Kenwood FG-273 Instruction Manual page 11

Function generator
Hide thumbs Also See for FG-273:
Table of Contents

Advertisement

@) OFFSET/PULL
ADJ Control
Pulling this knob admixes
DC voltage with output signal.
Clockwise rotation admixes positive voltage.
Counterclockwise
rotation admixes negative voltage.
Fig. 3 iillustrates several types of waveform
with the OFFSET
knob pulled and 50—ohm
load connected.
Zero DC offset at max. signal level
Offset limit for non-—clipping signal
Positive DC offset
Negative DC offset
Excessive offset
5V
Positive DC offset
Negative DC offset
Fig.3
Application Example of DC Offset
11