Yamaha EC-03 2012 Owner's Manual page 44

Table of Contents

Advertisement

CHARGING THE BATTERY
1
2
3
Battery depletion
4
The electric output capacity of the
Li-ion battery used in the EC-03 gradu-
5
ally decreases in the course of use. Al-
though the extent of depletion varies
6
based on the conditions of use, electric
output capacity typically decreases to
70% of a new battery when having trav-
7
eled 8000–10000 km for two years.
This is equivalent to charging about
8
500 times with the condition of riding
16–20 km on a single charge.
9
Battery electric output auto-stop-
ping function
The battery is equipped with a function
to prevent further use in case of exces-
sive depletion. When eight years have
passed since initial battery charging or
the accumulated charging amount has
reached 14000 Ah, the battery will no
longer be usable.
TIP
When the battery is replaced with
a new one, fully charge the battery
once before using it. If the battery
is not fully charged, the battery lev-
el indicator does not show the pre-
cise battery level.
At low temperatures such as 0 C,
the electric output capacity de-
creases by approximately 20%
compared with normal tempera-
ture.
If a depleted battery is used at low
temperatures, the electric output
capacity decreases by approxi-
mately 20% compared with normal
temperatures.
6-10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ed06 2012

Table of Contents