Download Print this page

JVC RM-P200 Service Manual page 13

Remote control unit

Advertisement

MODE Switch
"RM"
rap aeseuesdsied VIDEO
PICTURE
LEVEL
. To compensate
for attenuation
due to the camera cable
length.
@ Set the LENGTH
switch @ to the nearest value of the
camera cable length being used.
@ Set the FINE and GAIN controls © to the center.
2. Set the output MODE
select switch © to "BARS" to
output color bars.
3. Connect a color monitor TV to the COMPOSITE
VIDEO
QUT connector and adjust the FINE and GAIN controls.
When a vectorscope or waveform monitor is connected to the
COMPOSITE
VIDEO
OUTPUT,
more accurate adjustment is
possible.
—_——— VIDEO OUTPUT:
RYR-Y
GIy
8/B-Y
@
©©©©
COMPOSITE VIDEO ==
LY
)
Color monitor
FINE:
Fine control for chroma level.
GAIN: Gain control for luminance level.
4. Set the output MODE select switch © to "CAM".
EA ADJUSTING
WHITE/BLACK
BALANCE
@
Ina studio with 3200 K lighting, proceed as follows:
Shoota
gray scale pattern, lit with approx. 3000 lux, to full
frame in the monitor screen.
Auto Adjustment (Auto setup and Auto white)
1. With the WHITE BALANCE switch ©) , select either of
the memories
("AUTO
1" or "AUTO 2") to hold a white
balance setting.
3. Set the filter turret according to the illumination of the
object.
4. Switch on the power of the camera and RM-P200.
IRIS MODE Switch
FILTER
OPERATE Switch
"ON/ST-BY"
RM-P200
REMOTE
CONTROL
UNIT
2. Press the AUTO SET switch © upward to the "AUTO
SET" position (non-locked).
©@ For auto white balance adjustment, press the switch and
release it within one second.
®
For auto setup adjustment, hold the switch pressed for
longer than one second.
3. The lamp above the switch lights, and the auto function
starts operating.
4. On normal completion of the operation, the lamp will go
out.
Manual adjustment
© Apply
the output
video signal (composite video) of this
unit to an oscilloscope or a waveform monitor, and adjust
while observing the waveforms.
1. Set the AUTO SET switch © to "MANUAL".
2. Adjust the waveform with the R and B GAIN controls ©.
R varies the red channel gain, and B varies the blue channel
gain. Adjust the waveform so that the carrier leakage of
white is minimum.
Minimum
carrier leakage
Notes:
@
Readjust the auto-set every time the light source changes.
@ When the lamp above the switch blinks after pressing the
AUTO SET switch, this shows that automatic adjustment is
not possible. The cause of automatic adjustment error will
be indicated
in the camera's
viewfinder.
So remove
the
cause, and perform the auto setup again. (For display in-
dications, refer to the instructions of the camera.)

Advertisement

loading