Step 3: Install MSA option kits

If your plans include adding any of the available option kits for the MSA, install them now. It is
easier to install these options before racking the system.
Some of the available option kits include: additional controller cache, additional SCSI I/O module,
additional MSA controller, and additional Fibre Channel I/O module.
Remove blanking panels only for the options being installed. For proper airflow and
NOTE:
cooling, a blanking panel or component must be installed in the MSA chassis.
NOTE:
When installing an additional MSA controller, you must also obtain and install an
additional Fibre Channel I/O module. Multipath environments must include separate and complete
Fibre Channel fabrics and the associated hardware and software components, including two
controllers, two Fibre Channel I/O modules, two Fibre Channel switches, and two HBAs in each
server.
NOTE:
When installing additional SCSI I/O modules, HP recommends populating the SCSI I/O
module bays from right-to-left, so that the attached storage enclosures are added in pre-assigned
box-number order. See
For information about installing the options, see the instructions that came with the option kit.
Go to
Table
12:
30
Installation procedures—All deployments
"Recommended SCSI cable
"MSA1500
information" on page 108 to record information about your option kits.
connections" on page 42 for more information.