JVC CL-S500 Series Installation Manual
JVC CL-S500 Series Installation Manual

JVC CL-S500 Series Installation Manual

21.3-inch (54 cm) color lcd monitor
Hide thumbs Also See for CL-S500 Series:

Advertisement

Quick Links

21.3-inch (54 cm) Color LCD Monitor
Installation Manual
for system administrators
Model: CL-S500BG0UA
CL-S500BG0EA
CL-S500BG2UA
CL-S500BG2EA
Important
Please read this "Installation Manual" carefully before use.
Please make sure to read the "Safety precautions" in the "Operation Manual" first and
keep this "Installation Manual" in a safe and easily accessible place for future reference.
B5E-0205-30

Advertisement

Table of Contents
loading

Summary of Contents for JVC CL-S500 Series

  • Page 1 21.3-inch (54 cm) Color LCD Monitor Installation Manual for system administrators Model: CL-S500BG0UA CL-S500BG0EA CL-S500BG2UA CL-S500BG2EA Important Please read this “Installation Manual” carefully before use. Please make sure to read the “Safety precautions” in the “Operation Manual” first and keep this “Installation Manual” in a safe and easily accessible place for future reference. B5E-0205-30...
  • Page 2: Table Of Contents

    Contents Product security ..................3 Package contents ................... 4 Connecting the cables ................. 5 Switching screen orientation ............. 7 Adjusting the screen angle ..............9 Monitor information ................9 1. Operation button guide ............. 9 2. Information ..................10 3. Current state .................11 4.
  • Page 3: Product Security

    Product security This product is operated by the dedicated microcomputer system. To delete or alter the program could lead to abnormal display. When connecting this monitor to a workstation to change the settings or adjust the accuracy control, do not disconnect the USB cable while the devices are communicating.
  • Page 4: Package Contents

    Package contents Please check if the following items are included in this product package. If any item is missing, contact your dealer for replacement. Do not use the supplied power cord for anything other than this monitor. Note □ Monitor □...
  • Page 5: Connecting The Cables

    Connecting the cables Turn off the workstation. DisplayPort connection : Connect the supplied DisplayPort cable between the monitor’s DisplayPort IN and the workstation’s DisplayPort connector. DVI-D connection : Connect a Dual Link DVI cable between the monitor’s DVI-D and the workstation’s DVI output connector.
  • Page 6 How to setup multiple monitors in daisy-chain Please connect multiple monitors together using DisplayPort as below. For details on the monitors and graphics cards supporting daisy-chain, please see our website. To the DisplayPort output of the workstation DisplayPort cable DisplayPort cable DisplayPort cable - 6 -...
  • Page 7: Switching Screen Orientation

    Switching screen orientation CL-S500 can be used in both landscape and portrait orientation by changing the resolution setting in Monitor Properties. Follow the instructions below on how to switch screen orientation. To use the monitor in portrait orientation, a graphics card that supports vertical Note timing is required.
  • Page 8: Adjusting The Screen Angle

    Adjusting the screen angle The screen of this monitor can be adjusted to any angle within the range shown below. Hold the screen with both hands and adjust the angle slowly. 20 degrees 45 degrees 45 degrees 5 degrees Caution Be careful when adjusting the screen angle.
  • Page 9: Monitor Information

    Monitor information You can display various monitor information on the screen (On Screen Display: OSD) for adjustment. 1. Operation button guide “Operation Button Guide” is not displayed on the screen in the default setting. When pressing any one of operation buttons (A–C), “Operation Button Guide ① ” appears. When no operation is done, it will disappear after 10 seconds.
  • Page 10: Information

    2. Information 1) Display the “Operation Button Guide ①” by pressing any one of operation buttons (A–C). 2) Press the “MENU” button. 3) Select “INFORMATION” from MENU 1/2 using the “▼” or “▲” button and press the “OK” button. The following “INFORMATION 1/2” OSD appears as below. The OSD page switches between “INFORMATION 1/2”...
  • Page 11: Current State

    3. Current state 1) Display the “Operation Button Guide ①” by pressing any one of operation buttons (A–C). 2) Press the “MENU” button. 3) Select “CURRENT STATE” from MENU 1/2 using the “▼” or “▲” button and press the “OK” button. The following “CURRENT STATE” OSD appears as below. Current luminance CURRENT STATE Current ambient Light...
  • Page 12: Osd Menu Hierarchy

