Dell PowerConnect J-EX8208 Hardware Manual

Powerconnect j-series ethernet switch
Hide thumbs Also See for PowerConnect J-EX8208:
Table of Contents

Advertisement

Quick Links

Dell PowerConnect J-Series
J-EX8208 Ethernet Switch
Hardware Guide
Published: 2010-10-05

Advertisement

Table of Contents
loading

Summary of Contents for Dell PowerConnect J-EX8208

  • Page 1 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Published: 2010-10-05...
  • Page 2 Information in this document is subject to change without notice. All rights reserved. Reproduction of these materials in any manner whatsoever without the written permission of Dell, Inc. is strictly forbidden. Trademarks used in this text: Dell™, the DELL™ logo, and PowerConnect™...
  • Page 3 For complete product documentation, please see the Juniper Networks Web site at www.juniper.net/techpubs. END USER LICENSE AGREEMENT READ THIS END USER LICENSE AGREEMENT (“AGREEMENT”) BEFORE DOWNLOADING, INSTALLING, OR USING THE SOFTWARE. BY DOWNLOADING, INSTALLING, OR USING THE SOFTWARE OR OTHERWISE EXPRESSING YOUR AGREEMENT TO THE TERMS CONTAINED HEREIN, YOU (AS CUSTOMER OR IF YOU ARE NOT THE CUSTOMER, AS A REPRESENTATIVE/AGENT AUTHORIZED TO BIND THE CUSTOMER) CONSENT TO BE BOUND BY THIS AGREEMENT.
  • Page 4 without first purchasing the applicable license(s) and obtaining a valid key from Juniper, even if such feature, function, service, application, operation, or capability is enabled without a key; (g) distribute any key for the Software provided by Juniper to any third party; (h) use the Software in any manner that extends or is broader than the uses purchased by Customer from Juniper or an authorized Juniper reseller;...
  • Page 5 12. Commercial Computer Software. The Software is “commercial computer software” and is provided with restricted rights. Use, duplication, or disclosure by the United States government is subject to restrictions set forth in this Agreement and as provided in DFARS 227.7201 through 227.7202-4, FAR 12.212, FAR 27.405(b)(2), FAR 52.227-19, or FAR 52.227-14(ALT III) as applicable. 13.
  • Page 7: Table Of Contents

    Chapter 1 Dell PowerConnect J-Series J-EX8208 Switch Overview ....3 J-EX8208 Switch Hardware Overview ........3 Software .
  • Page 8 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Line Card LEDs in a J-EX8200 Switch ........30 Network Port LEDs in a J-EX8200 Switch .
  • Page 9 Table of Contents Part 3 Installing and Connecting the Switch and Switch Components Chapter 8 Installing the Switch ..........89 Installing and Connecting a J-EX8208 Switch .
  • Page 10 Support Service ..........189 Dell Enterprise Training and Certification ....... 189 Problems With Your Order .
  • Page 11 Table of Contents Part 7 Safety Information Chapter 16 General Safety Information ........207 General Safety Guidelines and Warnings for J-EX Series Switches .
  • Page 12 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Non-Regulatory Environmental Standards ......248 Compliance Statements for Acoustic Noise for J-EX Series Switches ..248 Declarations of Conformity for J-EX8208 Switches .
  • Page 13: About This Guide

    This guide, the Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide, covers the Dell PowerConnect J-Series J-EX8208 switch. To download the Dell PowerConnect J-EX Series documentation listed in Table 1 on page xiii, see the following Dell support website: http://www.support.dell.com/manuals...
  • Page 14: Downloading Software

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Downloading Software You can download Junos OS for J-EX Series switches from the Download Software area http://www.support.dell.com/ . To download the software, you must have a Juniper Networks user account. For information about obtaining an account, see http://www.support.dell.com...
  • Page 15: Repair And Warranty

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  • Page 16 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide...
  • Page 17: Switch And Components Overview And Specifications

    PART 1 Switch and Components Overview and Specifications Dell PowerConnect J-Series J-EX8208 Switch Overview on page 3 Component Descriptions on page 15 Component Specifications on page 43...
  • Page 18 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide...
  • Page 19: Dell Powerconnect J-Series J-Ex8208 Switch Overview

    Switches and PowerConnect J-Series J-EX8200 Ethernet Switches—run under Junos OS, which provides Layer 2 and Layer 3 switching, routing, and security services. The same Junos OS code base that runs on J-EX Series switches also runs on Dell PowerConnect J-SRX Series Services Gateways.
  • Page 20: Chassis Physical Specifications

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Chassis Physical Specifications The J-EX8208 switch is 14 rack units (14 U) in size (1/3 rack); three J-EX8208 switches can fit in a standard 42 U rack. Each J-EX8208 switch is designed to optimize rack space and cabling.
  • Page 21: Routing Engines And Switch Fabric

    Chapter 1: Dell PowerConnect J-Series J-EX8208 Switch Overview Routing Engines and Switch Fabric Switching functionality, system management, and system control functions of a J-EX8208 switch are performed by the Switch Fabric and Routing Engine (SRE) module. See “Switch Fabric and Routing Engine (SRE) Module in a J-EX8208 Switch” on page 22. An SRE module contains a Routing Engine and switch fabric.
  • Page 22: J-Ex8208 Switch Configurations

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide The 2000 W AC power supplies support both low-line (100–120 VAC) and high-line (200–240 VAC) AC power configurations on a J-EX8208 switch. Each 2000 W AC power supply delivers 2000 W of power at high line (200–240 VAC) or 1200 W at low line (100–120 VAC) to the J-EX8208 chassis.
  • Page 23: Chassis Physical Specifications Of A J-Ex8208 Switch

    Chapter 1: Dell PowerConnect J-Series J-EX8208 Switch Overview NOTE: If you want to purchase additional AC power supplies for your switch configuration, you must order them separately. Related Chassis Physical Specifications of a J-EX8208 Switch on page 7 Documentation Switch Fabric and Routing Engine (SRE) Module in a J-EX8208 Switch on page 22...
  • Page 24 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Figure 2: J-EX8208 Switch You can mount a J-EX8200 switch on a standard 19-in. four-post rack or a standard 800-mm enclosed cabinet. Up to three J-EX8208 switches can be installed in a standard (42 rack unit (U)) rack provided the rack can handle their combined weight.
  • Page 25: Understanding J-Ex8208 Switch Component And Functionality Redundancy

    Chapter 1: Dell PowerConnect J-Series J-EX8208 Switch Overview Mounting a J-EX8208 Switch on a Rack or Cabinet on page 101 Installing and Removing J-EX8208 Switch Hardware Components on page 113 Understanding J-EX8208 Switch Component and Functionality Redundancy The J-EX8208 Ethernet switch is available as a fully redundant system. A redundant J-EX8208 switch configuration is designed so that no single point of failure can cause the entire switch to fail.
  • Page 26: Routing Engine And Control Redundancy

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide The fan tray continues to operate indefinitely and provides sufficient cooling even when a single fan fails provided the room temperature is within the operating range. See “Cooling System and Airflow in a J-EX8208 Switch” on page 38.
  • Page 27: Slot Numbering For A J-Ex8208 Switch

