Select the Screen Connection tab.
Select/enter the value for "Screen Type", "Receiving Card Size", "Columns" and "Rows", and use "Ethernet Port
No." and the screen configuration section to configure the connection.
* For details of the configuration procedure, refer to the User's Manual.
Notes on the setting operation:
Perform these setting procedures prior to the redundancy settings configuration.
Make sure that the value of "Quantity of Screens" is 1.
(To change a different value to 1, click the Configur" button.)
It is not necessary to configure the settings for Sending Card 2.
When the settings configuration is complete, click the "Send to HW" button.
Select the Sending Card tab and click "Add".
The Redundancy Settings screen is displayed.
E (End)
S (Start)