component at a time. A rack may become unstable if more than one component is extended. Do not stack anything on top of rail-mounted component or use it as a work surface when extended from the rack. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 41 Do not expose the energy pack to low air pressure as it might lead to explosion or leakage of flammable liquid or gas. Do not expose the energy pack to temperatures higher than 60°C (140°F). After power is disconnected, battery voltage might still be present for 1s to 160s. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 42 This chapter describes the hardware operations carried out prior to and after installing or removing a hardware component, or performing a server maintenance or troubleshooting procedure. Before performing these hardware operations, review the: Rack warnings and cautions Server warnings and cautions HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 43 If you are using the iLO virtual power button to power the server on/off, you do not need to remove the front bezel. Remove the front bezel only if you need to access the front panel components. Procedure Procedure 1. If installed, remove the Kensington security lock. For more information, see the lock documentation. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 44 Before powering down the server for any upgrade or maintenance procedures, perform a backup of critical server data and programs. IMPORTANT: IMPORTANT: When the server is in standby mode, auxiliary power is still being provided to the system. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 45 Before you perform this procedure, review the Rack warnings and cautions. T-25 Torx screwdriver—This tool is required if the shipping screws located inside the chassis ears are secured. About this task About this task HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 46 To reduce the risk of personal injury, be careful when pressing the server rail-release latches. The inner rails could pinch your fingers. Press and hold the rear-end rail-release latches (callout 1), and then slide the server out of the rack until it is fully extended (callout 2). HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 47 Before you perform this procedure, make sure that you have a T-25 Torx screwdriver available. Procedure Procedure 1. Power down the server. 2. If installed, open the cable management arm. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 48 Press and hold the rear-end rail-release latches (callout 1), and then slide the server out of the rack until it is fully extended (callout 2). 6. Slide the server completely out of the rack. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 49 When this happens: The health LED flashes amber. The operating system gracefully shuts down. Procedure Procedure 1. Power down the server. 2. If installed, open the cable management arm. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 50 If necessary, unlock the access panel latch (callout 1). b. To disengage the access panel from the chassis, press the release button and pull up the latch (callouts 2 and 3). c. Lift the access panel (callout 4). HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 51 4. Disconnect all peripheral cables from the server. 5. Do one of the following: Extend the server from the rack . Remove the server from the rack . 6. Remove the access panel . 7. Remove the air baffle. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 52 5. Remove the server from the rack . 6. Place the server on a flat, level work surface. 7. Remove the access panel . 8. Press the buttons to rotate the processor mezzanine tray handle to the fully open position. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 53 11. Remove the processor mezzanine tray from the server. Removing the processor mezzanine tray in the liquid cooling configuration Removing the processor mezzanine tray in the liquid cooling configuration 12. Remove the fan cage groove cover. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 54 13. Loosen the radiator bracket screws. 14. Hold the tray handle and the top radiator with the brackets simultaneously to remove the top processor mezzanine tray from the server. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 55 One person to remove and hold the top radiator with its brackets to keep the coolant tubes out of the fan cage groove, and the other one to remove the fan cage from the server. Procedure Procedure 1. Power down the server. 2. If installed, open the cable management arm. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 56 8. If the server is in the liquid cooling configuration, remove the processor mezzanine tray . 9. If the server is in the liquid cooling configuration, remove and hold the bottom radiator with its brackets gently to keep the coolant tubes out of the fan cage groove. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 57 10. Remove the fan cage: a. Open the fan cage latches (callout 1). b. Remove the fan cage from the server (callout 2). Air cooling fan cage Liquid cooling fan cage HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 58 7. If an expansion card with internal cables is installed on the riser, disconnect all cables from the expansion card. 8. Remove the riser cage. a. Release the half-turn spring latch (callouts 1 and 2). b. Lift the riser cage off the system board (callout 3). HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 59 The riser cage is aligned with the rear chassis. The riser board is firmly seated on the system board. b. Simultaneously push and rotate the half-turn spring latch to 180° (callout 2). c. Close the spring latch (callout 3). HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 60 One person to install the fan cage in the server, and the other one to hold and install the top radiator with its brackets to place the coolant tubes into the fan cage groove. Procedure Procedure 1. Install the fan cage. Air cooling fan cage HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 61 Liquid cooling fan cage 2. If removed, hold and install the bottom radiator with its brackets to place the coolant tubes into the fan cage groove. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 62 5. Install the access panel . 6. Perform the post-installation or maintenance steps required by the procedure that necessitates the removal of the fan cage. Install the processor mezzanine tray Install the processor mezzanine tray Prerequisites Prerequisites HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 63 2. If the server is in the air cooling configuration, install the processor mezzanine tray. 3. Connect all cables to the processor mezzanine board. 4. Press down on the processor mezzanine tray handle until it locks into place. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 64 5. If the server is in the liquid cooling configuration: a. Install the radiator bracket screws. b. Install the fan cage groove cover. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 65 1. Make sure that all internal cables have been properly routed and will not interfere with the air baffle installation. 2. Lower the air baffle into the chassis and make sure that it fits properly into place. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 66 1. With the access panel latch open, insert the guide pin on the chassis through the hole on the bottom side of the latch. 2. Close the access panel latch. The access panel slides to the closed position. 3. Lock the access panel latch. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 67 1. Install the server into the rack: a. Insert the inner rails into the slide rails (callout 1). b. Slide the server into the rack until the chassis ears are flush against the rack posts (callout 2). HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 68 3. Connect all peripheral cables to the server. 4. Connect the power cords: a. Connect each power cord to the server. b. Connect each power cord to the power source. 5. If installed, close the cable management arm. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 69 This chapter provides instructions for installing supported hardware options. To ensure proper server deployment and operation, Hewlett Packard Enterprise recommends installing only HPE‑validated hardware options. To see the list of validated options for this server, see the product QuickSpecs on the HPE ProLiant DL560 Gen11 Server website: https://buy.hpe.com/us/en/p/1014705735 https://buy.hpe.com/us/en/p/1014705735...