    Chapter 1: Dell PowerConnect J-Series J-EX8208 Switch Overview Slot Numbering for a J-EX8208 Switch A J-EX8208 chassis accepts eight line cards, two Switch Fabric and Routing Engine (SRE) modules, one Switch Fabric (SF) module, one fan tray, and six AC power supplies. All 11 slots for the line cards and the modules run horizontally across the front of the chassis.
  • Page 28 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Figure 3: Slot Numbering for a J-EX8208 Switch Slots 0 through 7 accept one of the line cards available. See “Installing a Line Card in a J-EX8200 Switch” on page 122. Slots SRE0 and SRE1 accept only the SRE module. You can install one SRE module or two SRE modules based on the configuration of your switch.
  • Page 29: Slot Numbering For The Power Supply Slots

    Chapter 1: Dell PowerConnect J-Series J-EX8208 Switch Overview Slot Numbering for the Power Supply Slots The chassis has six vertical slots on its front bottom. You can install up to six power supplies in these slots, which are labeled PSU 0 through PSU 5 (from left to right). Table 9 on page 13 lists the slot numbers for the power supplies on a J-EX8208 switch.
  • Page 30 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide 48-port SFP Line Card in a J-EX8200 Switch on page 28 48-port RJ-45 Line Card in a J-EX8200 Switch on page 29 J-EX8208 Switch Hardware Overview on page 3...
  • Page 31: Component Descriptions

    CHAPTER 2 Component Descriptions LCD Panel in a J-EX8200 Switch on page 15 Chassis Status LEDs in a J-EX8200 Switch on page 20 Field-Replaceable Units in a J-EX8208 Switch on page 21 Switch Fabric and Routing Engine (SRE) Module in a J-EX8208 Switch on page 22 SRE Module LEDs in a J-EX8208 Switch on page 23 Management Port LEDs in J-EX8200 Switches on page 25 Switch Fabric (SF) Module in a J-EX8208 Switch on page 25...
  • Page 32: Lcd Panel Modes

    Menu Enter button are disabled. For instructions, see the Dell PowerConnect J-Series Ethernet Switch Complete Software Guide for Junos OS at http://www.support.dell.com/manuals The LCD panel has a backlight. If the LCD panel is idle for 60 seconds, the backlight turns off.
  • Page 33: Lcd Panel Menus

    Chapter 2: Component Descriptions The maintenance mode allows you to cycle through options for configuring and troubleshooting the switch: System halt Reboot system Load rescue configuration Revert to factory configuration EZSetup LCD Panel Menus The LCD has three menus: Idle, Status, and Maintenance. In each of these menus, line one of the LCD panel displays the hostname of the switch.
  • Page 34 Switch fabric status option. Menu If you do not want users to use Status menu options, disable the entire menu or individual menu options. For instructions, see the Dell PowerConnect J-Series Ethernet Switch Complete Software Guide for Junos OS at http://www.support.dell.com/manuals...
  • Page 35 Menu If you do not want users to use Maintenance menu options, disable the entire menu or individual menu options. For instructions, see the Dell PowerConnect J-Series Ethernet Switch Complete Software Guide for Junos OS at http://www.support.dell.com/manuals You can view the information about the LCD panel in J-EX8200 switches by executing the command .
  • Page 36: Chassis Status Leds In A J-Ex8200 Switch

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Chassis Status LEDs in a J-EX8200 Switch The top front of the chassis of a J-EX8200 switch has three LEDs on the right side of the LCD panel. See Figure 6 on page 20.
  • Page 37: Field-Replaceable Units In A J-Ex8208 Switch

    Chapter 2: Component Descriptions For information about alarm types and severity levels on the switch, see the Dell PowerConnect J-Series Ethernet Switch Complete Software Guide for Junos OS at http://www.support.dell.com/manuals Field-Replaceable Units in a J-EX8208 Switch Field-replaceable units (FRUs) are switch components that you can replace at your site.
  • Page 38: Switch Fabric And Routing Engine (Sre) Module In A J-Ex8208 Switch

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Removing a Line Card from a J-EX8200 Switch on page 170 Removing an AC Power Supply from a J-EX8200 Switch on page 161 Removing a Fan Tray from a J-EX8208 Switch on page 163...
  • Page 39: Sre Module Leds In A J-Ex8208 Switch

    Chapter 2: Component Descriptions Powers the line cards on and off Controls system resets and boot sequence for the switch Monitors and controls the fan speed, power status for various chassis components, LCD panel and chassis status LEDs The SRE module has these components: SRE module LEDs—Indicate system status.
  • Page 40 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Figure 8: SRE Module LEDs in a J-EX8208 Switch Table 13: SRE Module LEDs of a J-EX8208 Switch LED Label (Description) Color State and Description ON (Power On) Green SRE module is powered on.
  • Page 41: Management Port Leds In J-Ex8200 Switches

    Chapter 2: Component Descriptions Management Port LEDs in J-EX8200 Switches The management port on J-EX8200 switches has two LEDs that indicate link/activity and port status (see Figure 9 on page 25). The management port is set to full-duplex and the speed is set to 100 Mbps. Figure 9: LEDs on the Management Port on a J-EX8200 Switch Table 14 on page 25 describes the Link/Activity LED.
  • Page 42: Sf Module Leds In A J-Ex8208 Switch

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide A redundant J-EX8208 switch has one SF module. Figure 10: SF Module in a J-EX8208 Switch The SF module can be installed only in the slot labeled SF. The SF module is keyed so that it does not fit in the other slots in the chassis.
  • Page 43: 8-Port Sfp+ Line Card In A J-Ex8200 Switch

    Chapter 2: Component Descriptions Figure 11: SF Module LEDs in a J-EX8208 Switch Table 16: SF Module LEDs of a J-EX8208 Switch LED (Description) Color State and Description ST (Status) Green On steadily—SF module is operating normally. Blinking—Waiting to be configured by the master Switch Fabric and Routing Engine (SRE) module.
  • Page 44: 48-Port Sfp Line Card In A J-Ex8200 Switch

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide You can use any combination of line cards in a J-EX8200 switch. The 8-port SFP+ line card for J-EX8200 switches (see Figure 12 on page 28) has eight 10-gigabit SFP+ ports on the faceplate in which you can install SFP+ transceivers. The line card is shipped with dust covers preinstalled in the ports.
  • Page 45: 48-Port Rj-45 Line Card In A J-Ex8200 Switch

    Chapter 2: Component Descriptions card is shipped with 48 dust covers (in the accessory bag). Each port has two LEDs. See “Network Port LEDs in a J-EX8200 Switch” on page 31. Figure 13: 48-port SFP Line Card The line card has two status LEDs labeled ON and ST on the faceplate that indicate the online and status information for the line card.
  • Page 46: Line Card Leds In A J-Ex8200 Switch

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Figure 14: 48-port RJ-45 Line Card The line card has two status LEDs labeled ON and ST on the faceplate that indicate the online and status information for the line card. See “Line Card LEDs in a J-EX8200 Switch”...
  • Page 47: Network Port Leds In A J-Ex8200 Switch

    Chapter 2: Component Descriptions Figure 17: Status LEDs on 48-port RJ-45 Line Card Table 17 on page 31 describes the status LEDs on line cards for the J-EX8200 switch, their colors and state, and the status they indicate. Table 17: Status LEDs on Line Cards for J-EX8200 Switches Color State and Description Green...
  • Page 48 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Figure 18: Network Port LEDs on an 8-port SFP+ Line Card Figure 19 on page 32 shows the network port LEDs on a 48-port SFP line card. The LEDs point toward the port to which the LEDs belong.
  • Page 49 Chapter 2: Component Descriptions Table 18: Network Port LEDs on Line Cards in a J-EX8200 Switch—Link/Activity LED Color State and Description Link/Activity Green On steadily—The port and the link are active, but there is no link activity. Blinking—The port and the link are active, and there is link activity.
  • Page 50: Ac Power Supply In A J-Ex8200 Switch