    5. OSD menu hierarchy The OSD structure and a brief explanation for each menu item as follows. MENU - INFORMATION ..........Shows monitor information - CURRENT STATE ..........Shows monitor current state - DICOM CONFORMANCE TEST ....DICOM conformance test -...
  • Page 13 - USB POWER - Auto * ............ON only when USB UP is connected - Off ............... OFF - READING LIGHT - Low .............. Low illuminance - Middle ............Medium illuminance - High ............High illuminance - Auto ............Automatic adjustment -...
  • Page 14: Performing The Dicom Conformance Test

    Performing the DICOM conformance test Note This function is available only when the monitor has been calibrated to DICOM GSDF. Performing the DICOM conformance test ensures DICOM conformance of the monitor by measuring and checking the monitor properties. The DICOM conformance test is recommended to be performed after 60 minutes of continuous lighting time of the backlight of the LCD panel.
  • Page 15 6) Select “DICOM CONFORMANCE TEST” from MENU 1/2 using the “▼” or “▲” button and press the “OK” button. Then select “Yes” for “START TESTING” from “DICOM CONFORMANCE TEST” OSD and press the “OK” button. If “DICOM GSDF” is NOT selected, the message “START TESTING” will not Note appear.
  • Page 16: Setting The Configuration Data

    Setting the configuration data CL-S500 can save up to three settings of luminance-Gamma-color as configuration data within the monitor and they can be switched by selecting a configuration number appeared on the current operating state OSD screen. The following three configuration settings are saved prior to shipping as factory default.
  • Page 17 CURRENT STATE 5 M P C U R R E N T S T A T E L U M I N A N C E 4 0 9 A M B L I G H T 1 0 0 . 0 lx C O L O R 7 5 0 0 K ( x = 0 .
  • Page 18: Dynamic Gamma

    Dynamic gamma CL-S500 comes with our original function, dynamic gamma adjustment. By enabling this function, the images on the screen are automatically identified to distinguish between monochrome and color, and the respective images are displayed with the most suitable grayscale. The default is “Disable”, but by using OSD operation can change it to “Enable”.
  • Page 19 INFORMATION 1/2 5 M P I N F O R M A T I O N 1 / 2 M O D E L C L - S 5 0 0 S E R I A L * * * * * * * * * * * * V S P U R e v .
  • Page 20: Switching Input Source

    Switching input source Please operate input source change following the procedure mentioned below. Setting method 1 You can change input source by OSD. 1) Display the “Operation Button Guide ① ” by pressing any one of operation buttons (A–C) . 2) Press the “MENU”...
  • Page 21: Auto Text Mode

    Auto text mode CL-S500 comes with the function called “AUTO TEXT MODE”, which automatically detects a text window (white window) used for showing information such as report and patient list, and reduces its luminance depending on the size of the display area of the window.
  • Page 22 Setting method 2 You can assign the AUTO TEXT MODE function to the function buttons (F1 or F2) which allows you to enable or disable the function easily via button operation. The following explains how to assign to the “F2” button. 1) Display the “Operation Button Guide ①...
  • Page 23: Human Presence Sensor

    Human presence sensor Human presence sensor is mounted on this product, and it can detect human motion. When leaving your seat, “Stand-by” mode is automatically activated. It helps to reduce power consumption. The default is “Disable”, but OSD operation can change it to “Enable”.
  • Page 24: Locking The Image Display Orientation

    Locking the image display orientation CL-S500 can be used both Portrait and Landscape orientation rotating the panel. If the user would like to use with proper screen even if changes the panel orientation, need to change EDID data which is operated in the OSD (EDID). It is set to “Auto Selection” as default.
  • Page 25: How To Display The Test Pattern

    How to display the test pattern To display the Test pattern to check the image quality prior to the use of the monitor, press the button located in the front of the monitor as follows. Select test pattern 1) Display the “Operation Button Guide ① ” by pressing any one of operation buttons (A–C) .
  • Page 26 Display method 1) Display the “Operation Button Guide ① ” by pressing any one of operation buttons (A–C) . 2) Display a test pattern by pressing the “F1” button. The test pattern disappears automatically in 10 seconds. You can also turn it off by pressing the “F1” button again while the test pattern is activated.
  • Page 27: Displayport Setting

