Led Behavior - Dell PowerConnect M8428-k Manual

Dell 10 gb ethernet pass through-k  for m1000e software user’s manual (for system administrators)
Hide thumbs Also See for PowerConnect M8428-k:
Table of Contents

Advertisement

• Downlink (server blade) does not support the link protocol of the port group to which it is
attached
• Uplink (remote peer) does not support the link protocol of the port group to which it is attached
The following drawing demonstrates link protocol mismatch conditions:
Blade Configuration:
KR
KX4
KX
KR
KX4
KX
KX4
KX4
KR
KX4
KX
KR
KX4
KX
KX4
KX4
1.4

LED Behavior

The LED behavior is described in the following table:
Table 3 - LED Behavior
Condition
Link down
Figure 2: Link Protocol Mismatch Examples
Module Configuration:
SFP+ SR
SFP+ SR
SFP+ SR
SFP+ LR
SFP+ LR
SFP+ LR
No Cable
EMPTY
Passive Cable
Passive Cable
Passive Cable
SFP
SFP
SFP
SFP+ LRM
SFP+ LR, No Link
Green LED
Amber LED
off
off
Description
This condition occurs in the following cases:
Server blade not present, powered down, or link is
inactive
Uplink port module not present
Uplink port cable not connected
One or both of the internal and/or external links is
down
Rev 1.00
Link up
Blade is not KR
Blade is not KR
Link up
Blade is not KR
Blade is not KR
No cable detected
Module not present
Link up
Blade is not KR
Blade is not KR
Module is SFP (1GbE)
Module is SFP (1GbE)
Module is SFP (1GbE)
LRM module not supported
No link with remote side
7

Advertisement

Table of Contents
loading

Table of Contents