Key Snapshots; Key Snapshot Operations (Flexi Pad Control Block) - Sony MKS-X1115 User Manual

Live production processor system
Table of Contents

Advertisement

1
Open the Home > M/E-1 > Key1 > Resizer/Proc Key
> Enhanced Effect menu (11101.42).
2
Set the [Resizer] button to the on state.
3
Set the [Dual Rszr Effect] button to the on state.
4
Set the [Mask] button to the on state.
5
In the [Mask Source] group, select a mask source.
Box: Box
Circle: Circle
Set the following parameters.
No.
Parameter
1
H
2
V
3
Size
4
Soft
5
Aspect
To rotate a mask pattern
In the [Rotation] group, select a rotation type.
Angle: Incline a pattern at a fixed angle.
Speed: Rotate a pattern at a fixed speed.
When the [Angle] button is selected, set the following
parameter.
No.
Parameter
Adjustment
1
Angle
Inclination angle of pattern
• A value of –1.00 corresponds to
• A value of +1.00 corresponds to
• A value of 0.00 corresponds to
When the [Speed] button is selected, set the following
parameter.
No.
Parameter
Adjustment
1
Speed
Rotation speed of pattern
• A value of –100.00 corresponds
• A value of +100.00
• A value of 0.00 corresponds to
To invert a mask area
Set the [Mask Invert] button to the on state.
Adjustment
Horizontal position
Vertical position
Size
Softness
Aspect ratio
a rotation of one turn
counterclockwise.
a rotation of one turn clockwise.
no rotation.
to 4 revolutions/second
counterclockwise rotation.
corresponds to 4 revolutions/
second clockwise rotation.
no rotation (stationary).

Key Snapshots

You can save key settings (excluding key inserted/
removed (on/off) status and key priority) in a register and
recall the settings when required. Settings information of
cross-points, key modifiers, and independent key
transitions can be selected and recalled. There are four
key snapshot registers for each key.
For details about editing a key snapshot register, see
"Key Snapshot Register Operations" (page 292).
Saving and recalling a key snapshot can be performed
using the Flexi Pad control block, key fader control block,
or the menu.
Key Snapshot Operations (Flexi Pad
Control Block)
You can configure a key snapshot using the Flexi Pad
control block of the target switcher bank.
This section describes setting a key snapshot on key 1 as
an example.
Memory recall section in key snapshot
operation mode
Pressing the [KEY] button in the Flexi Pad control block
switches the memory recall section to key operation
mode.
You can select key snapshot registers (1 to 4) using the
buttons in the memory recall section.
The register name is displayed on buttons for registers
with a registered snapshot.
The register number is displayed on buttons for registers
without a registered snapshot.
The button color varies as follows, according to the
register state.
Gray characters: Register not containing a registered
snapshot
White characters: Register containing a registered
snapshot
Lit orange: Last recalled register
Saving a key snapshot
Set a key and save a key snapshot register using the
following procedure.
1
Press the [KEY] button.
The memory recall section switches to key operation
mode.