  • Page 70 Security passwords including those required for power-on and BIOS admin access, persistent memory, and Server Configuration Lock (for HPE Trusted Supply Chain servers) Server serial number and the product ID iLO-related data—Use the iLO backup and restore function. For more information, see the iLO user guide HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 71 Installing the front bezel option Installing the front bezel option Procedure Procedure 1. Attach the front bezel to the right chassis ear. 2. Press and hold the front bezel release latch. 3. Close the front bezel. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 72 Installing a SAS, SATA or NVMe drive Installing an E3.S drive Installing an E3.S drive Drive installation guidelines Drive installation guidelines Observe the following general guidelines: The system automatically sets all drive numbers. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 73 CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank. Procedure Procedure 1. If installed, remove the front bezel . 2. Remove the drive blank. Retain the blank for future use. 3. Prepare the drive. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 74 To prevent damage, observe antistatic precautions. CAUTION: CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank. Procedure Procedure HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 75 3. Observe the drive LED status and determine if the drive can be removed. 4. Remove the drive blank. Retain the blank for future use. 5. Prepare the drive. 6. Install the drive. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 76 Installing the rack rail hook-and-loop strap Installing the cable management arm Installing the cable management arm Rail identification markers Rail identification markers The rack rail option support is dependent on these two factors: HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 77 To ensure compatibility between the rack rails and the server, verify that the rail number labels on the chassis match the ones stamped on the rails. Rail number labels on the chassis Rail identifier stamps on the short ball-bearing rail Rail identifier stamps on the long ball-bearing rail HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 78 Make sure that the rail option is compatible with the server configuration . Small slotted screwdriver—This tool is required if you intend to install the server in a threaded round-hole rack. About this task About this task HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 79 Be sure to keep the product parallel to the floor when installing the rack. Tilting the product up or down could result in damage to the slides. Procedure Procedure 1. Verify the rail identifiers match on the server and rails. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 80 2. Install the rack rails. For round and square-hole racks For threaded-hole racks HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 81 3. Fully extend the rails to the locked position. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 82 Server warnings and cautions Space and airflow requirements T-25 Torx screwdriver Procedure Procedure 1. Extend the slide rails out on the mounting rails until they hit the internal stops and lock into place. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 83 Slide the server into the rack until the chassis ears are flush against the rack posts (callout 2). 3. Open the chassis ears (callout 1), and then tighten the shipping screws (callout 2). HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 84 Connect each power cord to the server. b. Connect each power cord to the power source. 6. If installed, close the cable management arm. Installing the rack rail hook-and-loop strap Installing the rack rail hook-and-loop strap HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 85 2. (Optional) The CMA retention bracket can be rotated to fit a left- or right-hand CMA operation. Press and hold the rotate mechanism (callout 1), and then rotate the bracket 180° (callout 2). There will be an audible click to indicate that the bracket is locked in its adjusted position. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 86 Insert the outer tab into the mounting rail (callout 2). c. Insert the retention bracket into the opposite mounting rail (callout 3). There will be an audible click to indicate that the tabs and bracket are locked into place. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 87 4. Open the cable clamps. 5. (Optional) If your CMA has cable straps for additional cable strain relief, unwrap the straps. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 88 Otherwise, the cables might snag on other equipment installed in the rack when the server is extended from or returned to the rack. Route the peripheral cables and power cords through the cable clamps and/or straps. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 89 To ensure that the cables and cords are secured properly, slide the chassis in and out of the rack. Make sure that there is no risk of accidental disconnection of the peripheral cables and power cords. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 90 Hot-plug power supply calculations Hot-plug power supply calculations For hot-plug power supply specifications and calculators to determine electrical and heat loading for the server, see the Hewlett Packard Enterprise Power Advisor website (https://www.hpe.com/info/poweradvisor/online https://www.hpe.com/info/poweradvisor/online). HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 91 Two-power supply configuration Two-power supply configuration The server supports 1 + 1 Redundancy in the two-power supply configuration. In this power redundancy, the server will continue to operate if one power supply fails. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 92 In a four-power supply configuration, the server is by default configured for 2 + 2 power redundancy. The power supplies 1–2 (orange), and power supplies 3–4 (blue) are supported horizontally for redundancy. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 93 2. If you are installing a power supply in the power supply bay 2, remove the power supply blank. Retain the blank for future use. 3. Immediately slide the power supply into the bay until it clicks into place. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 94 Connect each power cord to the server. b. Connect each power cord to the power source. 7. Make sure that the power supply LED is green. 8. If installed, close the cable management arm. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 95 (The power cable and lug kit listed below can only be used with the 1600 W -48 VDC power supply.) If you are using an input power cord option, the P22173-B21 HPE 1600 W DC PSU power cable kit can be purchased from an HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 96 CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank. Procedure Procedure 1. Remove the protective cover from the power supply. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 97 2. Remove the ground wire screw (callout 1), and then remove the positive return wire and negative input wire screws (callout 2). 