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Line Card LEDs in a J-EX8200 Switch on page 30 LCD Panel in a J-EX8200 Switch on page 15 AC Power Supply in a J-EX8200 Switch This topic describes the AC power supplies in J-EX8200 switches:...
  • Page 51: N+1 Redundancy Configuration Of Ac Power Supplies

    Chapter 2: Component Descriptions Each AC power supply comes with a power retainer that holds the power cord in place. See Figure 22 on page 35. The power retainer has a clip and an adjustment nut. The L-shaped ends of the clip hook into the bracket holes on each side of the AC appliance inlet on the faceplate.
  • Page 52: N+N Redundancy Configuration Of Ac Power Supplies

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Table 20: N+1 Power Redundancy Configurations for Different J-EX8208 Switch Configurations Using 2000 W AC Power Supplies Switch Power Supplies Power Supplies Configuration Input Voltage Needed (N) Needed for N+1 No line cards High line (200–240 VAC)
  • Page 53: Ac Power Supply Leds In A J-Ex8200 Switch

    Chapter 2: Component Descriptions Calculating Power Requirements for a J-EX8208 Switch on page 79 Installing an AC Power Supply in a J-EX8200 Switch on page 114 Removing an AC Power Supply from a J-EX8200 Switch on page 161 AC Power Supply LEDs in a J-EX8200 Switch An AC power supply has three LEDs on its faceplate.
  • Page 54: Cooling System And Airflow In A J-Ex8208 Switch

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Table 22: Power Supply LEDs on J-EX8200 Switches (continued) State Description OUTPUT OK Unlit Indicates one of the following: DC output voltage is not within normal operating range. Power supply is not supplying DC power correctly.
  • Page 55 Chapter 2: Component Descriptions Figure 24: Fan Tray for a J-EX8208 Switch Fans Handle Spring-loaded latch The fan tray can be removed and replaced from the front of the chassis. The switch continues to operate for a limited time (2 minutes) during the replacement of the fan tray without thermal shutdown.
  • Page 56 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Figure 25: Airflow Through the J-EX8208 Switch Chassis The Switch Fabric and Routing Engine (SRE) module monitors the temperature of switch components. Under normal operating conditions, the fans in the fan tray run at less than full speed.
  • Page 57: Backplane In A J-Ex8208 Switch

    Chapter 2: Component Descriptions Related Field-Replaceable Units in a J-EX8208 Switch on page 21 Documentation Installing a Fan Tray in a J-EX8208 Switch on page 116 Removing a Fan Tray from a J-EX8208 Switch on page 163 Backplane in a J-EX8208 Switch The backplane is a printed circuit board that forms the back of the line card cage.
  • Page 58 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide...
  • Page 59: Component Specifications

    Documentation for port location. For information about booting the switch from a software package installed on a USB flash drive, see the the Dell PowerConnect J-Series Ethernet Switch Complete Software Guide for Junos OS at http://www.support.dell.com/manuals Console Port Connector Pinout Information for a J-EX Series Switch The console port on a J-EX Series switch is an RS-232 serial interface that uses an RJ-45 connector to connect to a console management device.
  • Page 60: Management Port Connector Pinout Information For A J-Ex8200 Switch

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Table 23 on page 44 provides the pinout information for the RJ-45 console connector. An RJ-45 cable and an RJ-45 to DB-9 serial port adapter are supplied with the switch. NOTE: If your laptop or PC does not have a DB-9 male connector pin and you...
  • Page 61: Optical Interface Support In J-Ex8200 Switches

    SFP transceivers. NOTE: Use only optical transceivers and optical connectors purchased from Dell for your J-EX Series switch. The Gigabit Ethernet SFP and SFP+ transceivers installed in J-EX8200 switches support digital optical monitoring (DOM): you can view the diagnostic details for these transceivers by issuing the operational mode CLI command .
  • Page 62 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Table 26 on page 49—Optical interface support and copper interface support for SFP transceivers in 48-port SFP line cards Table 25: Optical Interface Support for SFP+ Transceivers in 8-port SFP+ Line Cards Used in...
  • Page 63 Chapter 3: Component Specifications Table 25: Optical Interface Support for SFP+ Transceivers in 8-port SFP+ Line Cards Used in J-EX8200 Switches (continued) Ethernet Standard Specifications 10GBase-LRM Model Number EX-SFP-10GE-LRM Rate 10 Gbps Connector Type Fiber Count Dual Transmitter Wavelength 1310 nm Minimum Launch Power –6.5 dBm Maximum Launch Power...
  • Page 64 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Table 25: Optical Interface Support for SFP+ Transceivers in 8-port SFP+ Line Cards Used in J-EX8200 Switches (continued) Ethernet Standard Specifications 10GBase-LR Model Number EX-SFP-10GE-LR Rate 10 Gbps Connector Type Transmitter Wavelength...
  • Page 65 Chapter 3: Component Specifications Table 26: Optical Interface Support and Copper Interface Support for SFP Transceivers in 48-port SFP Line Cards Used in J-EX8200 Switches Ethernet Standard Specifications 1000Base-T Model Number EX-SFP-1GE-T Rate 10/100/1000 Mbps Connector Type RJ-45 Transmitter Wavelength –...
  • Page 66 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Table 26: Optical Interface Support and Copper Interface Support for SFP Transceivers in 48-port SFP Line Cards Used in J-EX8200 Switches (continued) Ethernet Standard Specifications 1000Base-SX Model Number EX-SFP-1GE-SX Rate 1000 Mbps...
  • Page 67 Chapter 3: Component Specifications Table 26: Optical Interface Support and Copper Interface Support for SFP Transceivers in 48-port SFP Line Cards Used in J-EX8200 Switches (continued) Ethernet Standard Specifications 100Base-FX Model Number EX-SFP-1FE-FX Rate 100 Mbps Connector Type Transmitter Wavelength 1310 nm Minimum Launch Power –20 dBm...
  • Page 68 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Table 26: Optical Interface Support and Copper Interface Support for SFP Transceivers in 48-port SFP Line Cards Used in J-EX8200 Switches (continued) Ethernet Standard Specifications 1000Base-LX Model Number EX-SFP-1GE-LX Rate 1000 Mbps...
  • Page 69: Grounding Cable And Lug Specifications For J-Ex8200 Switches

    48-port SFP Line Card in a J-EX8200 Switch on page 28 48-port RJ-45 Line Card in a J-EX8200 Switch on page 29 show interfaces diagnostics optics command syntax, see the Dell PowerConnect J-Series Ethernet Switch Complete Software Guide for Junos OS at http://www.support.dell.com/manuals...
  • Page 70 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide J-EX8200 switch, connect a grounding cable to earth ground and then attach it to the chassis grounding points. CAUTION: For installations that require a separate grounding conductor to the chassis, use the protective earthing terminal on the J-EX8200 switch chassis to connect to earth ground.
  • Page 71: Planning For Switch Installation

    PART 2 Planning for Switch Installation Site Preparation on page 57 Rack and Cabinet Requirements on page 63 Cable Requirements on page 71 Planning Power Requirements on page 75...
  • Page 72 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide...
  • Page 73: Site Preparation

