Page 2
Information in this document is subject to change without notice. Reproduction in any manner whatsoever, without the written permission of D-Link Corporation, is strictly forbidden. Trademarks used in this text: D-Link and the D-LINK logo are trademarks of D-Link Corporation; Microsoft and Windows are registered trademarks of Microsoft Corporation.
Page 3
For AC and DC input: 30W per each PoE port, total: 740W maximum (for DGS-3130-30PS & DGS-3130-54PS) To reduce potential safety issues, only the AC adapter purchased as an accessory from “D-Link”, or “agency” should be used with the product for further information.
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Intended Readers The DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide contains detailed information about the hardware specifications of the switches in this series. It also contains brief information on how to configure and manage a switch in this series.
Page 5
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide • The product has been dropped or damaged. • The product does not operate correctly when the operating instructions are correctly followed. General safety cautions: • Keep the system away from radiators and heat sources. Also, do not block cooling vents.
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide General Precautions for Rack-Mountable Products Please pay careful attention to the following precautions concerning rack stability and safety. Systems are considered to be components in a rack. Thus, a component refers to any system, as well as to various peripherals or supporting...
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Table of Contents Intended Readers ................................ 4 Typographical Conventions ............................4 Notes and Cautions ..............................4 Safety Instructions ............................... 4 Safety Cautions ..............................4 General Precautions for Rack-Mountable Products ....................6 Protecting Against Electrostatic Discharge ........................
Page 8
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Installing the Redundant Power Supply (RPS) ......................35 DPS-500A Series Redundant Power Supply Unit ....................36 Installing the RPS into a Rack-mount Chassis ......................36 DPS-800 Rack-mount Chassis ..........................36 DPS-700 ................................
Features Switch Description The D-Link DGS-3130 Series is a high performance member of the D-Link Layer 3 switch family. Ranging from 10/100/1000 Mbps edge switches to core Gigabit switches, the switch family has been future-proof designed to provide fault tolerance, flexibility, port density, robust security, and maximum throughput with a user-friendly management interface for the networking professional.
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Features This switch is packed with an abundance of networking features that span inside and outside of the traditional Layer 3 framework. The list below highlights the significant protocols and features supported by this switch.
Page 11
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide ® • Microsoft NAP Support (IPv4/IPv6) • Cable Diagnostics • 802.3ah Ethernet Link OAM • 802.1ag Connectivity Fault Management (CFM) • Y.1731 OAM • Optical Transceiver Digital Diagnostic Monitoring (DDM) •...
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide 2. Hardware Components This chapter describes the front, rear, and side panel components of all switches in the series. DGS-3130-30TS Switch DGS-3130-30S Switch DGS-3130-30PS Switch DGS-3130-54TS Switch DGS-3130-54S Switch DGS-3130-54PS Switch...
Page 13
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Figure 2-2 LED indicators for the DGS-3130-30TS Description Power This LED will light solid green after the Switch has been powered on successfully. This LED will be off when the Switch is no longer receiving power (i.e. powered off).
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Description Stack ID This 7-segment LED can display numbers from 1 to 9 and the following letters H, h, E, and G. The stacking ID (1 to 9) can be assigned manually by the user or automatically by the system.
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Figure 2-4 Side panels of the DGS-3130-30TS DGS-3130-30S Switch Front Panel Components The front panel of DGS-3130-30S features a variety of LED indicators and ports. Figure 2-5 Front panel view of the DGS-3130-30S Ports that can be found on the front panel of this switch are listed in the table below.
Page 16
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Figure 2-6 LED indicators for the DGS-3130-30S Description Power This LED will light solid green after the Switch has been powered on successfully. This LED will be off when the Switch is no longer receiving power (i.e. powered off).
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Description when a 10 Gbps port is active or blink amber when a 1 Gbps port is active. The LED will be off when there is no link or activity.
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Figure 2-8 Side panels of the DGS-3130-30S DGS-3130-30PS Switch Front Panel Components The front panel of DGS-3130-30PS features a variety of LED indicators and ports. Figure 2-9 Front panel view of the DGS-3130-30PS Ports that can be found on the front panel of this switch are listed in the table below.
Page 19
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Figure 2-10 LED indicators for the DGS-3130-30PS Description Power This LED will light solid green after the Switch has been powered on successfully. This LED will be off when the Switch is no longer receiving power (i.e. powered off).
