PDG-DSU30 Basic Serial Command Specifications
7.4
Input Source Read Command
COMMAND
"CR1" [CR]
Detail
Get currently selected Input
Acceptable
Response
Unacceptable
7.5
Lamp Time Read Command
COMMAND
"CR3" [CR]
Detail
Get total lamp running hours
Acceptable
Response
%1, %2
Unacceptable
7.6
Setting Read Command
COMMAND
"CR4" [CR]
Detail
Get screen setting status of Ceiling/Rear.
Acceptable
Response
Unacceptable
"%1" [CR]
"1" = Selected. Computer
%1
"2" = Selected. Video
"3" = Selected. S-video
"?" [CR]
"%1" [CR]
Each lamp data follows in sequence with one space between
each of them.
%1 = lamp No.1
e.g.; "00410" [CR]
▪▪▪▪ → Lamp No.1 = 410 Hours
"?" [CR]
"%1" [CR]
"11" [CR] = Normal Screen Setting(Status: Desktop Front)
"01" [CR] = Picture is left/right reversed (Status: Desktop Rear)
"10" [CR] = Picture is top/bottom reversed (Status: Ceiling Rear)
%1
"00" [CR] = Picture is top/bottom and left/right reversed
(Status: Ceiling Front
"?" [CR]