Deleting The Last Alarm - Electrolux EWM09312 Service Manual

Hide thumbs Also See for EWM09312:
Table of Contents

Advertisement

4.4 Deleting the last alarm

It is good practice to cancel the alarms stored:
after reading the alarm codes, to check whether the alarm re-occurs during the diagnostic cycle
after repairing the appliance, to check whether it re-occurs during testing
1. Enter the diagnostic mode,
2. Turn the programme selector clockwise to position eleven (alarm reading)
3. Simultaneously press the START/PAUSE sensor and the nearest sensor option
(as shown in the diagram).
4. Keep the buttons pressed until:
In the TC4 aesthetics: "E00" appears on the LCD screen (at least 5 seconds).
In the TC5 aesthetics: the LEDs stop flashing (at least 5 seconds).
2012 SOE/DT-mdm FCPD-dp
Guide to diagnostics of EWM09312 electronic controls
TC 4
14/69
TC 5
599 75 18-74 Rev.00