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Description The LED at the right side indicates the status of PoE. When this light is on with a solid green light, it means that the corresponding ports are feeding power to the PoE devices plugged in.
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Side Panel Components The side panels of this switch contain heat vents, fans, and rack-mounting screw holes. The heat vents are used to dissipate internal heat and facilitate internal air circulation. Do not block these openings. Leave at least 4 inches of space at the sides of the Switch for proper ventilation.
Page 22
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Figure 2-14 LED indicators for the DGS-3130-54TS Description Power This LED will light solid green after the Switch has been powered on successfully. This LED will be off when the Switch is no longer receiving power (i.e. powered off).
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Description The letter ‘H’ will be displayed if this switch is the master switch in the stack. The letter ‘h’ will be displayed if this switch is the backup master switch in the stack.
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Side Panel Components The side panels of this switch contain heat vents, fans, and rack-mounting screw holes. The heat vents are used to dissipate internal heat and facilitate internal air circulation. Do not block these openings. Leave at least 4 inches of space at the sides of the Switch for proper ventilation.
Page 25
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Figure 2-18 LED indicators for the DGS-3130-54S Description Power This LED will light solid green after the Switch has been powered on successfully. This LED will be off when the Switch is no longer receiving power (i.e. powered off).
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Description when a 10 Gbps port is active or blink amber when a 1 Gbps port is active. The LED will be off when there is no link or activity.
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Side Panel Components The side panels of this switch contain heat vents, fans, and rack-mounting screw holes. The heat vents are used to dissipate internal heat and facilitate internal air circulation. Do not block these openings. Leave at least 4 inches of space at the sides of the Switch for proper ventilation.
Page 28
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Figure 2-22 LED indicators for the DGS-3130-54PS Description Power This LED will light solid green after the Switch has been powered on successfully. This LED will be off when the Switch is no longer receiving power (i.e. powered off).
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Description that the port is in an error condition state. When this light is off, it means that the ports are not supplying power to the devices plugged into the ports.
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Component Description speed. This port can be used to configure the Switch without being connected to the network. Console (RJ45) The RJ45 console port can be used to connect to the Command Line Interface (CLI) of the Switch for configuration, management, and monitoring.
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide 3. Installation Installation Guidelines Installing the Switch without a Rack Installing the Switch in a Standard 19" Rack Installing Transceivers into the Transceiver Ports Power On (AC Power) Installing the Redundant Power Supply (RPS)
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Installing the Switch in a Standard 19" Rack This section is used to guide the user through installing the Switch into a switch rack. The Switch can be mounted in a standard 19"(1U) rack using the provided mounting brackets.
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Figure 3-4 Inserting transceivers into the transceiver ports The SFP+ ports also support other transceiver form factors like SFP and SFP+ transceivers. A complete list of SFP/SFP+ transceivers, compatible with this switch, can be found the SFP Ports and SFP+ Ports sections in Appendix A - Technical Specifications at the end of this document.
Page 34
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Figure 3-5 Insert Tie Wrap into the Switch 2. Plug the AC power cord into the power socket of the Switch. Figure 3-6 Connect the power cord to the Switch 3.
Installing the Redundant Power Supply (RPS) The Redundant Power Supply (RPS) is designed to conform to the wattage requirements of D-Link’s Ethernet and Gigabit switches. It is an external RPS unit enclosed in solid metal case with sockets to connect AC or DC power sources on one end, and to connect to a switch’s internal power supply on the other end.
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide DPS-500A Series Redundant Power Supply Unit This RPS (DPS-500A) can be connected to the Switch’s RPS port using a 14-pin DC power cable. A standard, three- pronged AC power cable connects the RPS to the main power source.
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Figure 3–11 Install the DPS-500A in the DPS-800 The DPS-800 can be mounted into a standard 19" rack, as shown below. Figure 3–12 Install the DPS-800 in an Equipment Rack DPS-700 The DPS-700 is connected to the Master Switch using a 22-pin DC power cable.
Page 38
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Figure 3–13 Front view of the DPS-700 1. Insert one end of the 22-pin DC power cable into the receptacle on the Switch and the other end into the Redundant Power Supply unit.
