Philips PM 5132 Instruction Manual page 10

Function generator 01hz-2mhz
Hide thumbs Also See for PM 5132:
Table of Contents

Advertisement

1.2.3.
1.2.4.
1.2.4.1,
risetime, falltime
(squarewave)
overshoot and ringing
(squarewave)
Amplitude response
(sinewave, reference
value = 1k Hz;)
TTL-output
Connection
_ Duty cycle, frequency
Fan out
Frequency control
Internal sweep
Sweep modes
Sweep characteristic
Start frequency
Stop frequency
Sweep period
Sweep contro} elements
<2%
(at max. amplitude, load 50 2)
<0.1 dB in ranges | to V
< 0:3 dB up to 1 MHz
<1
dBinranges | to VII
(at max. amplitude,load 50 Q,
attenuation 0 dB).
BNC socket at the rear side
identical with main output
20 TTL inputs
— single sweep started by a pulse (SWEEP TRIG
INPUT)
— continuous sweep
single sweep
———
continuous sweep
linear
continuously adjustable within the respective frequency
range after the pushbutton STD BY / CONT
is set to
STD BY.
identical to the dial adjustment
50 ms to 100 s, adjustable in three ranges:
—50ms tots
—0,5
sto10s
—5
sto 100s
— pushbutton to start a single sweep
— pushbutton to stop the running sweep immediately
— pushbutton for resetting to f
luring single sweep.