Table 8 Fabric OS 6.2.1 closed defects (continued)
Closed defect summary
HP StorageWorks DC SAN Director temperature sensor reported spurious
readings leading to the CRITICAL HIL-1502 message without having
first issued the HIL-1501 warning.
After a power cycle, HIL-1610 WARNING appeared on the HP
StorageWorks 8/40 SAN Switch, reporting that Fan/PS unit 1 was not
supplying power; fan speeds were not available.
HP StorageWorks Encryption SAN Switch can go to the faulty state after
upgrading to any Fabric OS 6.2.0x version.
Firmwarecommit can fail on the HP StorageWorks Encryption SAN Switch
or encryption blade with a message about a missing properties file when
upgrading to Fabric OS 6.2.0d or later.
An internal timing race condition can cause one or more F_Ports or E_Ports
to be brought down, leading to frame discards. The port will be brought
back online automatically at the end of the HA or firmware upgrade
operation.
In a FICON environment, some frame drops occur on TI zone-enabled ISLs
during an upgrade to or from Fabric OS 6.2.0x. This causes Interface
Control Checks (IFCCs) to be reported.
Fabric OS 6.2.1a fixes
Table 9 (page 37)
Table 9 Fabric OS 6.2.1a closed defects
Closed defect summary
Device connectivity across the FCIP link with the HP StorageWorks 400 MP
Router or MP Router blade will be lost after WAN issues. Credit information
from the portshow of the FCIP tunnel will display a negative credit number.
SMI failed to discover all switches over EX_Port after hafailover, and
reports LOGIN FAILED after the GPL2 query targeted to the translate
domain is rejected.
SFP power supply values are not displayed correctly after doing a
nondisruptive firmware upgrade to Fabric OS 6.2.1.
High CPU load from DCFM doing supportsave causes the port to go
offline with a laser FLT/link reset.
Name server database counts do not match for Fabric OS 6.2.1 and M-EOS
9.9.0 switches in the same fabric, so the host cannot see the device. This
occurs when an HBA capable of an RHBA command and an M-EOS switch
are in the same fabric.
The host cannot see the device due to a login failure with a non-FC standard
value (0x0000EF) to the name server, when the switch has port alpa also
enabled in interopmode 2.
With Fabric OS 6.2.1 in a logical switch setup, a segmentation fault/core
dump occurs after configdefault.
lists defects closed in the Fabric OS 6.2.1a firmware release.
Solution
Fixed in Fabric OS 6.2.1
Workaround prior to update: Ignore
isolated/spurious high temperature
CRITICAL errors when not preceded by
warnings.
Fixed in Fabric OS 6.2.1
Workaround prior to update: This warning
can be safely ignored when seen at boot
time. It is caused by a single false sensor
reading below minimum.
Fixed in Fabric OS 6.2.1
Fixed in Fabric OS 6.2.1
Fixed in Fabric OS 6.2.1
Fixed in Fabric OS 6.2.1
Solution
Fixed in Fabric OS 6.2.1a
Fixed in Fabric OS 6.2.1a
Fixed in Fabric OS 6.2.1a
Workaround prior to update: Executing
the same command again shows the
correct values.
Fixed in Fabric OS 6.2.1a
Fixed in Fabric OS 6.2.1a
Fixed in Fabric OS 6.2.1a
Fixed in Fabric OS 6.2.1a
Fabric OS 6.2.1a fixes