3. Attach the ground wire (green and yellow) to the DC power supply (callout 1) and tighten the screw and washer with 1.47 N-m (13 lbf-in ) (callout 2). HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 98 5. Install the negative input wire (black): a. Insert the negative input wire into the -48V slot on the DC power supply (callout 1). b. Tighten the screw to 0.98 N-m (8.68 lbf-in) (callout 2). HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 99 CAUTION: Avoid tight bend radii to prevent damaging the internal wires of a power cord or a server cable. Never bend CAUTION: power cords and server cables tight enough to cause a crease in the sheathing. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 100 8. If you are installing a power supply in the power supply bay 2, remove the power supply blank. Retain the blank for future use. 9. Immediately slide the power supply into the bay until it clicks into place. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 101 Switching or disconnecting devices should not be in the earthed circuit conductor between the DC source and the point of connection of the earthing electrode conductor. Procedure Procedure 1. Cut the DC power cord ends no shorter than 150 cm (59.06 in). HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 102 When you replace a transceiver with another of a different type, the server might retain selected port-specific configuration settings that were configured for the replaced transceiver. Be sure to validate or reconfigure port settings as required. Installing a transceiver Installing a transceiver HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 103 Before you perform this procedure, make sure that you have a T-10 Torx screwdriver available. Procedure Procedure 1. If installed, remove the front bezel . 2. Power down the server. 3. If installed, open the cable management arm . HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 104 When routing cables, always be sure that the cables are not in a position where they can be pinched or crimped. Route the SID cable through the opening in the front of the server, and then install the SID module. Secure the module using the removed T-10 screw. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 105 23. If removed, install the front bezel . 24. To access the SID, do the following: a. Press and release the panel (callout 1). b. After the display fully ejects, rotate the display to view the LEDs (callout 2). HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 106 2. If installed, remove the front bezel . 3. Power down the server. 4. If installed, open the cable management arm . 5. Remove all power: a. Disconnect each power cord from the power source. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 107 13. (Optional) Install the 2 SFF stacked drive cage in the universal media bay . 14. Install the universal media bay: a. Install the universal media bay in the server (callout 1). b. Install the universal media bay screws (callout 2). HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 108 24. Power up the server . 25. If removed, install the front bezel . Results Results The installation is complete. Optical drive option Optical drive option The server supports a slim-type SATA optical drive. Subtopics Subtopics HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 109 9. Do one of the following: Remove the air baffle . Remove the processor mezzanine tray . 10. Remove the fan cage. 11. Install the universal media bay in the server . 12. Install the optical drive bracket. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 110 13. Remove the optical drive blank from the universal media bay. 14. Install the optical drive in the universal media bay (callout 1), and then install the screw (callout 2). HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 111 2 stacked drive cage To maintain proper system cooling, install the correct fan and heatsink types required for specific drive configurations. For more information, see the product QuickSpecs on the HPE ProLiant DL560 Gen11 Server website: HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 112 9. Do one of the following: Remove the air baffle . Remove the processor mezzanine tray . 10. Remove the fan cage. 11. Remove the drive box blank: a. Remove the drive box blank screws (callout 1). HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 113 Install the drive cage screws (callout 2). 13. Cable the 8 SFF drive cage: Drive power cable Storage controller cable 14. Install the fan cage. 15. Do one of the following: Install the air baffle . HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 114 5. Disconnect all peripheral cables from the server. 6. Remove the server from the rack . 7. Place the server on a flat, level work surface. 8. Remove the access panel . 9. Do one of the following: HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 115 12. Install the E3.S drive cage: a. Install the E3.S drive cage in the server (callout 1). b. Install the drive cage screws (callout 2). 13. Cable the E3.S drive cage: Drive power cable HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 116 Installing the 2 SFF stacked drive cage in the universal media bay Installing the 2 SFF stacked drive cage in the universal media bay 1. Install the grommets onto the underside of the stacked drive cage. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 117 Remove the optical drive tray from universal media bay (callout 2). 3. Remove the 2 SFF drive blank: a. Remove the blank screws (callout 1). b. Remove the drive blank from universal media bay (callout 2). HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 118 Install the stacked drive cage screws (callout 2). 5. Install the optical drive tray: a. Install the optical drive bay on the universal media bay (callout 1). b. Install the optical drive bay screws (callout 2). HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 119 Drive power cable Storage controller cable 18. Connect the universal media bay cables to the system board . 19. Install the fan cage. 20. Do one of the following: Install the air baffle . HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 120 All DIMM slots support HPE DDR5 SmartMemory (RDIMM with ECC, LRDIMM) . DIMM slots on the system board DIMM slots on the system board DIMM slots on the processor mezzanine board DIMM slots on the processor mezzanine board HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 121 Do not touch the components on the sides of the DIMM. Do not touch the connectors on the bottom of the DIMM. Never wrap your fingers around a DIMM. Never bend or flex the DIMM. When installing a DIMM, observe the following: HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 122 Installing a DIMM Prerequisites Prerequisites To meet the system thermal requirements, some DIMMs require specific processors and drive configuration. Review the product QuickSpecs for these requirements on the HPE ProLiant DL560 Gen11 Server website: https://buy.hpe.com/us/en/p/1014705735 https://buy.hpe.com/us/en/p/1014705735 About this task About this task...
