Upper Communication Unit for Digital Sensor
SC-GU1-485
Thank you very much for purchasing Panasonic products. Read this
Instruction Manual carefully and thoroughly for the correct and optimum
use of this product. Kindly keep this manual in a convenient place for quick
reference.
When this product is used for a safety device, construct the
system such that the device itself always operates in the safety
side.
WARNING
For details of the communication command etc. of the upper communication unit for digital sensor
SC-GU1-485, refer to 'Product specification' and 'Communication command specification'.
1
SYSTEM CONFIGURATION
This product enables to connect max. 16 units of applicable amplifier
between the main unit (SC-GU1-485) and the end unit (SC-GU1-EU), and
connect max. 31 nodes.
The main unit can read out / write in the setting contents of the connected
applicable amplifier.
This product enables to output the all output signals of the connected
applicable amplifier to PLC (Programmable Logic Controller) etc. collectively.
Sensor amplifer (Optional)
(Max. 16 units can be connected)
To PLC
Main unit
SC-GU1-485
Link cable
To power supply
SC-GU1-CC02 (Accessory)
Quick-connection cable
CN-73-C2 (Accessory)
End plate
MS-DIN-E (Optional)
Note: This is used to control the output signal via signal transmission.
2
SPECIFICATIONS
Type
Item
Model No.
Applicable amplifier
Connectable units
Max. 16 units of sensor amplifer per SC-GU1-485
Connectable nodes
Supply voltage
Current consumption
45mA or less (10mA or less for SC-GU1-EU)
Communication method
Synchronization method
Electrical characteristic
Communication cable: Within100m SC-GU1-485 (termination) to PLC
Total extension length
Power supply cable: Less than10m
-10 to 55
(If 4 to 7 amplifiers are connected in cascade: -10 to 50 ,
Ambient temperature
if 8 to 16 amplifiers are connected in cascade: -10 to 45
(No condensation or icing allowed), Storage: -20 to 70
Ambient humidity
Material
Weight
SC-GU1-EU (End unit): 1 pc.
CN-73-C2 [Quick-connection cable (cable length 2m)]: 1 pc.
Accessories
SC-GU1-CC02 [Link cable (cable length 0.2m)]: 1 pc.
INSTRUCTION MANUAL
MJE-SCGU1485 No.0090-60V
End unit SC-GU1-EU (Accessory)
End plate
MS-DIN-E (Optional)
Wire-saving connector
CN-701(Optional) (Note)
To next node
Max.31 nodes can
be connected
Quick-connection cable
CN-71-C
CN-72-C (Optional)
Main unit
SC-GU1-485
Refer to 'Product specification'.
Max. 31 nodes
24V DC 10% Ripple P-P10% or less
2 wire half duplex method
Asynchronous communication method
Conforming to EIA RS-485
35 to 85% RH, Storage: 35 to 85% RH
Main body enclosure: Heat-resistant ABS
35g approx. (10g approx. for SC-GU1-EU)
3
MOUNTING AND CONNECTION
How to mount
Fit the rear part of the mounting section of the unit
on a 35mm width DIN rail.
Press down the rear part of the mounting section of
the unit on the 35mm width DIN rail and fit the front
part of the mounting section to the DIN rail.
How to remove
Push the amplifier forward.
Lift up the front part of the amplifier to remove it.
Note:
Take care that if the front part is lifted without pushing the
amplifier forward, the hook on the rear portion of the mounting section is likely to break.
How to connect
Be sure that the power supply is off while adding or removing the units and
mounting or removing the link cable (SC-GU1-CC02), the quick-connection
cable and the wire-saving connector (CN-701).
When the amplifiers are mounted in cascade, mount the optional end plates (MS-DIN-E)
at the both ends of the amplifiers to hold them between the flat sides of the plates.
Up to maximum 16 sensor amplifers can be connected in cascade between
the main unit (SC-GU1-485) and the end unit SC-GU1-EU).
In case two different models of sensor amplifer are mounted in cascade, be
sure to mount identical models together.
Max. 31 nodes connection is possible with this communication unit.
For the cautions of the sensor amplifers, refer to the instruction manual
enclosed with the amplifiers.
Mount the main unit, the end unit and
the sensor amplifer, one by one, on
the 35mm DIN rail and set them
close to each other.
Insert the main unit side connector of
the link cable (accessory) to
side of the main unit, and insert the
quick-connection cable (accessory) to
the
side of the main unit.
When inserting them, be sure to hold
the connector part.
Fit the cover to the main unit side
connector of the link cable (accessory).
Insert the quick-connection cable
(optional) or the wire-saving connec-
tor (optional) to the connector of the
sensor amplifer.
When inserting them, be sure to hold
the connector part.
Insert the end unit side connector of
the link cable to the connector of the
end unit.
When inserting them, be sure to hold
the connector part.
Mount the end plates (optional) at
both ends to hold the amplifiers
between their flat sides.
Tighten the screws to fix the end
plates.
How to dismantle
Pressing the projection at the top of
each connector, pull out the connector.
Remove the main unit, the end unit
and the sensor amplifers.
Note: Take care that if the connector is pulled out without pressing the projection, the projection may
break. Do not use a link cable, quick-connection cable or wire-saving connector whose
projection has broken.
Furthermore, do not pull by holding the cable, as this can cause a cable-break.
4
CONNECTION DIAGRAM
Main unit
(SC-GU1-485)
Color code of
lead wire
(Brown)
V
(Black) Open (Note)
(Blue) 0V
Note: Be sure to insulate it.
35mm width DIN rail
End unit
(Accessory)
Sensor amplifier
(Optional)
the
Main unit
Main unit con-
Main unit con-
nector part
nector part
Quick-connection
cable (Accessory)
Main unit side
connector
of
the link cable
(Accessory)
End
unit
connector of the link
cable (Accessory)
Quick-connection
cable
wire-saving connector (Optional)
End plate
(Optional)
End plate (Optional)
End unit
(SC-GU1-EU) (Accessory)
Link cable
(SC-GU1-CC02) (Accessory)
Quick-connection cable
(CN-73-C2) (Accessory)
Cover
side
or

Advertisement

loading

Summary of Contents for Panasonic SC-GU1-485

  • Page 1 This product enables to connect max. 16 units of applicable amplifier Up to maximum 16 sensor amplifers can be connected in cascade between between the main unit (SC-GU1-485) and the end unit (SC-GU1-EU), and the main unit (SC-GU1-485) and the end unit SC-GU1-EU).
  • Page 2 The communication distance should be within the specification. To upper controller CAUTIONS When the main units (SC-GU1-485) are connect- ed to each other, max. 31 nodes can be connect- This product has been developed / produced for industrial use only.