SPECIFICATIONS
<FREQUENCY
CHARACTERISTICS >
GENERAL
Output Waveform
« « « « Sine wave, square wave,
triang! wave, pulse wave, TTL
/CMOS~-level square wave, &
ramp wave
Oscillation Frequency Range « * 0.02 Hz to 2 MHz
7 ranges (1/10/100/1k/10k/
100k /1M)
Frequency Accuracy (1) « *Max. + 1/4 digits (Digital
display to output frequency )
Frequency Accuracy (2) * «+ 5% of full scale (0.2H to
2MHz) ( Frequency dial to
output frequency )
External Frequency Control ( VCF)
Input Voltage
+ * « « * 0 to +10 ; frequency
increases with positive
voltage, max. + 20 V (DC +
AC peak )
Frequency Variable Range
« * *
1000: 1 or more
Symmetry
Variable Range
« * * *
1:1 to 40:1
or more
DC Offset > > © ¢ «© ©
£10V (open circuit)
+5V
(into 500)
continuous variable
Polarity
* * * © © © ©
Inverted or non—inverted
SINE
WAVE
Distortion
* * * * * *
1% or less (10 Hz to 100 kHz)
Output Frequency Response
* * * Within + 1.0 dB up to
100 kHz (into 500 , at max.
output )
Output
* * ¢ © ¢ © © © Variable
SQUARE
WAVE
Symmetry
« « « * © °* 3%
or fess (at 100 Hz)
Rise/ Fall Time
* * « * 100 ns or less (at max. output
level )
Output
* « ¢ * * « « « Variable
TRIANGL
WAVE
Linearity
«+ * * * ¢ ¢ © 1% or less (at 100 Hz)
Output
* * * ¢ ¢ ¢ « « Variable