  • Page 123 Install the air baffle . Install the processor mezzanine tray . 11. Install the access panel . 12. Installing the server into the rack . 13. Connect all peripheral cables to the server. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 124 Disconnect each power cord from the server. 4. Disconnect all peripheral cables from the server. 5. Remove the server from the rack . 6. Place the server on a flat, level work surface. 7. Remove the access panel . HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 125 Preparing the server for storage controller installation Preparing the server for storage controller installation Installing a type-o storage controller Installing a type-o storage controller Installing a type-p storage controller Installing a type-p storage controller HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 126 2. If installed, open the cable management arm . 3. Remove all power: a. Disconnect each power cord from the power source. b. Disconnect each power cord from the server. 4. Disconnect all peripheral cables from the server. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 127 Slide the controller into the bay until it clicks into place (callout 2). Make sure that the controller is seated firmly in the slot. c. Rotate the locking pin to the close (horizontal) position (callout 3). HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 128 For more information on the controller caching feature, see the controller QuickSpecs on the Hewlett Packard Enterprise website (https://www.hpe.com/info/qs https://www.hpe.com/info/qs). Before you perform this procedure, make sure that you have the following items available: Compatible controller cable T-10 Torx screwdriver HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 129 Install the type-p storage controller (callout 1), and install the screw (callout 2). Make sure that the controller is seated firmly in the slot. b. Close the riser cage latch (callout 3). HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 130 One energy pack supports multiple devices. After it is installed, the status of the energy pack appears in HPE iLO. For more information, see the iLO user guide: https://www.hpe.com/support/ilo6 https://www.hpe.com/support/ilo6 Subtopics Subtopics HPE Smart Storage Battery HPE Smart Storage Battery HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 131 Installing an energy pack Prerequisites Prerequisites Make sure that a compatible type-p storage controller is installed . Make sure that you have the storage controller backup power cable that ships with the storage controller. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 132 Make sure that the energy pack is locked in the retention latch. c. Connect the energy pack cable (callout 3). 11. Connect the storage backup power cable . 12. Install the fan cage. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 133 Prerequisites Prerequisites Depending on the drive configurations in the different cooling configurations, some Ethernet adapters and InfiniBand cards require specific system ambient temperature. Review the product QuickSpecs for these requirements on the HPE ProLiant DL560 Gen11 Server website: https://buy.hpe.com/us/en/p/1014705735 https://buy.hpe.com/us/en/p/1014705735...
  • Page 134 9. (Optional) Install the riser board . 10. If you are installing a low-profile expansion card: a. Remove the half-height bracket from the expansion card. b. Install the full-height bracket on the expansion card. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 135 11. Remove the riser slot blank. 12. Install the expansion card. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 136 In the liquid cooling configuration, the processor mezzanine tray with the liquid cooling options is by default in the server. The processor mezzanine board on the tray has 32 DIMM slots supporting HPE DDR5 SmartMemory (RDIMM with ECC, LRDIMM) . HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 137 Only the server in the air cooling configuration can be upgraded from the dual- to quad-processor configuration. For the processors that support the liquid cooling, quad-processor configuration, see the product QuickSpecs on the HPE ProLiant DL560 Gen11 Server website: https://buy.hpe.com/us/en/p/1014705735 https://buy.hpe.com/us/en/p/1014705735...
  • Page 138 Use a T-30 Torx screwdriver to loosen one pair of diagonally opposite heatsink screws (callouts 1 and 2), and then loosen the other pair of heatsink screws (callouts 3 and 4). 11. Set the anti-tilt wires to the unlocked position. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 139 Installing the standard heatsinks on the system board and the mezzanine tray Installing the standard heatsinks on the system board and the mezzanine tray 13. Remove the protective film from the thermal interface material. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 140 14. Set the anti-tilt wires to the locked position. 15. Attach the heatsink to the processor carrier: a. Align the pin 1 indicator on the processor carrier with that on the heatsink. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 141 16. Verify that the processor is securely latched to the processor carrier. The following illustration calls out the keying feature tabs that secure the processor. Different processor carriers will have these tabs in different locations. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 142 17. Perform the following verification steps: a. Verify that the tabs on the processor carrier are securely latched on the heatsink. b. Verify that the pin 1 indicators on the processor and processor carrier are aligned. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 143 18. Remove the dust cover from the processor socket: a. Press and hold the grip tabs on the dust cover (callout 1). b. Lift the dust cover away from the bolster plate (callout 2). HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 144 The posts are keyed so that the module can only be installed one way. Make sure that the module is properly seated on the bolster plate before securing the screws. d. Set the anti-tilt wires to the locked position. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 145 Use a T-30 Torx screwdriver to tighten one pair of diagonally opposite heatsink screws (callouts 1 to 2), and then tighten the other pair of heatsink screws (callouts 3 to 4). 20. Remove the pass through modules. Front pass through module HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 146 Rear pass through module 21. Install the processor mezzanine tray in the server. