Section Iii Page - HP 2624 Manual

Display terminals
Table of Contents

Advertisement

Configuring the Terminal
To change the active values of the 8e 11, C 1 i c k,
FrameRlSte,
LocalEcho,
CapsLock,
ASCI 1881ts,
DeclmalType,
ImplledDecDlglts,
or
TrlSnsmlt
parameters, use an escape sequence of the following form:
8ELL" ON: <ESC>&k 1D
8ELL .. OFF: <ESC>&k OD
Click = ON: <ESC>&k 1Q
Click" OFF: <ESC>&k OQ
LocalEcho· OFF: <ESC>&k OL
LoclSlEcho = ON: <ESC>&k 1L
Caps Lock = OFF: <ESC)&k OC
Caps Lock" ON: <ESC)&k 1C
ASCII881h- NO: <ESC)&kOI
ASCII 88ih - YES: <ESC>&k 1 I
DecimalType..
US: <ESC>&k OX
EUR: <ESC) &k 1 X
ImpliedDecDigits" <x): <ESC>&k <x>Y
Transmit .. All Fields: <ESC)&k 02
Tran!lml t" Modified Fields: <ESC>&k 12
You may combine these and other <ESC>&k parameters
within one escape sequence. If you do, the final identifier
(such as C or I or L) must be uppercase and all preceding
identifiers must be lowercase. For example, to set
LocalEcho· ON and ASCI I 881 t!!"' YES you could use either
of the following escape sequences:
2·10
<ESC>&k 111 I
<ESC>&k 11 1 L
To change the active value of the Al ternate Set pa·
rameter, use an escape sequence of the following form:
(
Base Set:
<ESC»@
Set
A:
<ESC»A
Set B:
<ESC»B
Set C:
cESC»C
To change the active values of any of the remaining
parameters except FldSeparator, 81kTermnator, or
ESC) A 8 C, use an escape sequence of the following form:
Xmi tFnctnCA)" NO:
<ESC>&50A
Xmi tFnctnCA) • YES:
<ESC>&s 1 A
SPOW(8) •
NO:
<ESC>&! 08
SPOW(8) = YES:
<ESC>&!1 18
InhEoIWrpCC) .. NO:
<ESC>&s OC
InhEolWrpCC)" YES:
<ESC>&51C
Line/PlSge(D)" LINE:
<ESC>&s OD
Line/PageCD) = PAGE:
<ESC>&5 1 D
I nhHndShHG> • NO:
<ESC>&! OG
I nhHndShkCG) = YES:
<ESC>&51G
InhDC2(H)- NO:
<ESC>&! OH
InhDC2CH) = YES: <ESC>&s 1 H
AutoTermCJ) -
NO:
<ESC>&! OJ
AutoTermCJ) = YES:
<ESC>&s1J
ClearTermCK) •
NO:
<ESC>&! OK
ClearTermCK) = YES:
<ESC>&s 1 K
InhSlfTstCl) •
NO:
<ESC>&s OL
InhSlfTstCl) .. YES:
<ESC>&s 1 L
E5cXfer(N) = NO:
<ESC>&s ON
EscXferCN)· YES:
<ESC>&! 1 N
InhDcTstCW) -
NO:
<ESC>&s OW
InhDcTsHW)" YES:
<ESC>&!! 1W
You may combine these and other <ESC>&s parameters
within one escape sequence. If you do, the final identifier
(such as A or G or W) must be uppercase and all preceding
identifiers must be lowercase. For example, to set
Line/PlSgeCD)· PAGE, InhHndShkCG)- NO,and InhDC2CH)
=YES you could use any of the following escape sequences:
<ESC>&!1 1 dOg 1 H
<ESC>&5 Og 1 h 1 D
<ESC>&!I1h 1d OG
(
(

Advertisement

Table of Contents
loading

Table of Contents