Resolving A Link Protocol Mismatch; Resolving Cli Connectivity Problems; Recovery From Non-Responsive 10Gbe Ptm Cli; Recovery From A Software Update Failure - Dell PowerConnect M8428-k Manual

Dell 10 gb ethernet pass through-k  for m1000e software user’s manual (for system administrators)
Hide thumbs Also See for PowerConnect M8428-k:
Table of Contents

Advertisement

chassisaction –m switch-<n> powercycle
where <n> is the switch number [1-6].
5.3

Resolving a Link Protocol Mismatch

Log in to 10GbE PTM CLI and run the "show port link" command. Check the status of the down-
link and uplink in the relevant port to identify the mismatch – see
5.4

Resolving CLI Connectivity Problems

Reboot the 10GbE PTM through the CMC CLI using the following command:
chassisaction –m switch-<n> powercycle
where <n> is the switch number [1-6].
5.5

Recovery From Non-Responsive 10GbE PTM CLI

Reboot the 10GbE PTM through the CMC CLI using the following command:
chassisaction –m switch-<n> powercycle
where <n> is the switch number [1-6].
5.6

Recovery From a Software Update Failure

1. Reboot the 10GbE PTM through the CMC CLI using the following command:
chassisaction –m switch-<n> powercycle
where <n> is the switch number [1-6].
2. Restart the software update process.
Section 3.7.2
for details.
Rev 1.00
25

Advertisement

Table of Contents
loading

Table of Contents