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 147 26. Connect all peripheral cables to the server. 27. Connect each power cord to the server. 28. Connect each power cord to the power source. 29. Power up the server . Results Results HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 148 2. If installed, open the cable management arm . 3. Remove all power: a. Disconnect each power cord from the power source. b. Disconnect each power cord from the server. 4. Disconnect all peripheral cables from the server. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 149 Press the buttons to rotate the processor mezzanine tray handle to the fully open position. b. Disconnect all cables from the processor mezzanine board. c. Remove the processor mezzanine tray. 10. Remove the protective film from the thermal interface material. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 150 12. Verify that the processor is securely latched to the processor carrier. The following illustration calls out the keying feature tabs that secure the processor. Different processor carriers will have these tabs in different locations. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 151 Lower the heatsink on the processor carrier until the carrier tabs snap into place. There will be an audible click to indicate that the heatsink is properly latched on the processor carrier. Standard heatsink HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 152 High performance heatsink 14. Perform the following verification steps: a. Verify that the tabs on the processor carrier are securely latched on the heatsink. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 153 Verify that the pin 1 indicators on the processor and processor carrier are aligned. c. Verity that the processor is properly secured by the carrier snaps. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 154 To prevent mechanical damage or depositing oil on your hands or other contaminant to the heatsink contact surface, hold the heatsink only by the edge of its base plate. Do not touch the heatsink fins. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 155 The posts are keyed so that the module can only be installed one way. Make sure that the module is properly seated on the bolster plate before securing the screws. Standard heatsink High performance heatsink HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 156 Use a T-30 Torx screwdriver to tighten one pair of diagonally opposite heatsink screws (callouts 1 to 2), and then tighten the other pair of heatsink screws (callouts 3 to 4). Standard heatsink HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 157 High performance heatsink 17. If removed, do the following: a. Install the processor mezzanine tray. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 158 20. Install the server into the rack . 21. Connect all peripheral cables to the server. 22. Connect each power cord to the server. 23. Connect each power cord to the power source. 24. Power up the server . HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 159 Prerequisites Prerequisites If the server is in the quad-processor configuration, review the product QuickSpecs for specific system operating temperature requirements on the HPE ProLiant DL560 Gen11 Server website: https://buy.hpe.com/us/en/p/1014705735 https://buy.hpe.com/us/en/p/1014705735 Make sure that the server is updated with the latest operating system firmware and drivers.
  • Page 160 Insert the SSD into the M.2 slot at a 45° angle (callout 1). c. Carefully press the SSD down to the horizontal position (callout 2). d. Install the SSD mounting screw (callout 3). HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 161 Make sure that the carrier latch is locked on the boot device cage. Installing the boot device Installing the boot device 4. Power down the server. 5. If installed, open the cable management arm . 6. Remove all power: HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 162 11. Do one of the following: Remove the air baffle . Remove the processor mezzanine tray . 12. Remove the fan cage. 13. Install the boot device on the bracket. Air cooling configuration Liquid cooling configuration HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 163 14. Install the boot device in the server. Air cooling configuration Liquid cooling configuration HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 164 Prerequisites Prerequisites If the server is in the quad-processor configuration, review the product QuickSpecs for special specific system operating temperature requirements on the HPE ProLiant DL560 Gen11 Server website: https://buy.hpe.com/us/en/p/1014705735 https://buy.hpe.com/us/en/p/1014705735 Make sure that the server is updated with the latest operating system firmware and drivers.
  • Page 165 Insert the SSD into the M.2 slot at a 45° angle (callout 1). c. Carefully press the SSD down to the horizontal position (callout 2). d. Install the SSD mounting screw (callout 3). HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 166 Make sure that the carrier latch is locked on the boot device cage. Installing the boot device Installing the boot device 4. Power down the server. 5. If installed, open the cable management arm . 6. Remove all power: HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 167 13. Remove the security cover from the boot device bracket. Retain the screws for the boot device installation. 14. Install the boot device onto the bracket: a. Slide the boot device onto the bracket (callout 1). HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 168 Remove the scrwe and the riser slot blank (callouts 2 and 3). Retain the screw. This screw will be used to secure the boot device. 17. Remove the boot device cover on the top of the riser cage. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 169 20. Connect the boot device signal and power cables to the system board . 21. Install the access panel . 22. Installing the server into the rack . 23. Connect all peripheral cables to the server. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 170 Review the OCP slot population rules . Depending on the drive configurations in the different cooling configurations, some OCP 3.0 adapters require specific system ambient temperature. Review the product QuickSpecs for these requirements on the HPE ProLiant DL560 Gen11 Server website: https://buy.hpe.com/us/en/p/1014705735 https://buy.hpe.com/us/en/p/1014705735...
