D-Link DFE-2600 User Manual page 112

Dfe-2600 series ethernet/fast ethernet dual-speed managed/unmanaged stackable hubs
Hide thumbs Also See for DFE-2600:
Table of Contents

Advertisement

Dual-Speed Stackable Hub Web-based Management User's Guide
Interval (1..3600)
pled for each bucket. This interval can be set to any number of seconds
between 1 and 3600 (1 hour).
Other functions in the History Control Table are:
Delete
Click the Delete button to remove an entry.
View
To view statistics on an entry, click the View button. Sta-
tistics are organized in a table (shown below).
History Table
The History Table (shown below) is an historical sampling of Ethernet sta-
tistics on a particular Ethernet interface. The History Control Group sets
parameters for the History Statistics Group for a regular collection of these
samples. These samples are collected in historical data entries, called buck-
ets, each poll interval.
The different statistics are described below:
Time Stamp Shows when the sample was taken.
Drop Events
dropped by the probe due to lack of resources during this sampling inter-
100
The interval in seconds over which the data is sam-
The total number of events in which packets were
Web-based Network Management