JVC RM-P200 Service Manual page 5

Remote control unit

Advertisement

(4} As shown
in Fig. 6, use the crimping tool to crimp the
metal sleeve at the center position. Be sure to crimp fully
to the complete closure of the tool.
Crimping tool
e@ Safety Check after Servicing
Examine the area surrounding the repaired location for damage or deterioration. Observe that screws, parts and wires have been returned
to original positions, Afterwards, perform the following tests and confirm the specified values in order to verify compliance with safety
standards.
(5) Check the four points noted in Fig. 7.
Crimped at approx. center
of metal sleeve
Conductors extended
Not easily pulled free
ae
Wire insulation recessed more than 4 mm
Fig. 7
1.
Insulation resistance test
Confirm
the specified
insulation
resistance
or greater between
power cord piug prongs and externally exposed
parts of the set
(RF terminals, antenna terminals, video and audio input and out-
put
terminals,
microphone
jacks,
earphone
jacks,
etc.).
See
table below.
2. Dielectric strength test
Confirm
specified dielectric strength or greater between power
cord
plug prongs and exposed accessible parts of the set (RF
terminals, antenna terminals, video and audio input and output
terminals,
microphone
jacks, earphone
jacks, etc.). See table
below.
3. Clearance distance
When
replacing primary circuit components,
confirm
specified
clearance distance (d), (d') between soldered terminals, and bet-
ween
terminals and surrounding metallic parts. See table below.
Chassis
AC Line Vo!tage
110 to 130 V
USA & Canada
4
Insulation Resistance
2 1 m&Q/500 V DC
. Leakage current test
Confirm
specified or lower
leakage current
between
B (earth
ground, power cord plug prongs) and externally exposed accessi-
ble
parts
(RF
terminals,
antenna
terminals,
video
and
audio
input and
output
terminals,
microphone
jacks, earphone jacks,
etc.).
Measuring Method: (Power ON)
Insert load Z between B (earth ground, power cord plug prongs)
and exposed accessible parts. Use an AC voltmeter to measure
across both terminals of load Z. See figure and following table.
Exposed accessible part
AC voitmeter
(high impedance)
B
Earth ground,
power cord plug prongs
Fig. 9
Dielectric Strength
Clearance Distance (d), (d')
1 kV 1 minute
900 V 1 minute
3.2 mm
+
*110 to 130 V
200 to 240 V
Europe
IV
Australia
10 m2/500 V DOC
6 mm (d)
8 mm ({d')
(a: Power cord)
WIV
Flv HIV
4kV 1 minute
a
er
a)
110 to 130 V
USA & Canada
Ratings for selected areas
AC Line Voltage
Region
Load Z
Leakage Current (i)
Earth Ground (b) to:
ae |
aes
es
100 V
Japan
Bae
i
£1mArms
Exposed accessible parts
1.5 kQ
i
$0.5 mArms
Exposed accessible parts
nS OCA
peak
Antenna earth terminals
.
t
110 to 130 V
Europe
2kQ
i<2mAdc
220 to 240 V
Australia
om—"WWhn—0
|
i S$ 0.7 mA peak
,
1
,
Other terminals
50 kL
i<2mAdc
oe en
zal
Table 2
Leakage current ratings for se
I
ected areas