  • Page 171 Remove the blank screw (callout 1). b. Use a plastic spudger to pry the top side of the blank from the chassis (callout 2). c. Remove the blank (callout 3). Retain the screw and blank for future use. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 172 Results The installation is complete. Power distribution board Power distribution board The power distribution board (PDB) supports the installation of power supplies 3 and 4. Subtopics Subtopics Installing the PDB Installing the PDB HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 173 8. Install the PDB. 9. Install the power supplies 3 and 4 . 10. Install the access panel . 11. Installing the server into the rack . 12. Connect all peripheral cables to the server. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 174 Remove the processor mezzanine tray . 9. Install the chassis intrusion detection switch: a. Insert the switch tab into the chassis slot until the switch clicks into place (callout 1). b. Connect the switch cable (callout 2). HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 175 Install the serial port option to enable communication to physical serial devices. You can also use the serial connection to remotely access the system BIOS and view POST error messages. Subtopics Subtopics Installing the serial port Installing the serial port Installing the serial port Installing the serial port Prerequisites Prerequisites HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 176 9. Remove the serial port blank. Retain the blank for future use. 10. Install the serial port: a. Insert the serial port into the rear panel opening (callout 1). b. Install the hex screws (callout 2). HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 177 Internal USB device options Internal USB device options The server has one internal USB 2.0 port and one USB 3.2 Gen 1 port that you can use to install an internal USB flash media device for: HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 178 13. Connect all peripheral cables to the server. 14. Connect each power cord to the power source. 15. Connect each power cord to the server. 16. Power up the server . Results Results HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 179 Some data cables are prebent. Do not unbend or manipulate the cables. To prevent mechanical damage or depositing oil that is present on your hands, and other contamination, do not touch the ends of the connectors. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 180 Grip the body of the cable connector. Do not pull on the cable itself because this action can damage the internal wires of the cable or the pins on the port. If a cable does not disconnect easily, check for any release latch that must be pressed to disconnect the cable. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 181 P55342-001 (For air cooling configuration only) 8 E3.S NVMe direct attach cable (for dual-processor, air cooling P55368-001 configuration only) 12 E3.S NVMe direct attach cables P55371-001 P59130-001 (For air cooling configuration) P55355-001 (For liquid cooling configuration) HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 182 Energy pack cable 876851-001 P02378-001 Storage controller backup power cable from type-o controllers — Optical drive cable P55376-001 Universal media bay USB 2.0 port cable P55373-001 Universal media bay USB 2.0 / DisplayPort Y-cable P14314-001 HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 183 Power switch module / SID module cable P55374-001 Front I/O cable P43727-001 Internal cabling management Internal cabling management Item Item Description Description Cable guards DIMM guards Processor mezzanine tray support bracket Storage cabling Storage cabling HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 184 Air cooling configuration: Blue Box 1 ports 3–4 x8 SlimSAS ports 7–8 (from P55341-001 bottom to top) on the system board Liquid cooling configuration: P61769-001 HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 185 Box 1 port 1 Socket 2 MCIO connector 2 Option kit: P54801-B21 8 SFF x1 SAS storage controller cabling: Type-o controller in Slot 15 8 SFF x1 SAS storage controller cabling: Type-o controller in Slot 15 HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 186 Type-o storage controller port 2 in Slot 15 Option kit: P61602-B21 8 SFF x1 SAS drive controller cabling: Type-p controller in the primary riser 8 SFF x1 SAS drive controller cabling: Type-p controller in the primary riser HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 187 8 SFF x1 SAS drive controller cabling: Type-p controller in the secondary riser Cable part number Cable part number Color Color From From P55362-001 Orange Box 1 port 1 Secondary type-p storage controller port 2 HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 188 Box 1 port 4 Secondary type-p storage controller port 4 Option kit: P55320-B21 2 stacked drive controller cabling: Type-o controller in Slot 15 2 stacked drive controller cabling: Type-o controller in Slot 15 HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 189 2 stacked drive controller cabling: Type-p controller in the secondary riser Cable part number Cable part number Color Color From From P55362-001 Orange Box 1 port 1 Type-p storage controller port 2 in Slot 15 HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 190 8 SFF x4 NVMe direct attach cabling for the processors 2 and 4 8 SFF x4 NVMe direct attach cabling for the processors 2 and 4 When box 1 is the universal media bay HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 191 Box 2 ports 3–4 x8 SlimSAS ports 5–6 (from P55346-001 bottom to top) on the system board Liquid cooling configuration: P61772-001 Option kit: P55316-B21 Option kit: P61770-B21 When box 1 is the 8 SFF drive cage HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 192 Box 2 port 4 x8 SlimSAS port 1 on the processor mezzanine board Option kit: P58338-B21 8 8 E3.S E3.S NVMe direct attach cabling NVMe direct attach cabling This is for dual-processor, air cooling configuration only HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 193 Cable part number Color Color From From P55368-001 Orange Box 2 ports 1–4 x8 SlimSAS ports 5–8 (from bottom to top) Option kit: P60011-B21 12 E3.S E3.S NVMe direct attach cabling NVMe direct attach cabling HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 194 Type-o storage controller port 1 in Slot 14 Option kit: P60009-B21 8 SFF x2 NVMe drive controller cabling: Type-o controller in Slot 15 8 SFF x2 NVMe drive controller cabling: Type-o controller in Slot 15 HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 