    CHAPTER 4 Site Preparation Site Preparation Checklist for a J-EX8200 Switch on page 57 General Site Guidelines for J-EX Series Switches on page 58 Site Electrical Wiring Guidelines for J-EX Series Switches on page 59 Environmental Requirements and Specifications for J-EX Series Switches on page 60 Site Preparation Checklist for a J-EX8200 Switch The checklist in Table 27 on page 57 summarizes the tasks you need to perform to prepare a site for installing a J-EX8200 switch.
  • Page 74: General Site Guidelines For J-Ex Series Switches

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Table 27: Site Preparation Checklist (continued) Item or Task For More Information Performed By Date Rack or Cabinet Select the type of rack or cabinet and verify that “Rack Requirements for a J-EX8208 it meets the minimum requirements for the Switch”...
  • Page 75: Site Electrical Wiring Guidelines For J-Ex Series Switches

    Chapter 4: Site Preparation Follow the prescribed ESD prevention procedures to avoid damaging the equipment. Static discharge can cause components to fail completely or intermittently over time. Install the switch in a secure area, so that only authorized personnel can access the switch.
  • Page 76: Environmental Requirements And Specifications For J-Ex Series Switches

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Table 28: Site Electrical Wiring Guidelines (continued) Site Wiring Factor Guidelines Electromagnetic compatibility If your site is susceptible to problems with electromagnetic compatibility (EMC), particularly from lightning or radio transmitters, seek expert advice.
  • Page 77 Chapter 4: Site Preparation Table 29: J-EX Series Switch Environmental Tolerances (continued) Description Tolerance Seismic Complies with Zone 4 earthquake requirements as per GR-63, Issue NOTE: Install J-EX Series switches only in restricted areas, such as dedicated equipment rooms and equipment closets, in accordance with Articles 110–16, 110–17, and 110–18 of the National Electrical Code, ANSI/NFPA 70.
  • Page 78 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide...
  • Page 79: Rack And Cabinet Requirements

    CHAPTER 5 Rack and Cabinet Requirements Rack Requirements for a J-EX8208 Switch on page 63 Cabinet Requirements and Specifications for a J-EX8208 Switch on page 66 Clearance Requirements for Airflow and Hardware Maintenance for a J-EX8208 Switch on page 67 Rack Requirements for a J-EX8208 Switch You can mount J-EX8208 switches on four-post racks or two-post racks.
  • Page 80 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Table 30: Rack Requirements and Specifications for a J-EX8208 Switch Rack Requirement Guidelines Rack type and mounting bracket hole Use a four-post rack or a two-post rack. You can mount the switch on any four-post spacing or two-post rack that provides bracket holes or hole patterns spaced at 1 U (1.75...
  • Page 81 Chapter 5: Rack and Cabinet Requirements Figure 27: Installing a J-EX8208 Switch in a Four-Post Rack Figure 28: Installing a J-EX8208 Switch in a Two-Post Rack Related Rack-Mounting and Cabinet-Mounting Warnings for J-EX Series Switches on page 221 Documentation Cabinet Requirements and Specifications for a J-EX8208 Switch on page 66 Chassis Physical Specifications of a J-EX8208 Switch on page 7...
  • Page 82: Cabinet Requirements And Specifications For A J-Ex8208 Switch

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Cabinet Requirements and Specifications for a J-EX8208 Switch You can mount a J-EX8208 switch on a cabinet that contains a 19-in. rack as defined in Cabinets, Racks, Panels, and Associated Equipment (document number EIA-310-D) published by the Electronics Industry Association ( http://www.eia.org...
  • Page 83: Clearance Requirements For Airflow And Hardware Maintenance For A J-Ex8208

    Chapter 5: Rack and Cabinet Requirements Table 31: Cabinet Requirements and Specifications for a J-EX8208 Switch (continued) Cabinet Requirement Guidelines for the J-EX8208 Switch Cabinet airflow requirements When you mount the switch on a cabinet, ensure that ventilation through the cabinet is sufficient to prevent overheating.
  • Page 84 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Figure 29: Airflow Through the J-EX8208 Switch Chassis If you are mounting the switch on a rack or cabinet along with other equipment, ensure that the exhaust from other equipment does not blow into the intake vents of the chassis.
  • Page 85 Chapter 5: Rack and Cabinet Requirements Figure 30: Clearance Requirements for Airflow and Hardware Maintenance for a J-EX8208 Switch Chassis Related Cabinet Requirements and Specifications for a J-EX8208 Switch on page 66 Documentation Rack Requirements for a J-EX8208 Switch on page 63 Rack-Mounting and Cabinet-Mounting Warnings for J-EX Series Switches on page 221 Cooling System and Airflow in a J-EX8208 Switch on page 38...
  • Page 86 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide...
  • Page 87: Cable Requirements

    CHAPTER 6 Cable Requirements Cables Connecting the J-EX8200 Switch to Management Devices on page 71 Understanding J-EX8200 Switch Fiber-Optic Cable Signal Loss, Attenuation, and Dispersion on page 72 Cables Connecting the J-EX8200 Switch to Management Devices Table 32 on page 71 lists the specifications for the cables that connect the Switch Fabric and Routing Engine (SRE) module in the switch to a management device.
  • Page 88: Understanding J-Ex8200 Switch Fiber-Optic Cable Signal Loss, Attenuation, And Dispersion

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Understanding J-EX8200 Switch Fiber-Optic Cable Signal Loss, Attenuation, and Dispersion To determine the power budget and power margin needed for fiber-optic connections, you need to understand how signal loss, attenuation, and dispersion affect transmission.
  • Page 89 Chapter 6: Cable Requirements Modal dispersion, which is the spreading of the signal over time caused by the different propagation modes in the fiber. For multimode transmission, modal dispersion, rather than chromatic dispersion or attenuation, usually limits the maximum bit rate and link length. For single-mode transmission, modal dispersion is not a factor.
  • Page 90 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide...
  • Page 91: Planning Power Requirements

    CHAPTER 7 Planning Power Requirements AC Power Specifications for J-EX8200 Switches on page 75 Power Requirements for J-EX8208 Switch Components on page 76 AC Power Cord Specifications for a J-EX8200 Switch on page 76 Calculating Power Requirements for a J-EX8208 Switch on page 79 Calculating the J-EX8200 Switch Fiber-Optic Cable Power Budget on page 84 Calculating the J-EX8200 Switch Fiber-Optic Cable Power Margin on page 85 AC Power Specifications for J-EX8200 Switches...
  • Page 92: Power Requirements For J-Ex8208 Switch Components

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Power Requirements for J-EX8208 Switch Components Table 34 on page 76 lists the power requirements for different hardware components of a J-EX8208 switch under typical voltage conditions. Table 34: J-EX8208 Switch Component Power Requirements...
  • Page 93 Chapter 7: Planning Power Requirements NOTE: In North America, AC power cords must not exceed 4.5 meters (approximately 15 feet) in length, to comply with National Electrical Code (NEC) Sections 400-8 (NFPA 75, 5-2.2) and 210-52 and Canadian Electrical Code (CEC) Section 4-010(3). The cords separately orderable as FRUs are in compliance.
  • Page 94 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Table 35: AC Power Cord Specifications for a J-EX8200 Switch (continued) Country/Region Electrical Specifications Plug Standards United Kingdom 250 VAC, 13 A, 50 Hz BS 1363/A Figure 31 on page 78 shows the plug on the power cord for many of the countries and regions listed in Table 35 on page 77.
  • Page 95: Calculating Power Requirements For A J-Ex8208 Switch