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide 4. Switch Connections Switch to an End Node Switch to Another Switch Switch Stacking Switch to a Server Switch to an End Node An end node is a generic name for edge networking devices that will be connected to this switch. Typical examples of end nodes are Personal Computers (PCs), Notebooks, Access Points, Print Servers, VoIP Phones and more.
Stacking Cost – Physical stacking number in a stack is limited by stacking cost or maximum stacking device number. In DGS-3130 series, the total stacking cost is 12 and the maximum stacking device number is 9. DGS-3130-30TS/30S/30PS model consumes one stacking cost and DGS-3130-54TS/54S/54PS consumes two stacking costs in a stack.
Page 41
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide The figure below illustrates how switches can be stacked in a Duplex Chain formation using RJ45 cables, optical fiber cables connected to SFP+ transceivers or DAC with SFP+ connectors where the 2-port or 4-port stacking configuration is used.
Page 45
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide The figure below illustrates how switches can be stacked in a Duplex Ring formation using RJ45 cables, optical fiber cables connected to SFP+ transceivers or DAC with SFP+ connectors where the 2-port or 4-port stacking configuration is used.
Page 47
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Figure 4-9 4-port Duplex Ring stacking topology (10GBase-T and SFP+ ports)
Page 48
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Figure 4-10 4-port Duplex Ring stacking topology (SFP+ ports) NOTE: When 4-port duplex ring with 10GBase-T and SFP+ port topology is used and odd number switches are in one stack, one of the switch in stack should be set as 4-port-SFP+ mode.
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Switch to a Server The Switch is ideal for connecting to a network backbone, server, or server farm. The RJ45 ports operate at a speed of 10/100/1000 Mbps. The SFP ports operate at a speed of 100/1000 Mbps. The SFP+ ports operate at a speed of 1/10 Gbps.
Switch. Most of the features available through the CLI can be accessed through the Web UI. Web browsers like Microsoft’s Internet Explorer, Mozilla Firefox, or Google Chrome can be used. For more detailed information about the Web UI, refer to the DGS-3130 Series Web UI Reference Guide. Connecting to the Console Port The front/rear panel of the Switch provides an RJ45 console port to connect a remote system for monitoring and configuring the Switch.
Page 51
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide To configure the terminal emulation software as follows: • Select the appropriate serial port (COM1 or COM2). • Set the data rate to 115200 baud. • Set the data format to 8 data bits, 1 stop bit, and no parity.
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Connecting to the Switch for the First Time The Switch supports user-based security that can prevent unauthorized users from accessing the Switch or changing its configuration. This section will explain how to log into the Switch’s Command Line Interface via the out-of-band console connection.
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide NOTE: Passwords are case sensitive. Usernames can be up to 32 characters in length. Passwords can be up to 32 plain-text characters in length. Configuring the IP Address Each switch must be assigned its own in-band IP Address, which is used for communication with an SNMP network manager or other TCP/IP applications.
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Connecting using SNMP The Simple Network Management Protocol (SNMP) is an OSI Layer 7 (Application Layer) protocol designed specifically for managing and monitoring network devices. SNMP enables network management stations to read and modify the settings of gateways, routers, switches, and other network devices.
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide 6. Web-based Switch Configuration Introduction Logging into the Web UI Web User Interface (Web UI) Introduction Most software functions of the Switch can be managed, configured, and monitored via the embedded HTML Web UI.
Switch. This area displays the Switch’s ports and expansion modules. It also shows port activity based on a specific mode. Some management functions, including port monitoring, are accessible from here. Click the D-Link logo to go to the D-Link website.
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Web Pages In area 2, mentioned above, the following main folders will be available for selecting. Folder Name Description System Features regarding the Switch’s configuration can be viewed and configured in this folder.
Page 61
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Location Color Status Description LED Per Link/Act/Speed Green Light on (Solid) When there is a connection (or link) to a 10/100/1000 Mode 1000 Mbps Ethernet device on any of the...
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Appendix B - Cables and Connectors Ethernet Cable When connecting the Switch to another switch, a bridge or hub, a straight-through Cat5/5e/6a/7 cable is necessary. Please review these products for matching cable pin assignment.
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Console Cable (RJ45 to RS-232) A console cable is used to connect to the RJ45 console port of the Switch to access the command line interface. The following diagram and table show the standard RJ45 to RS-232 cable and pin assignments.
