Important safety information

NOTE: The extension bars that ship with this kit are only
for use with Compaq/HP models EO4500, EO4501,
EO4502, EO4503, EO4504, EO4505, EO4506,
HSTNR-P011, and HSTNR-P012 Power Distribution
Control Units and HP Uninterruptible Power Supplies
(UPS).
WARNING: To reduce the risk of personal injury from
electric shock, do not remove the cover. There are no field-
serviceable or user-serviceable components inside.
WARNING: A risk of personal injury from electric shock
and hazardous energy levels exists. The installation of
options and routine maintenance and service of this
product must be performed by individuals who are
knowledgeable about the procedures, precautions, and
hazards associated with AC power products.
Follow these safety precautions when connecting multiple hardware
components to power sources.
WARNING: To reduce the risk of personal injury or
damage to the equipment:
Plug the input power cord into a grounded (earthed)
electrical outlet that is located near the equipment and
is easily accessible.
Be sure that the load products connected to the mPDU
are adjusted for, or otherwise capable of operation
from the same line voltage supplying the mPDU. Failure
to verify the voltage can lead to severe equipment
damage.
Do not overload the mPDU. The total input current
rating of all equipment connected to each output
cannot exceed the total output rating marked on the
mPDU.
WARNING: To reduce the risk of personal injury from
high-leakage current, verify earth connection before
connecting the power supply.
The summation of input power for multiple pieces of
information technology equipment through the use of
power products can result in high-leakage currents.
If the total system leakage current for a system of
components exceeds 3.5 mA:
The use of a detachable input power cord is
prohibited.
The input power cord must be securely attached, and it
should be connected to the AC mains by hardwiring or
through the use of a non-residential, industrial-style
plug that maintains positive earth connection.
If the total system leakage current through the ground
conductor exceeds 5% of the input current per line
under normal operating conditions, the system loads
should be divided among multiple power connections.

Regulatory compliance information

All regulatory certifications for these products were obtained under
the following agency series numbers:
Control unit
Series number
228481-001
EO4500
228481-002
EO4501
228481-003
EO4502
228481-004
EO4503
228481-006
EO4504
228481-007
EO4505
228481-008
E04506
435530-001
HSTNR-P011
435530-003
HSTNR-P012
458745-001
HSTNR-P016N
481337-001
HSTNR-P017
484168-001
HSTNR-P016-A
Extension bar
Series number
411273-001
HSTNR-PS02
411273-002
HSTNR-PS03
228480-003
EO4602

Kit contents

Control unit hardware (if included)
The following hardware pieces are included:
Control unit with extension bars
o
0U mounting brackets (2)
o
1U mounting brackets (2)