    Chapter 7: Planning Power Requirements WARNING: The switch is pluggable type A equipment installed in a restricted-access location. It has a separate protective earthing terminal provided on the chassis in addition to the grounding pin of the power supply cord. This separate protective earth terminal must be permanently connected to earth ground.
  • Page 96 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Use Table 36 on page 80 if your switch has power management configured for N+1 power redundancy. Use Table 37 on page 80 if your switch has power management configured for N+N power redundancy.
  • Page 97: Calculating System Thermal Output For Your J-Ex8208 Switch Configuration

    Chapter 7: Planning Power Requirements Calculate the maximum system power consumption by dividing the maximum internal power consumption by the efficiency of the power supply. This accounts for the loss of energy within the power supply. NOTE: The efficiency of a 2000 W AC power supply is approximately 90 percent when input voltage is high line (200–240 VAC).
  • Page 98 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide To calculate the number of power supplies required for your switch configuration: Determine the power requirement of the chassis—with the fan tray, SRE modules, and SF module, but no line cards—by consulting Table 38 on page 82.
  • Page 99 Chapter 7: Planning Power Requirements NOTE: If the input voltage is high line (200–220 VAC), the output wattage of a 2000 W AC power supply is 2000 W. If the input voltage is low line (100–120 VAC), the output wattage of a 2000 W AC power supply is 1200 W.
  • Page 100: Calculating The J-Ex8200 Switch Fiber-Optic Cable Power Budget

    Related AC Power Supply in a J-EX8200 Switch on page 34 Documentation For more information about power management on the switch, see the Dell PowerConnect J-Series Ethernet Switch Complete Software Guide for Junos OS at http://www.support.dell.com/manuals Calculating the J-EX8200 Switch Fiber-Optic Cable Power Budget Calculate the link's power budget when planning fiber-optic cable layout and distances to ensure that fiber-optic connections have sufficient power for correct operation.
  • Page 101: Calculating The J-Ex8200 Switch Fiber-Optic Cable Power Margin

    Chapter 7: Planning Power Requirements Calculate the power budget ( ) by subtracting ( ) from ( –15 dBm – (–28 dBm) = 13 dBm Related Calculating the J-EX8200 Switch Fiber-Optic Cable Power Margin on page 85 Documentation Optical Interface Support in J-EX8200 Switches on page 45 Understanding J-EX8200 Switch Fiber-Optic Cable Signal Loss, Attenuation, and Dispersion on page 72 Calculating the J-EX8200 Switch Fiber-Optic Cable Power Margin...
  • Page 102 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Table 39: Estimated Values for Factors Causing Link Loss (continued) Link-Loss Factor Estimated Link-Loss Value Sample (LL) Calculation Values Connector 0.5 dBm This example assumes 5 connectors. Loss for 5 connectors: 5(0.5 dBm) = 2.5 dBm Splice 0.5 dBm...
  • Page 103 PART 3 Installing and Connecting the Switch and Switch Components Installing the Switch on page 89 Installing Switch Components on page 113 Connecting the Switch on page 129 Performing Initial Configuration on page 143...
  • Page 104 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide...
  • Page 105: Installing The Switch

    CHAPTER 8 Installing the Switch Installing and Connecting a J-EX8208 Switch on page 89 Unpacking a J-EX8200 Switch on page 90 Parts Inventory (Packing List) for a J-EX8208 Switch on page 92 Installing Adjustable Mounting Brackets in a Rack or Cabinet for a J-EX8200 Switch on page 95 Installing the Power Cord Tray in a Rack or Cabinet for a J-EX8200 Switch on page 98 Mounting a J-EX8208 Switch on a Rack or Cabinet on page 101...
  • Page 106: Unpacking A J-Ex8200 Switch

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide To connect the switch to a network for out-of-band management, follow instructions in “Connecting a J-EX Series Switch to a Network for Out-of-Band Management” on page 140. To connect the switch to a management console, follow instructions in “Connecting a J-EX Series Switch to a Management Console”...
  • Page 107 Chapter 8: Installing the Switch Figure 32: Pallet Fastener Carefully slice open the tape that holds the top of the cardboard box closed and open the top of the box. Remove the cardboard accessory box from the center of the foam padding. Remove the foam padding from the top of the box.
  • Page 108: Parts Inventory (Packing List) For A J-Ex8208 Switch

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Figure 33: Unpacking a J-EX8208 Switch Related Mounting a J-EX8208 Switch on a Rack or Cabinet on page 101 Documentation Parts Inventory (Packing List) for a J-EX8208 Switch The switch shipment includes a packing list. Check the parts you receive in the switch shipping crate against the items on the packing list.
  • Page 109: Switch

    If you have a problem with your order, such as missing parts, wrong parts, or incorrect billing, contact Dell for customer assistance. Have your invoice or packing slip handy when you call. For the telephone number to call for your region, see “Contacting Dell” on page 191.
  • Page 110 Dell PowerConnect Safety, Environmental, and Regulatory Information End User License Agreement DellPowerConnect Warranty and Support Information Registration and Software Updates for Your Dell PowerConnect J-Series Product Open Source Code Notice Ethernet cable, RJ-45/RJ-45, 4-pair stranded UTP, category #5 RJ-45 to female DB-9 cable, to connect to the switch's console port using a management PC's serial port...
  • Page 111 Chapter 8: Installing the Switch Installing Adjustable Mounting Brackets in a Rack or Cabinet for a J-EX8200 Switch To mount the switch on a four-post rack or cabinet, you must first install the adjustable mounting brackets in the rack or cabinet. (The remainder of this topic uses “rack” to mean “rack or cabinet.”) The J-EX8200 switch comes with a four-piece set of adjustable mounting brackets that supports the chassis in the rack.
  • Page 112 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide page 63 and “Cabinet Requirements and Specifications for a J-EX8208 Switch” on page 66. If your rack has unthreaded round or square holes, install 8 cage nuts in the appropriate holes on the left front and left rear rack posts, making sure that the 4 cage nuts on each post are on the same rack level front and back.
  • Page 113 Chapter 8: Installing the Switch Figure 36: Adjustable Mounting Brackets for Four-Post Rack Installation If your rack has unthreaded round or square holes, install 8 cage nuts in the appropriate holes on the right front and right rear rack posts, making sure that the 4 cage nuts on each post are on the same rack level front and back.
  • Page 114: Installing The Power Cord Tray In A Rack Or Cabinet For A J-Ex8200 Switch

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Figure 37: Adjustable Mounting Brackets Installed in a Four-Post Rack (J-EX8208 Switch) Related Mounting a J-EX8208 Switch on a Rack or Cabinet Using a Mechanical Lift on page 104 Documentation Mounting a J-EX8208 Switch on a Rack or Cabinet Without Using a Mechanical Lift on...
  • Page 115 Chapter 8: Installing the Switch NOTE: For four-post rack installation, if you install the optional power cord tray you must provide 4 mounting screws—plus 4 cage nuts and washers—that are appropriate for your rack or cabinet. To install the power cord tray (see Figure 40 on page 100 and Figure 41 on page 100): Remove the power cord tray from the accessory box.
  • Page 116 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Figure 40: Installing the Power Cord Tray in a Four-Post Rack Figure 41: Power Cord Tray Installed in a Two-Post Rack Related Mounting a J-EX8208 Switch on a Rack or Cabinet on page 101...
  • Page 117: Mounting A J-Ex8208 Switch On A Rack Or Cabinet

