Procedure for Restoring Previous Version

Required Media and Data

Make sure that you have the installation CD, patch installer and backed-up data for the
previous version.
Delete Canon Network Video Recorder VK Series v2.0 from Add or Remove
1
Programs in Control Panel.
Delete the following folders.
2
Configuration file path for OS other than Windows Vista
<Startup drive for OS>: \Documents and Settings\All Users\Application Data\
<All drives> :\WebView-NVR
Configuration file path for Windows Vista
<Startup drive for OS>:\ProgramData\Canon\WebView\NVR\
<All drives>:\WebView-NVR"
Install the previous version by using the installation CD and patch installer for the
3
previous version.
Stop the Storage Server in the Storage Server configuration.
4
Quit the Viewer.
Replace the existing folders with the following backed-up data.
5
In case of Version 1.1, 1.2, 1.3 and 1.4
Configuration file path for OS other than Windows Vista
<Startup drive for OS>:
Configuration file path for Windows Vista
<Startup drive for OS>:
In case of Version 1.0
<Installation folder for VK-64/VK-16> \NVR\1.0\conf
Start up the Storage Server.
6
248
Canon\Webview\NVR
\Documents and Settings\All Users\Application
Data\Canon\Webview\NVR
\ProgramData\Canon\WebView\NVR\
<<Example>> C:\Program Files\Canon\WebView\NVR\1.0\conf