ABB Eden OSSD Product Manual page 27

Coded non-contact safety sensor
Hide thumbs Also See for Eden OSSD:
Table of Contents

Advertisement

Information for use in USA / Canada
Enclosure
Intended use
Power source
Cable assemblies
Conductor size
Directives / Harmonized Standards
EN 61508:2010
EN 62061:2021
EN ISO 13849-1:2015
EN ISO 14119:2013
Certificates
2TLC172272M0201
Rev.H
Type 1, 4, 4x
Applications according to NFPA 79
Only suitable for use in a limited voltage / current circuitry.
The limited voltage / current source must comply with one of the
following:
a) An isolating device such that the maximum open circuit voltage
potential available to the circuit is not more than +24 VDC and
the current is limited to a value not exceeding 8 A measured after
1 min of operation.
or
b) A suitable isolating source in conjunction with a fuse in
accordance with UL248. The fuse shall be rated max. 4 A and be
installed in the +24 VDC power supply to the device to limit the
available current.
Any listed (CYJV/7), M12: 4-pin, 5-pin, or 8-pin A-coding mating
connector. Cord provided shall be 24 AWG (0.2 mm
end is provided with leads for connection to the source, 30 AWG (0.05
2
mm
) minimum when connectors are provided on both ends.
Maximum ampere ratings of the overcurrent protection:
2
AWG
(mm
)
Ampere
22
(0.32)
3
24
(0.20)
2
26
(0.13)
1
28
(0.08)
0.8
30
(0.05)
0.5
-9
SIL3, PFH
= 4.5 x 10
D
SIL3
PL e, category 4
Type 4, high level coded, (Eva Unique code)
Type 4, low level coded, (Eva General code)
TÜV Süd, cULus
2
) minimum when one
27