    Chapter 8: Installing the Switch Mounting a J-EX8208 Switch on a Rack or Cabinet The J-EX8208 switch ships installed with front-mounting brackets on the chassis for mounting the switch on a 19-in. equipment rack or cabinet. The switch also comes with adjustable mounting brackets to support it in the rack.
  • Page 118 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Ensure that you have the following parts and tools available to mount the switch on a rack or cabinet: A Phillips (+) screwdriver, number 2 or number 3, depending on the size of your rack...
  • Page 119 Chapter 8: Installing the Switch Lift the chassis into the rack using a mechanical lift. For instructions on how to install the chassis using a mechanical lift, see “Mounting a J-EX8208 Switch on a Rack or Cabinet Using a Mechanical Lift” on page 104. In a four-post rack, place the chassis on the adjustable mounting brackets.
  • Page 120: Mounting A J-Ex8208 Switch On A Rack Or Cabinet Using A Mechanical Lift

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Figure 45: Installing a J-EX8208 Switch in a Four-Post Rack Related Connecting AC Power to a J-EX8200 Switch on page 130 Documentation Rack Requirements for a J-EX8208 Switch on page 63 Cabinet Requirements and Specifications for a J-EX8208 Switch on page 66...
  • Page 121 Chapter 8: Installing the Switch Unpack the switch as described in “Unpacking a J-EX8200 Switch” on page 90. In a two-post rack, install the power cord tray at the desired position (see “Installing the Power Cord Tray in a Rack or Cabinet for a J-EX8200 Switch” on page 98). The lip of the power cord tray will support the front of the chassis when you install the switch in the two-post rack.
  • Page 122: Lift

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Figure 47: Installing a Square-Hole Cage Nut Load the switch onto the lift, making sure it rests securely on the lift platform. Figure 48: Installing the J-EX8208 Switch Chassis Using a Mechanical...
  • Page 123 Chapter 8: Installing the Switch In a four-post rack, carefully slide the switch onto the adjustable mounting brackets until the front-mounting brackets (“ears”) attached to the chassis contact the rack posts. The adjustable mounting brackets installed in the rack ensure that the holes in the front-mounting brackets align with the holes in the rack posts.
  • Page 124 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide CAUTION: Before front-mounting the switch in a rack, have a qualified technician verify that the rack is strong enough to support the switch's weight and is adequately supported at the installation site.
  • Page 125 Chapter 8: Installing the Switch To install the switch in the rack or cabinet (see Figure 52 on page 111 and Figure 53 on page 111): CAUTION: If you are installing more than one switch in a rack or cabinet, install the first one at the bottom of the rack.
  • Page 126 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Figure 51: Lifting a J-EX8208 Switch Chassis Without Using a Mechanical Lift In a four-post rack, carefully slide the switch onto the adjustable mounting brackets until the front-mounting brackets attached to the chassis contact the rack posts. The adjustable mounting brackets ensure that the holes in the front-mounting brackets attached to the chassis align with the holes in the rack posts.
  • Page 127 Chapter 8: Installing the Switch Figure 52: Installing a J-EX8208 Switch in a Four-Post Rack Figure 53: Installing a J-EX8208 Switch in a Two-Post Rack After you install the mounting screws and securely bolt the chassis to the rack, reinstall the components in the chassis.
  • Page 128 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Installing a Fan Tray in a J-EX8208 Switch on page 116 Installing an AC Power Supply in a J-EX8200 Switch on page 114 Related Powering On a J-EX8200 Switch on page 133...
  • Page 129: Installing Switch Components

    CHAPTER 9 Installing Switch Components Installing and Removing J-EX8208 Switch Hardware Components on page 113 Installing an AC Power Supply in a J-EX8200 Switch on page 114 Installing a Fan Tray in a J-EX8208 Switch on page 116 Installing an SRE Module in a J-EX8208 Switch on page 118 Installing an SF Module in a J-EX8208 Switch on page 120 Unpacking a Line Card Used in a J-EX8200 Switch on page 121 Installing a Line Card in a J-EX8200 Switch on page 122...
  • Page 130: Installing An Ac Power Supply In A J-Ex8200 Switch

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide The AC power supplies, fan tray, SFP transceiver, and SFP+ transceiver in J-EX8200 switches are hot-removable and hot-insertable FRUs: you can remove and replace them without powering off the switch or disrupting switch functions.
  • Page 131 Chapter 9: Installing Switch Components NOTE: Each AC power supply must be connected to a dedicated AC power source outlet. To install an AC power supply in a J-EX8200 switch (see Figure 54 on page 116): Attach the electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to the ESD point on the chassis.
  • Page 132: Installing A Fan Tray In A J-Ex8208 Switch

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Figure 54: Installing an AC Power Supply in a J-EX8200 Switch Related Removing an AC Power Supply from a J-EX8200 Switch on page 161 Documentation Calculating Power Requirements for a J-EX8208 Switch on page 79...
  • Page 133 Chapter 9: Installing Switch Components Electrostatic discharge (ESD) grounding strap CAUTION: The fan tray can be removed and replaced while the switch is operating. However, the fan tray must be replaced within 2 minutes of removing the fan tray to prevent the chassis from overheating. To install a fan tray in a J-EX8208 switch (see Figure 55 on page 117): Attach the electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to the ESD point on the chassis.
  • Page 134: Installing An Sre Module In A J-Ex8208 Switch

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Installing an SRE Module in a J-EX8208 Switch You can install either one or two Switch Fabric and Routing Engine (SRE) modules in a J-EX8208 switch. The SRE modules install horizontally in the front of the chassis in the slots labeled SRE0 and SRE1.
  • Page 135 Chapter 9: Installing Switch Components Tighten the screws, one on each side of the SRE module, by turning them clockwise using the Phillips (+) screwdriver, number 2. Ensure that the SRE module is fully seated in the chassis. It must be fully seated in order for it to be powered up. Verify that the SRE module is installed correctly and functioning normally by checking the LEDs on the faceplate of the SRE module.
  • Page 136: Installing An Sf Module In A J-Ex8208 Switch

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Installing an SF Module in a J-EX8208 Switch One SF module is included in the redundant J-EX8208 switch configuration. The SF module can be installed only in the slot labeled SF. The module is keyed so that it does not fit in any other slot in the chassis.
  • Page 137: Unpacking A Line Card Used In A J-Ex8200 Switch

    Chapter 9: Installing Switch Components If the LED is unlit, check whether there are enough power supplies installed. See “Calculating Power Requirements for a J-EX8208 Switch” on page 79. If more power supplies are needed, install additional power supplies. See “Installing an AC Power Supply in a J-EX8200 Switch”...
  • Page 138: Installing A Line Card In A J-Ex8200 Switch

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide CAUTION: The line cards are maximally protected inside the shipping carton. Do not unpack the line cards until you are ready to install them in the switch chassis. Before you unpack a line card: Ensure that you have taken the necessary precautions to prevent ESD damage (see “Prevention of Electrostatic Discharge Damage on J-EX Series Switches”...
  • Page 139 Chapter 9: Installing Switch Components and hot-removable: You can remove and replace them without powering off the switch or disrupting switch functions. Before you begin installing a line card in the switch: Ensure that you have taken the necessary precautions to prevent Electrostatic Discharge Damage (ESD) damage (see “Prevention of Electrostatic Discharge Damage on J-EX Series Switches”...
  • Page 140 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide of the line card. Lifting the line cards by the levers might bend them. Bent levers prevent the line cards from being properly seated in the chassis. Taking care not to touch line card components, pins, leads, or solder connections, remove the line card from its bag.
  • Page 141: Installing A Transceiver In A J-Ex Series Switch

