6.
TROUBLESHOOTING GUIDE
SYMPTOM
Pump does not reach required
pressure
Pressure drops during use
Pump noisy
Presence of water in oil
Oil leaks
Motor does not start when
switched on
Motor hums but does not start
when switched on
Water dripping from pump
The motor stops
Fluctuating pressure
7.
DECLARATION OF CONFORMITY
Declaration of Conformity We, the sole importer into the UK of Sealey Power Products, declare that the products listed below are in
conformity with the following standards and directives.
Pressure Washers
Models PC2100.V2 & PC2100PLUS
73/23/EEC Low Voltage Directive
89/336/EEC EMC Directive
NOTE:
It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No responsibility is accepted for incorrect use of this equipment.
WARRANTY: Guarantee is 12 months from purchase, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
01284 757500
REASON(S)
Nozzle incorrect or worn
Dirty filter
Air being sucked into the system
Water pressure low
Worn piston packing
Valves dirty, worn or stuck
Valves dirty or worn
Nozzle worn or blocked
Unloader valve packing worn
Worn piston packing
Dirty filter
Water too hot
Pump sucking air
Valves dirty or worn
Worn bearings
Water too hot
Dirty filter
High humidity in air
Piston packing and oil seal worn
Oil seals worn
Plug not connected
No electrical power
Unsuitable mains voltage
Motor/pump stuck
Pump frozen
Incorrect extension cable
Piston packings worn
Piston guide O-ring worn
Tripped thermal overload due to
overheating
Valves worn, dirty or stuck
Pump sucking air
Worn piston packing
Dirty filter
Sole U.K. Distributor, Sealey Group,
Bury St. Edmunds, Suffolk.
01284 703534
REMEDY
Replace the nozzle.
Clean or replace filter.
Check that hoses and fittings are air tight.
Check that hoses/fittings are water tight and tap is fully open.
Contact Authorised Service Agent.
Contact Authorised Service Agent.
.
Contact Authorised Service Agent
Replace the nozzle.
Contact Authorised Service Agent.
Contact Authorised Service Agent.
Clean or replace.
Reduce temperature.
Check that hoses and fittings are air tight.
Contact Authorised Service Agent.
Contact Authorised Service Agent.
Reduce temperature.
Clean or replace.
Check and replace oil twice as often.
Contact Authorised Service Agent.
Contact Authorised Service Agent.
Check plug connections and mains power supply is active.
Check for adequate power supply and cable condition.
Check by turning motor manually (see Section 5).
If jammed return to your Sealey dealer.
Leave unit to thaw naturally. The pressure washer should be
protected from the threat of freezing. Extensive pump damage
could otherwise occur (see end of Section 4).
Use a suitable extension cable. See Section 1 Elect. Safety.
Contact Authorised Service Agent.
Contact Authorised Service Agent.
Check that the mains voltage matches the specifications.
Switch off the motor and let machine cool for 5 minutes.
Contact Authorised Service Agent.
Check that hoses and fittings are air tight.
Contact Authorised Service Agent.
Check and clean.
The construction files for these products are held by the Manufacturer and
may be inspected, by a national authority, upon request to Jack Sealey Ltd.
Signed by Mark Sweetman
For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products.
sales@sealey.co.uk
e-mail
24th February 2003