E83: Error reading the programme selector code
E83
Selector position code not envisaged by the configuration data or configuration error
Checks to perform:
Turn the appliance on, turn
the programme selector to
every setting: wait at least
10 seconds on each of the
settings before moving on to
the next one. Is alarm
E83 shown again?
YES
Check for any friction
between the control panel
and the knob.
Is it difficult to turn the
knob?
YES
Repair the coupling between
the control panel/selector
knob.
Repeat the diagnostic cycle
to check for any further
alarms.
E86
Checks to perform:
Replace the display board and run the diagnostic cycle to check for any further alarms.
E87
Checks to perform:
Replace the display board and run the diagnostic cycle to check for any further alarms.
2012 SOE/DT-mdm FCPD-dp
Guide to diagnostics of EWM09312 electronic controls
Repeat the diagnostic
cycle to check for any
NO
Replace the display board
and repeat the diagnostic
cycle to check for any
NO
E86: Programme selector configuration error
E87: Display board microprocessor faulty
!
Check that all the connectors are correctly inserted
further alarms.
further alarms.
!
!
Check that all the connectors are correctly inserted
!
!
Check that all the connectors are correctly inserted
!
57/69
If there are burns on the circuit board,
see page 67
If there are burns on the circuit board,
see page 67
If there are burns on the circuit board,
see page 67
599 75 18-74 Rev.00
E83
E86
E87