    (FRUs): You can remove and replace them without powering off the switch or disrupting switch functions. Use only optical transceivers and optical connectors purchased from Dell for your J-EX Series switch. Before you begin installing a transceiver in a J-EX Series switch, ensure that you have taken the necessary precautions for safe handling of lasers (see “Laser and LED Safety...
  • Page 142: Connecting A Fiber-Optic Cable To A J-Ex Series Switch

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide WARNING: Do not leave a fiber-optic transceiver uncovered except when inserting or removing a cable. The rubber safety cap keeps the port clean and prevents accidental exposure to laser light. If the port in which you want to install the transceiver is covered with a dust cover, remove the dust cover and save it in case you need to cover the port later.
  • Page 143 Chapter 9: Installing Switch Components Before you begin connecting a fiber-optic cable to an optical transceiver installed in a J-EX Series switch, ensure that you have taken the necessary precautions for safe handling of lasers (see “Laser and LED Safety Guidelines and Warnings for J-EX Series Switches” on page 213).
  • Page 144 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide...
  • Page 145: Connecting The Switch

    CHAPTER 10 Connecting the Switch Connecting Earth Ground to a J-EX Series Switch on page 129 Connecting AC Power to a J-EX8200 Switch on page 130 Powering On a J-EX8200 Switch on page 133 Connecting a J-EX Series Switch to a Management Console on page 135 Connecting a J-EX Series Switch to a Modem on page 136 Connecting a J-EX Series Switch to a Network for Out-of-Band Management on page 140 Connecting Earth Ground to a J-EX Series Switch...
  • Page 146: Connecting Earth Ground To A J-Ex8208 Switch

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide CAUTION: Using a grounding cable with an incorrectly attached lug can damage the switch. Follow the procedure that applies to your switch: Connecting Earth Ground to a J-EX8208 Switch on page 130...
  • Page 147 Chapter 10: Connecting the Switch CAUTION: Mixing different types of power supplies in the same chassis is not a supported configuration. NOTE: Each power supply must be connected to a dedicated AC power source outlet. Before you begin to connect power to the switch: Ensure you understand how to prevent ESD damage.
  • Page 148 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Attach the electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to the ESD point on the chassis. Ensure that the power supply is fully inserted and latched securely in the chassis. See “Installing an AC Power Supply in a J-EX8200 Switch”...
  • Page 149: Powering On A J-Ex8200 Switch

    Chapter 10: Connecting the Switch Figure 65: Connecting the Power Supply Cord to a J-EX8200 Switch Related Powering On a J-EX8200 Switch on page 133 Documentation AC Power Supply in a J-EX8200 Switch on page 34 AC Power Supply LEDs in a J-EX8200 Switch on page 37 Powering On a J-EX8200 Switch Before you power on the switch, ensure that: You have installed all required switch components.
  • Page 150 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide device to the management port, see “Connecting a J-EX Series Switch to a Network for Out-of-Band Management” on page 140. To power on the switch: Attach the ESD grounding strap to your bare wrist and connect the strap to the ESD point on the chassis.
  • Page 151: Connecting A J-Ex Series Switch To A Management Console

    Chapter 10: Connecting the Switch NOTE: After you power on a power supply, wait for at least 60 seconds before you turn it off. After you power off a power supply, wait for at least 60 seconds before you turn it back on. If the system is completely powered off when you switch on a power supply, the SRE module boots as the power supply completes its startup sequence.
  • Page 152: Connecting A J-Ex Series Switch To A Modem

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide For the location of the CON/CONSOLE port, see “Switch Fabric and Routing Engine (SRE) Module in a J-EX8208 Switch” on page 22. Connect the other end of the Ethernet cable into the console server (see Figure 68 on page 136) or management console (see Figure 69 on page 136).
  • Page 153: Setting The Serial Console Speed For The Switch

    Chapter 10: Connecting the Switch If your computer does not have a DB-9 male connector pin, a USB to DB-9 male adapter (not provided) An adapter to connect the RS-232 DB-25 connector on the modem to the RJ-45 to DB-9 adapter on the switch (not provided) This topic describes: Setting the Serial Console Speed for the Switch on page 137 Configuring the Modem on page 138...
  • Page 154: Configuring The Modem

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Configuring the Modem Before you connect the modem, you must configure the modem with required port settings. NOTE: The following procedure uses Hayes-compatible-modem commands to configure the modem. If your modem is not Hayes-compatible, see the documentation for your modem for the equivalent modem commands.
  • Page 155: Connecting The Modem To The Console Port

    Chapter 10: Connecting the Switch NOTE: You must set the serial port to the fixed speed so that the modem will not adjust the serial port speed to the negotiated line speed. To save the new modem settings, type at the prompt. Press Enter. at&w0 The modem sends an OK message.
  • Page 156: Connecting A J-Ex Series Switch To A Network For Out-Of-Band Management

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Connect one end of the phone cable to the modem and the other end to your telephone network. Turn on the power to your modem. Power on the switch. Related Connecting a J-EX Series Switch to a Management Console on page 135...
  • Page 157 Chapter 10: Connecting the Switch Figure 72: Connecting a J-EX Series Switch to a Network for Out-of-Band Management Related Connecting a J-EX Series Switch to a Management Console on page 135 Documentation Management Port Connector Pinout Information for a J-EX8200 Switch on page 44 Cables Connecting the J-EX8200 Switch to Management Devices on page 71...
  • Page 158 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide...
  • Page 159: Performing Initial Configuration

    When you commit changes to the configuration, a new configuration file is created that becomes the active configuration. You can always revert to the factory default configuration. For instructions for reverting to the factory configuration, see the Dell PowerConnect J-Series Ethernet Switch Complete Software Guide for Junos OS at http://www.support.dell.com/manuals...
  • Page 160: Connecting And Configuring A J-Ex Series Switch (Cli Procedure)

    Connecting and Configuring an Switch (J-Web Procedure) on page 146 For information about J-EX Series switch configuration files and interfaces and instructions for reverting to the factory default configuration, see the Dell PowerConnect J-Series Ethernet Switch Complete Software Guide for Junos OS at http://www.support.dell.com/manuals...
  • Page 161 Chapter 11: Performing Initial Configuration Stop Bits—1 DCD State—Disregard To connect and configure the switch from the console: Connect the console port to a laptop or PC using the RJ-45 to DB-9 serial port adapter. The RJ-45 cable and RJ-45 to DB-9 serial port adapter are supplied with the switch. The console port is located on the Switch Fabric and Routing Engine (SRE) module in slot SRE0.
  • Page 162: Connecting And Configuring A J-Ex Series Switch (J-Web Procedure)

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Connecting and Configuring a J-EX Series Switch (J-Web Procedure) There are two ways to connect and configure a J-EX Series switch: one method is through the console using the CLI and the other is using the J-Web interface. This topic describes the J-Web procedure.
  • Page 163 Chapter 11: Performing Initial Configuration On the J-Web login page, type root as the username, leave the password field blank, and click Login. On the Introduction page, click Next. On the Basic Settings page, modify the hostname, the root password, and date and time settings: Enter the hostname.
  • Page 164 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide...
  • Page 165: Removing The Switch And Switch Components

    PART 4 Removing the Switch and Switch Components Removing the Switch on page 151 Removing Switch Components on page 161...
  • Page 166 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide...
  • Page 167: Removing The Switch