    DisplayPort setting You can reduce power consumption by selecting “Disable” for DISPLAYPORT on MENU 2/2 when using only DVI (DisplayPort is not used at all). With this setup, DisplayPort OUT connector does not work. Setting method 1) Display the “Operation Button Guide ① ” by pressing any one of operation buttons (A–C) .
  • Page 28: Usb Hub

    USB hub CL-S500 has a USB 2.0 compliant hub. Peripheral USB devices can be connected to this monitor directly by connecting the supplied USB cable to a workstation supporting USB or other USB hubs. The default is “Auto”, but OSD operation can change it to “Off”. Setting method USB POWER can turn on and off by OSD.
  • Page 29 The supplied USB cable can also be used for the followings: • To calibrate the monitor (An optional calibration kit is required.) • To calibrate multiple monitors in succession ● To calibrate the monitor Connect the supplied USB cable between one of the monitor’s UP’s and the workstation’s USB down port.
  • Page 30: Reading Light

    Reading light This product is equipped with reading light for hand lighting. You can reduce the burden on your eyes in a dim room by illuminating documents or your keyboard in the environment (20 Lux or less), such as a reading room, where mammography diagnosis is performed.
  • Page 31: Restore Factory Preset

    Restore factory preset Please follow the steps as below when restoring your monitor to “Factory Preset”. Restore method 1) Display the “Operation Button Guide ① ” by pressing any one of operation buttons (A–C) 2) Press the “MENU” button. 3) Select “FACTORY PRESET” from MENU 2/2 using the “▼” or “▲” button and long press the “OK”...
  • Page 32: Locking The Stand-By Button

    Locking the stand-by button CL-S500 has the function to lock the Stand-by button. You can make the Stand-by button unavailable in front of the monitor to avoid turning off the monitor accidentally. Stand-by button How to lock Long press the Stand-by (Power) button for more than four seconds without any OSD on the screen.
  • Page 33: Operation Button Lock

    Operation button lock CL-S500 has the function to lock operation buttons . You can make the operation buttons unavailable in front of the monitor to avoid changing your setting accidentally. Operation button (4 pieces) How to lock Long press the “▼” and “▲” button for more than four seconds without any OSD on the screen.
  • Page 34: Attaching An Arm Stand

    Attaching an arm stand The tilt stand is interchangeable with commercially available arms. After checking the specifications of the arm to be used, pay attention to the following points when selecting. • Come with a mount plate with 4 slotted screw holes at 100 mm ×...
  • Page 35: Anti-Theft Security Slot

    Anti-Theft security slot This monitor has a built-in Kensington MicroSaver* Security Slot by ACCO Brands Corporation. Please purchase the MicroSaver lock at PC stores separately. * Kensington, MicroSaver are registered trademarks of ACCO Brands Corporation. - 35 -...
  • Page 36: How To Change The Fuse

    How to change the fuse Note for AC INLET with fuse AC Inlet has a built-in fuse. When replacing the fuse, be sure to use only a correctly rated approved type, re-fit the fuse cover. How to replace the fuse Open the fuse compartment with the blade screwdriver, and replace the fuse.
  • Page 37: Troubleshooting

    Troubleshooting If you suspect a problem, please check the following items before requesting repair. Symptom The monitor does not turn • Make sure the monitor is plugged ( P5 ). • Check if the POWER switch is turned on. (The LED indicator is off.) •...
  • Page 38 This page is intentionally left blank. - 38 -...
  • Page 39 CL-S500 Installation Manual November 2023 Edition PZZ11-2646C Notes for the Installation Manual • No part of this manual, whether partly or wholly, may be reproduced or copied without authorization. • The content of this manual is subject to change without notice. •...
  • Page 40 3-12, Moriya-cho, Kanagawa-ku, Yokohama-shi, Kanagawa 221-0022, JAPAN Printed in Japan © 2019 JVCKENWOOD Corporation B5E-0205-30 231107...

This manual is also suitable for:

Cl-s500bg0uaCl-s500bg0eaCl-s500bg2uaCl-s500bg2ea

Table of Contents