5.5

Mounting / dismantling

The flush-mounted installation is made in a Ø 55 mm installation box according to DIN
49073 behind the push-button.
The device can be mounted in any position.
The adhesive label is to be removed and glued into the list (see system manual System
Access Point).
Wires not required are to be insulated.
The bus connection is established by means of the enclosed bus connection terminal.
The device is ready for operation after the bus voltage has been applied.
The description of the terminals is located on the housing.
Access to the device must be guaranteed for operation, testing, inspection, for maintenance
and repairs according to DIN VDE 0100-520.
5.6

Dismantling

Dismantling is carried out in the reverse order to mounting.