11.4 Cooling suction pressure curves
outdoor temp.
(humidity 46%)
DB/WB
10℃
15℃
20℃
25℃
30℃
35℃
38℃
40℃
43℃
1750
1550
1350
1150
950
750
550
350
cooling suction pressure.table
21/15℃
906
915
924
973
1024
1035
1089
1198
1318
cooling suction pressure and temp.curves
10℃ 15℃ 20℃ 25℃ 30℃ 35℃ 38℃ 40℃ 43℃
performance curves
indoor temp.
27/19℃
1060
1071
1093
1104
1162
1174
1210
1331
1437
outdoor temp.(DB/WB)
51
Performance and curves diagrams
35/24℃
1232
1244
1257
1283
1295
1364
1392
1531
1668
21/15℃
27/19℃
35/24℃