SELECTION OF A TRIGGER SOURCE ON THE VERT
MODE
A trigger signal is obtained in the following steps.
1) Set the SOURCE switch @ to INT.
2) Set the INT TRIG switch @ to VERT MODE.
3) Select the MODE switch
.
Table 1. Relation of trigger signal sources and switches
SOURCE
ENT
LINE
EXT
INT TRIG
CHI
CH2
VERT
MODE
V
CHI
CHI
CH2
CHI
CH2
CHI
CH2
CH2
Line
External
M
ALT
CHI
CH2
CH1,CH2
0
(ALT)
D
CHOP CHI
CH2
ADD
E
ADD
CHI
CH2
ADD
24
When the SOURCE switch to INT, INT TRIG switch to VERT
MODE, and MODE switch to ALT, the input signals applied to
CHI and CH2 become trigger source alternatively at each
sweep. Consequently, even for an observation of two wave
forms of different frequencies, the waveform of the each
channel is stably tiggered.
In this case, the signal should be applied to both CHI and CH2,
and the two signals have the same level portion in excess of the
rated amplitude each other. There should be a common por
tion of levels available that is above the rated amplitude of
CHI andCH2.
When a sinewave is applied to CHI, and a square wave is
applied to CH2, "A"s in Fig. 1 are the levels possible for
synchronization.
a) Input coupling: DC b) Input coupling: AC
CHI
1)
>
o
CH2
otfi-n n n
Fig. 1