en-us_main.book.book Page 17 Monday, September 11, 2023 4:50 PM
7
Attach the power cord ground wire to the
green ground screw.
8
Tighten all screws securely.
9
Reinstall the terminal block access cover.
b
e
d
a
White Wire moved from Ground Screw
b
Hot Leads of Power Cord (Black and Red)
c
Neutral Wire (White)
d
Power Cord Ground Wire
e
Ground Screw (green)
Four-Wire Direct Wire
• A UL-listed strain relief is
required.
• Use UL-listed 4-wire #10 AWG minimum
copper conductor cable. Allow at least 5 ft. (1.5
m) of wire to allow for removal and
reinstallation of the dryer.
1
Remove 5 inches (12.7 cm) of the outer
covering from the wire and remove 5 inches
of insulation from the ground wire. Cut off
approximately 1.5 inches (3.8 cm) from the
other three wires and strip 1 inch (2.5 cm)
insulation from each wire. Bend the ends of
the three shorter wires into a hook shape.
5'' (12.7 cm)
a
Ground Wire
c
b
a
1'' (2.5 cm)
a
2
Remove the terminal block access cover on
the upper back of the appliance.
3
Install UL-listed strain relief into the power
cord through-hole.
4
Thread the 4-wire #10 AWG minimum copper
power cable prepared in step 1 through the
strain relief.
a
Terminal Block
b
UL-Listed Strain Relief
c
UL-Listed 4-Wire Power Cord
5
Transfer the appliance's ground wire from
behind the green ground screw to the center
of the terminal block.
6
Attach the two hot leads (black and red) of the
power cord to the outer terminal block
screws.
7
Attach the neutral (white) wire to the center
screw of the terminal block.
8
Attach the power cord ground wire to the
green ground screw.
9
Tighten all screws securely.
10
Reinstall the terminal block access cover.