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Redundant Power Supply (RPS) Cable When connecting the Switch to a Redundant Power Supply, an RPS cable is necessary. Please review this product for matching cable pins. The following diagram and table show the standard RPS connector and its pin assignments.
The customer must submit with the product as part of the claim a written description of the Hardware defect or Software nonconformance in • sufficient detail to allow D-Link to confirm the same, along with proof of purchase of the product (such as a copy of the dated purchase invoice for the product).
Page 69
SERVICE) RESULTING FROM THE USE OF THE PRODUCT, RELATING TO WARRANTY SERVICE, OR ARISING OUT OF ANY BREACH OF THIS WARRANTY, EVEN IF D-LINK HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE SOLE REMEDY FOR A BREACH OF THE FOREGOING WARRANTY IS REPAIR, REPLACEMENT OR REFUND OF THE DEFECTIVE OR NON-CONFORMING PRODUCT. THE MAXIMUM LIABILITY OF D-LINK UNDER THIS WARRANTY IS LIMITED TO THE PURCHASE PRICE OF THE PRODUCT COVERED BY THE WARRANTY.
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Technical Support U.S. and Canadian customers This guide is only for initial configuration. Please refer to the user manual to learn more or visit http://www.mydlink.com for more information. Also feel free to contact us. U.S. and Canadian customers can contact D-Link Technical Support through our website.
Page 71
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Europe customers TECHNICAL SUPPORT TECHNISCHE UNTERSTÜTZUNG ASSISTANCE TECHNIQUE ASISTENCIA TÉCNICA SUPPORTO TECNICO TECHNISCHE ONDERSTEUNING POMOC TECHNICZNA TECHNICKÁ PODPORA TECHNIKAI TÁMOGATÁS TEKNISK STØTTE TEKNISK SUPPORT eu.dlink.com/support TEKNINEN TUKI TEKNISK SUPPORT ASSISTÊNCIA TÉCNICA ΤΕΧΝΙΚΉ...
Page 72
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Australia: Tel: 1300-700-100 24/7 Technical Support Web: http://www.dlink.com.au E-mail: support@dlink.com.au India: Tel: +91-832-2856000 or 1860-233-3999 Web: www.dlink.co.in E-Mail: helpdesk@in.dlink.com Singapore, Thailand, Indonesia, Malaysia, Philippines, Vietnam: Singapore - www.dlink.com.sg Thailand - www.dlink.co.th Indonesia - www.dlink.co.id...
Page 73
DGS-3130 Series Layer 3 Stackable Managed Switch Hardware Installation Guide Egypt: Technical Support Call Center: +20 2258 66777 General Inquiries: info.eg@me.dlink.com Tech Support : support.eg@me.dlink.com Kingdom of Saudi Arabia: Technical Support: +966 1121 70009 General Inquiries: info.sa@me.dlink.com Tech Support: support.sa@me.dlink.com...
Page 74
Обновления программного обеспечения и документация доступны на Интернет-сайте D-Link. D-Link предоставляет бесплатную поддержку для клиентов в течение гарантийного срока. Клиенты могут обратиться в группу технической поддержки D-Link по телефону или через Интернет. Техническая поддержка компании D-Link работает в круглосуточном режиме ежедневно, кроме официальных праздничных дней. Звонок...
Page 75
Soporte Técnico de D-Link a través de Internet Horario de atención Soporte Técnico en www.dlinkla.com e-mail: soporte@dlinkla.com & consultas@dlinkla.com SUPORTE TÉCNICO Caso tenha dúvidas na instalação do produto, entre em contato com o Suporte Técnico D-Link. Acesse o site: www.dlink.com.br/suporte...
Page 76
香港電子郵件: service@cn.synnex-grp.com 香港、澳門維修據點查詢請參考http://www.dlink.com.hk/contact.html 網頁說明。 如果您是其他地區的用戶,請參考 D-Link 網站 www.dlink.com 查詢全球各地分公司的聯絡資訊以取得相關支援服務。 DUKUNGAN TEKNIS Update perangkat lunak dan dokumentasi pengguna dapat diperoleh pada situs web D-Link. Dukungan Teknis untuk pelanggan: Dukungan Teknis D-Link melalui telepon: Tel: 0800-14014-97 (Layanan Bebas Pulsa) Dukungan Teknis D-Link melalui Internet: Pertanyaan Umum: sales@id.dlink.com...