Troubleshooting
If you experience any of the following issues while using the gigabeat, check the following
guide for the possible cause before requesting service.
Issue
The gigabeat
doesn't power up.
The button doesn't
work.
The battery is
consumed quickly
after charge.
Playback cannot be
performed.
There is no sound.
The charge indicator
doesn't illuminate, in
charging operation.
The charge indicator
turned off while the
AC adapter was
connected.
The PC does not
recognize the
gigabeat.
I Resetting
If the issue cannot be resolved after taking the above corrective actions, reset the main
unit by following the steps below:
1 Unplug the AC adapter from the main unit.
2 Set the BATTERY switch to OFF and then set it to ON again after approximately five
seconds. The play mode and other conditions will return to their initial settings.
68
gigabeat F60_OP62_70(E)â¸î
Cause
The BATTERY switch
Set the BATTERY switch to
is set to OFF.
ON.
There is insufficient
Connect the AC adapter and
power remaining in the
charge the built-in battery.
built-in battery.
The gigabeat is in
Reset the HOLD switch to
HOLD mode.
cancel the HOLD mode.
The button is not
When turning on the power,
being pressed long
press the POWER button for
enough.
two seconds or longer.
The gigabeat is
The gigabeat cannot be
connected to a PC.
operated while being con-
nected to a PC.
The built-in battery
Replace with a new battery. To
has failed.
replace the built-in battery,
contact TOSHIBA Customer
Service by calling.
(Phone # on "Stop SHEET")
There is no track.
Use gigabeat room to transfer
tracks.
Check the connection between
The EARBUDS are
the EARBUDS and wired
not connected
remote control and main unit.
properly.
The volume is set to
Adjust the volume.
the minimum.
The BATTERY switch
Set the BATTERY switch to
is set to OFF.
ON.
The gigabeat is not
Check the connection between
connected properly.
the AC adapter/AC cable and
the main unit.
Outside the specified
Charge within the operating-
operating-temperature
temperature range.
range.
The charge is
This is a safety feature. Keep
automatically stopped
the gigabeat in the charging
to limit the tempera-
operation. Charging will
ture increase in the
resume after a while.
gigabeat.
The gigabeat is not
Check the connection with the
properly connected to
PC.
the PC.