ELECTRICAL REQUIREMENTS FOR ELECTRIC DRYERS
Review the following options to determine the appropriate electrical connection
for your home:
4-wire receptacle
(NEMA type14-30R)
l fse Ihc instructions at this section if your home has
a 4-wire receptacle (NEMA type 14-30R) and you
will he using a III. listed. 120/240volt minimum.
30 amp. dryer power supply cord.
3-wire receptacle
(NEMA type10-30R)
Use the instructions at this section if your home has
a 3-wire receptacle (NEMA type 10-30R) and you
will lx- using a Ul. listed. 120/240 volt minimum.
30 amp. dryer power supply cord.
4-wire direct
If this type is available at your home, you will be
connecting to a fused disconnect or circuit breaker
x>x
3-wire direct
If this type is available at your home, you will he
connecting to a fused disconnect or circuit breaker
box
• Screw power supply wire to the terminal block.
Colored wire should be connected to same color
screw. Wire color indicated on manual is
connected to the same color screw in block.
Otherwise, excessive current is applied resulting
in damages on product and heating failure.
• Appropriate screwing is essential. Imcomplete
screwing also may cause loose connection or
unscrewing because of excessive screw
abrasion.
• Loose screwing may cause connection error,
which result in death, fire or serious injury.
4-wire connection : Direct wire
Important: Grounding through the neutral conductor
is prohibited for (I) new branch-circuit installations.
(2) mobile homes, and (3) recreational vehicles, and
(4) areas where local codes prohibit grounding through
the neutral conductor.
Prepare minimum 5ft( 1.52m) of length in order for
dryer to be replaced.
First, peel 5 inch (12.7cm) of covering material from end.
Make a 5 inch of ground wire bared. After cutting 1 '/>
inch (3.8cm) from 3 other wires, peel insulation back
I inch (2.5cm). Make ends of 3 w ires a hook shape.
Then, put the hooked shape end of the wire under the
screw of the terminal blockdiooked end facing rightward)
and pinch the hook together and screw tightly.
1. Connect neutral wire( white) of power cord to center
terminal block screw.
2. Connect red and black wire to llte left and right
terminal block screws.
3. Connect ground w ire(green) of power cord to external
ground screw and move neutral ground wire of
appliance and connect it to center screw.
4. Make sure that the strain relief screw is tightened,
and be sure that all terminal block nuts are on light and
power cord is in right position.
Center terminal block
screw(silver)
Neutral grounding
wire(whlte)
Neutral wire
(white or center wire)
Strain relief
Green wire of power cord
External ground connector