To change the SPM configuration, the user must enter the PROGRAMMING MODE. This can be accomplished
with the motor either off or in the running mode. To enter the PROGRAMMING MODE, the following procedure
must be used:
1. With the display indicating the following, press the GE key (items in bold italics indicate that they should be
blinking on the screen):
Collr-Ring Motor
SPM READY
2. The display should now indicate that the unit is in STAT MODE:
STAT MODE
SCROLL for menus
3. Press the GE key. The display should now indicate that the unit is in PROGRAMMING MODE:
PROGRAMMING MODE
SCROLL PASSWORD
4. Use the
/
PASSWORD: 0000
ENTER to verify
5. The display should now indicate the CONFIGURATIONS menu or the CALIBRATION menu (depending
upon which scroll key was pressed). Use the
CONFIGURATIONS?
ENTER for menus
6. Press the
key to enter the setpoints menu. Once in the CONFIGURATIONS menu, use the
keys to move through the different setpoints.
7. To change a configuration, press the
MOTOR: Collr-Ring
SELECT to modify
8. Once the configuration has been selected, the value of the setpoint should blink. Use the
change the value of the configuration and then press the
change this setpoint once it has been selected, pressing the GE key deselects the setpoint.
MOTOR: Collr-Ring
SCROLL TO CHANGE
9. Additional configurations can be changed using the above procedure. When all setpoint changes have
been accomplished, press the GE Key. This will return the display to the CONFIGURATIONS main menu.
Press the GE key again and the display will ask to verify that changes should be save. Press
the configurations, otherwise press the GE key if you do not want to save the changes.
SAVE CHANGES?
ENTER to save ...
10. Upon pressing the
changes), the display returns to the PROGRAMMING MODE menu. Press the GE key once to go into
TEST MODE and a second time to return to the SPM READY display.
GE Multilin
Courtesy of store.ips.us
keys to change the password and press
key as prompted:
key (to save the setpoint changes) or the GE key (not wanting to save setpoint
SPM Synchronous Motor Protection and Control

4.2.4 CHANGING CONFIGURATIONS

to enter the password.
/
keys to select the CONFIGURATIONS menu.
key to continue. If you choose not to