Raid Levels; Raid Level Comparison - HP AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive Installation Manual

Modular smart array
Hide thumbs Also See for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive:
Table of Contents

Advertisement

Vertical striping—Offers ultimate fault tolerance and performance, but at the price of storage
efficiency.
Horizontal striping—Allows for the creation of large arrays and efficient use of storage capacity,
but at the price of I/O performance and less fault tolerance.
In a vertical configuration, an array uses hard drives from separate storage enclosures and different
SCSI buses. In a horizontal configuration, the array uses multiple drives contained within the same
storage enclosure.

RAID levels

In conjunction with the striping method, the assigned RAID level also determines the fault-tolerance,
I/O performance, and storage efficiency of the LUN.
See
Table 4
below for a comparison list of the different RAID levels.
When selecting a RAID level for a LUN, consider the type of data that will be stored on the array.
For example:
For transitional data: you may want to use RAID 0, which provides no fault tolerance, but
provides rapid storage and access of large amounts of data.
For critical data: use a fault-tolerant RAID level such as RAID 1, RAID 1+0, RAID 5, or RAID 6.
Choose the RAID level that offers the desired combination of fault-tolerance, I/O performance,
and storage efficiency.
Depending on the assigned RAID level, one or more drives within a LUN can fail without bringing
the drive sub-system down.
Table 4

RAID level comparison

RAID level
Alternative name
RAID 0
Data striping
RAID 1
Drive mirroring
Data striping plus drive mirroring
RAID 1+0
RAID 5
Data striping, with one set of
distributed parity data
RAID 6
Data striping, with two sets of
distributed parity data
* Drives in the array need to be striped across separate enclosures on different SCSI buses.When drives are
selected for an array, the controller always mirrors the first half of the drives selected to the second half of the
drives selected. Therefore, if the drives selected are on a different SCSI bus or in a different enclosure, the
maximum fault tolerance levels will be realized.
26
Installation procedures—All deployments
I/O
Fault tolerance Storage
performance
Highest
None
High *
Highest *
Medium
Medium
Low
High
efficiency
Highest
Low
High
Medium

Advertisement

Table of Contents
loading

Table of Contents