195 Slot 15 Option kit: P61602-B21 8 SFF x1 SAS drive controller cabling: Type-p controller in the primary riser 8 SFF x1 SAS drive controller cabling: Type-p controller in the primary riser MR416i-p HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 196 Primary type-p storage controller port 2 Option kit: P55320-B21 8 SFF x1 SAS drive controller cabling: Type-p controller in the secondary riser 8 SFF x1 SAS drive controller cabling: Type-p controller in the secondary riser HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 197 8 SFF x4 NVMe drive controller cabling: Type-p controller in the secondary riser 8 SFF x4 NVMe drive controller cabling: Type-p controller in the secondary riser Two MR416i-p controllers in the secondary riser when the box 1 is the universal media bay HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 198 Blue Box 2 port 2 Secondary type-p storage controller port 4 Gold Box 2 port 3 Secondary type-p storage controller port 1 Pink Box 2 port 4 Secondary type-p storage controller port 2 HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 199 8 SFF x4 NVMe drive controller cabling: Type-o controller in Slot 15 and type-p controller in the secondary riser 8 SFF x4 NVMe drive controller cabling: Type-o controller in Slot 15 and type-p controller in the secondary riser HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 200 2 Option kit: P59142-B21 Option kit: P55320-B21 Drive box 3 cabling Drive box 3 cabling 8 SFF x1 SAS drive: Onboard SATA cabling 8 SFF x1 SAS drive: Onboard SATA cabling HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 201 This is for the dual-processor configuration, air cooling configuration only. Cable part number Cable part number Color Color From From P55350-001 Orange Box 3 ports 1–4 x8 SlimSAS ports 1–4 (from bottom to top) HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 202 Option kit: P58339-B21 8 8 E3.S E3.S NVMe direct attach cabling NVMe direct attach cabling This is for the dual-processor configuration, air cooling configuration only. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 203 Cable part number Color Color From From P55369-001 Orange Box 3 ports 1–4 x8 SlimSAS ports 1–4 (from bottom to top) Option kit: P60013-B21 12 E3.S E3.S NVMe direct attach cabling NVMe direct attach cabling HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 204 Type-o storage controller port 1 in Slot 14 Option kit: P55318-B21 8 SFF x2 NVMe drive controller cabling: Type-o controller in Slot 14 8 SFF x2 NVMe drive controller cabling: Type-o controller in Slot 14 HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 205 Type-o storage controller port 2 in Slot 14 Option kit: P61603-B21 8 SFF x1 SAS drive controller cabling: Type-p controller in the primary riser 8 SFF x1 SAS drive controller cabling: Type-p controller in the primary riser HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 206 Box 3 port 3 Primary type-p storage controller port 1 Pink Box 3 port 4 Primary type-p storage controller port 2 Option kit: P59144-B21 SR932i-p controller in the primary riser ( air cooling configuration) HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 207 Box 3 port 3 Primary type-p storage controller port 3 Pink Box 3 port 4 Primary type-p storage controller port 4 Option kit: P59144-B21 SR932i-p controller in the primary riser ( liquid cooling configuration) HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 208 8 SFF x4 NVMe drive controller cabling: Type-o controller in Slot 14 and type-p controller in the primary riser 8 SFF x4 NVMe drive controller cabling: Type-o controller in Slot 14 and type-p controller in the primary riser HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 209 Drive power cabling Drive power cabling 24 SFF drive power cabling 24 SFF drive power cabling Drive power cables are either preinstalled in the server or structured under the relevant drive cage option kit. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 210 Color Color From From P59131-001 Orange Box 2 power connector Drive box 2 power connector 2 P55372-001 Blue Box 3 power connector Drive box 1 power connector and Drive box 2 power connector HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 211 The location of the storage controller backup power connector on the controller Use the following diagrams for reference only. Storage controller backup power cabling from type-o storage controllers Storage controller backup power cabling from type-o storage controllers HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 212 OCP slot 14 backup power connector Optical drive cabling Optical drive cabling Cable part number Cable part number Color Color From From P55376-001 Orange Universal media bay SATA optical port Option kit: P60500-B21 HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 213 Universal media bay Single port USBs P14314-001 Blue Front DisplayPort/USB 2.0 connector Option kit: P60500-B21 HPE NS204i Boot Device NS204i Boot Device cabling cabling Front HPE Front HPE NS204i Boot Device NS204i Boot Device HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 214 P54092-001 Orange Boot device signal connector PCH LP SlimSAS connector 1 P48956-001 Blue Boot device power connector NS204i-u power connector Option kit: P55549-B21 Rear HPE Rear HPE NS204i Boot Device NS204i Boot Device HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 215 From the OCP NIC 3.0 adapter to the processor 3 or 4 From the OCP NIC 3.0 adapter to the processor 3 or 4 The processor 3 and 4 are located on the processor mezzanine board. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 216 Riser enablement cabling When the PCIe5 3 x16 riser is installed, connecting the riser enablement cables is required to enable all the risers. For the processors 1 and 2 For the processors 1 and 2 HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 217 Socket 1 MCIO connector 2 primary riser Pink LP SlimSAS connector 2 on the Socket 1 MCIO connector 1 primary riser Option kit: P55315-B21 For the processors 3 and 4 For the processors 3 and 4 HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 218 LP SlimSAS connector 1 on the Socket 3 MCIO connector 14 primary riser Pink LP SlimSAS connector 2 on the Socket 3 MCIO connector 13 primary riser Option kit: P55319-B21 Serial port cabling Serial port cabling HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 219 Option kit: P48824-B21 Chassis intrusion detection switch cabling Chassis intrusion detection switch cabling Cable part number Cable part number Color Color From From P47751-001 Orange Chassis intrusion detection Chassis intrusion detection switch switch connector HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 220 Cable part number Color Cable part number Color From From P55374-001 Orange Right chassis ear SID connector Option kit: P54810-B21 Front I/O cabling Front I/O cabling Front I/O cable is preinstalled in the server. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 221 Configuring security Optimizing the server Optimizing the server Server management Server management Managing Linux-based high performance compute clusters Managing Linux-based high performance compute clusters Updating firmware or system ROM Updating firmware or system ROM HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 222 Enable policy-based management of server or server group firmware for distributed server infrastructure https://www.hpe.com/info/com-docs https://www.hpe.com/info/com-docs Monitor server compliance with a configured firmware baseline Receive automatic iLO firmware updates Receive baseline update alerts Configuring the server Configuring the server HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 223 For servers running HPE OneView, do not use another tool, such as iLO, to delete or change certain settings. For more information about using HPE OneView and iLO to manage the same server, see the iLO user guide at https://www.hpe.com/support/ilo6 https://www.hpe.com/support/ilo6. Configuring storage controllers Configuring storage controllers HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 224 HPE Synergy https://www.hpe.com/support/UEFIGen11-UG-en https://www.hpe.com/support/UEFIGen11-UG-en Deploy an OS using iLO virtual media iLO user guide https://www.hpe.com/support/ilo6 https://www.hpe.com/support/ilo6 Deploy an OS using Intelligent Provisioning Intelligent Provisioning user guide https://www.hpe.com/info/intelligentprovisioning/docs https://www.hpe.com/info/intelligentprovisioning/docs Configuring security Configuring security HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 225 HPE iLO https://www.hpe.com/support/ilo6 https://www.hpe.com/support/ilo6 Multiple servers HPE OneView https://www.hpe.com/support/oneview-docs https://www.hpe.com/support/oneview-docs Single or multiple servers HPE GreenLake for Compute Ops Management https://www.hpe.com/info/com-docs https://www.hpe.com/info/com-docs Managing Linux-based high performance compute clusters Managing Linux-based high performance compute clusters HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 226 IML events. To access troubleshooting resources for your product, see the Hewlett Packard Enterprise website Hewlett Packard Enterprise website . System battery replacement System battery replacement HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 227 9. If the expansion card is installed, remove the secondary riser cage. 10. Remove the system battery: a. Use a small flat-bladed, nonconductive tool to press the battery latch (callout 1). b. Remove the system battery from the socket (callout 2). HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 228 17. Connect each power cord to the power source. 18. Power up the server. 19. Properly dispose of the old battery. For more information about proper battery disposal, contact an authorized reseller or an authorized service provider. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 229 Hewlett Packard Enterprise Company, 1701 E Mossy Oaks Road, Spring, TX 77389 U.S. Local representative information Russian: Local representative information Russian: Russia Russia ООО "Хьюлетт Паккард Энтерпрайз", Российская Федерация, 125171, г. Москва, Ленинградское шоссе, HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 230 Ukraine RoHS material content declaration Ukraine RoHS material content declaration Warranty information Warranty information To view the warranty information for your product, see the warranty check tool warranty check tool . Specifications Specifications Subtopics Subtopics HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 231 (2953 ft) to a maximum of 3,050 m (10,000 ft). The approved hardware configurations for this system are listed in the Extended Ambient Temperature Guidelines for Gen11 HPE ProLiant servers: https://www.hpe.com/support/ASHRAEGen11 https://www.hpe.com/support/ASHRAEGen11 Mechanical specifications Mechanical specifications HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 232 HPE 1800-2200 W Flex Slot Titanium Power Supply HPE 1800-2200 W Flex Slot Titanium Power Supply HPE 800 W Flex Slot Platinum Hot-plug Low Halogen Power Supply 800 W Flex Slot Platinum Hot-plug Low Halogen Power Supply HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 233 800 W at 100 VAC to 240 VAC input 800 W at 240 VDC input for China only HPE 1000 W Flex Slot Titanium Hot-plug Power Supply HPE 1000 W Flex Slot Titanium Hot-plug Power Supply HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 234 Rated steady-state power 1600 W at 200 VAC to 240 VAC input 1600 W at 240 VDC input Maximum peak power 2200 W for 1 ms (turbo mode) at 200 VAC to 240 VAC input HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 235 1600 W at -40 VDC to -72 VDC Maximum peak power 1600 W at -40 VDC to -72 VDC HPE 1800-2200 W Flex Slot Titanium Power Supply HPE 1800-2200 W Flex Slot Titanium Power Supply HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 236 Product white papers and analyst reports https://www.hpe.com/us/en/resource-library https://www.hpe.com/us/en/resource-library For additional websites, see Support and other resources. Product websites Product websites HPE ProLiant DL560 Gen11 Server product page https://buy.hpe.com/us/en/p/1014705735 https://buy.hpe.com/us/en/p/1014705735 HPE ProLiant DL560 Gen11 Server user documents https://www.hpe.com/info/DL560Gen11-docs https://www.hpe.com/info/DL560Gen11-docs Support and other resources...
  • Page 237 Support Center More Information on Access to Support Materials page: https://www.hpe.com/support/AccessToSupportMaterials https://www.hpe.com/support/AccessToSupportMaterials IMPORTANT: IMPORTANT: Access to some updates might require product entitlement when accessed through the Hewlett Packard Enterprise Support Center. You must have an HPE Onepass set up with relevant entitlements. HPE ProLiant DL560 Gen11 Server User Guide...
  • Page 238 Feedback button and icons (at the bottom of an opened document) on the Hewlett Packard Enterprise Support Center portal (https://www.hpe.com/support/hpesc https://www.hpe.com/support/hpesc) to send any errors, suggestions, or comments. This process captures all document information. HPE ProLiant DL560 Gen11 Server User Guide...