7 Standard Temperature Setting

Step 1 Attach Ohm Meter Probe across both Plug Prongs.
Step 2 Turn the Dial Knob, if the Meter Needle deflect while the Dial Knob is within the Range shown by arrows (A) and (B) then
Iron is Working Normal.
Step 3 If the Meter Needle Deflects before point (A) or after point (B), proceed to step 4.
Step 4 Turn the Dial Knob to "Maximum" Position and Remove Fabric Guide Plate.
(After Removing the Dial Knob the Adjusting Screw can be seen)
Step 5a If the Dial Knob causes the meter to deflect after point (B), turn the Adjusting Screw Anti-Clockwise.