    CHAPTER 12 Removing the Switch Powering Off a J-EX8200 Switch on page 151 Removing a J-EX8208 Switch from a Rack or Cabinet on page 152 Removing a J-EX8208 Switch from a Rack or Cabinet Using a Mechanical Lift on page 154 Removing a J-EX8208 Switch from a Rack or Cabinet Without Using a Mechanical Lift on page 156 Powering Off a J-EX8200 Switch...
  • Page 168: Removing A J-Ex8208 Switch From A Rack Or Cabinet

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Shut down the master SRE module from the external management device by issuing operational mode CLI command. This command shuts down request system halt the switch gracefully and preserves system state information. A message displays on the console confirming that the operating system has halted.
  • Page 169 Chapter 12: Removing the Switch NOTE: When you remove multiple switches from a rack or cabinet, remove the switch in the top of the rack or cabinet first and proceed to remove the rest of the switches from top to bottom. CAUTION: At least three people must be available to lift an unloaded switch chassis (all components removed) out of a rack or cabinet.
  • Page 170: Removing A J-Ex8208 Switch From A Rack Or Cabinet Using A Mechanical

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide mechanical lift, see “Removing a J-EX8208 Switch from a Rack or Cabinet Without Using a Mechanical Lift” on page 156. If you installed the switch with cage nuts: Remove the cage nuts from the rack.
  • Page 171 Chapter 12: Removing the Switch Read “General Safety Guidelines and Warnings for J-EX Series Switches” on page 207, with particular attention to “Chassis Lifting Guidelines for J-EX8200 Switches” on page 220. Ensure that the switch has been safely powered off (see “Powering Off a J-EX8200 Switch”...
  • Page 172: Removing A J-Ex8208 Switch From A Rack Or Cabinet Without Using A Mechanical Lift

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Figure 77: Removing a Square-Hole Cage Nut Use the lift to transport the switch to its new location. Figure 78: Removing a J-EX8208 Switch Chassis Using a Mechanical Lift Related Removing a J-EX8208 Switch from a Rack or Cabinet Without Using a Mechanical Lift...
  • Page 173 Chapter 12: Removing the Switch CAUTION: The chassis with only the backplane and no other components weighs approximately 89 lb (41 kg). Lifting the chassis and removing it from a rack or cabinet requires at least three people. The chassis has two handles. Do not lift a fully loaded chassis by the handles; make sure the chassis is empty before you lift it.
  • Page 174 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide If you installed the switch with square-hole cage nuts, a flat-blade (-) screwdriver to remove the cage nuts To remove the switch from the rack (see Figure 79 on page 158): Use the appropriate Phillips (+) screwdriver to remove the 24 mounting screws—and washers if you installed the switch with cage nuts—that attach the chassis...
  • Page 175 Chapter 12: Removing the Switch Figure 80: Removing a Round-Hole Cage Nut (Clip Nut) Figure 81: Removing a Square-Hole Cage Nut After you move the switch to its new location, reinstall the components in the chassis or store the components in antistatic bags. See: Installing an SRE Module in a J-EX8208 Switch on page 118 Installing an SF Module in a J-EX8208 Switch on page 120 Installing a Line Card in a J-EX8200 Switch on page 122...
  • Page 176 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide...
  • Page 177: Removing Switch Components

    CHAPTER 13 Removing Switch Components Removing an AC Power Supply from a J-EX8200 Switch on page 161 Removing a Fan Tray from a J-EX8208 Switch on page 163 Taking the SRE Module Offline in a J-EX8208 Switch on page 165 Removing an SRE Module from a J-EX8208 Switch on page 167 Taking the SF Module Offline in a J-EX8208 Switch on page 168 Removing an SF Module from a J-EX8208 Switch on page 169...
  • Page 178 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide CAUTION: Do not leave the power supply slot empty for a long time while the switch is operational. Either replace the power supply promptly or install a cover panel over the empty slot.
  • Page 179: Removing A Fan Tray From A J-Ex8208 Switch

    Chapter 13: Removing Switch Components Figure 82: Removing an AC Power Supply from a J-EX8200 Switch Related Installing an AC Power Supply in a J-EX8200 Switch on page 114 Documentation AC Power Supply in a J-EX8200 Switch on page 34 Removing a Fan Tray from a J-EX8208 Switch A J-EX8208 switch has a single, field-replaceable fan tray.
  • Page 180 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide CAUTION: The fan tray can be removed and replaced while the switch is operating. However, the fan tray must be replaced within 2 minutes of removing the fan tray to prevent overheating of the chassis.
  • Page 181: Taking The Sre Module Offline In A J-Ex8208 Switch

    Chapter 13: Removing Switch Components Figure 83: Removing a Fan Tray from a J-EX8208 Switch Related Installing a Fan Tray in a J-EX8208 Switch on page 116 Documentation Cooling System and Airflow in a J-EX8208 Switch on page 38 Field-Replaceable Units in a J-EX8208 Switch on page 21 Taking the SRE Module Offline in a J-EX8208 Switch Before removing a Switch Fabric and Routing Engine (SRE) module from a J-EX8208 switch, take the module offline.
  • Page 182: Taking An Sre Module Offline In A Switch With One Sre Module

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Determine whether the SRE module is the master or backup using one of these methods: Look at the (master) LED on the SRE module faceplate. If the LED is lit steady green, the SRE module is the master. If it is blinking green, the SRE module is the backup.
  • Page 183: Removing An Sre Module From A J-Ex8208 Switch

    Chapter 13: Removing Switch Components Removing an SRE Module from a J-EX8208 Switch You must remove the Switch Fabric and Routing Engine (SRE) module from the J-EX8208 switch chassis if you need to replace the module or if you need to remove switch components before moving the chassis without using a mechanical lift.
  • Page 184: Taking The Sf Module Offline In A J-Ex8208 Switch

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Figure 84: Removing an SRE Module from a J-EX8208 Switch Related Installing an SRE Module in a J-EX8208 Switch on page 118 Documentation Switch Fabric and Routing Engine (SRE) Module in a J-EX8208 Switch on page 22 Taking the SF Module Offline in a J-EX8208 Switch The SF module provides switching functionality for a J-EX8208 switch.
  • Page 185: Removing An Sf Module From A J-Ex8208 Switch

    Chapter 13: Removing Switch Components Removing an SF Module from a J-EX8208 Switch on page 169 Switch Fabric (SF) Module in a J-EX8208 Switch on page 25 Removing an SF Module from a J-EX8208 Switch You must remove the Switch Fabric (SF) module from the J-EX8208 switch if you need to replace the module or if you need to remove the switch components before moving the chassis without using a mechanical lift.
  • Page 186: Removing A Line Card From A J-Ex8200 Switch

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Place the SF module in the antistatic bag or on the antistatic mat. If you are not replacing the SF module, install the cover panel over the empty slot by tightening the screws on each side of the cover panel with the screwdriver.
  • Page 187 Chapter 13: Removing Switch Components Electrostatic discharge (ESD) grounding strap Phillips (+) screwdriver, number 2 An antistatic bag or an antistatic mat Replacement line card or a cover panel and its captive screws to cover the empty slot To remove a line card from a J-EX8200 switch (see Figure 87 on page 172): Place the antistatic bag or antistatic mat on a flat, stable surface.
  • Page 188: Disconnecting A Fiber-Optic Cable From A J-Ex Series Switch

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide CAUTION: The line cards in J-EX8200 switches weigh more than 10 lb (4.5 kg). Be prepared to accept the full weight as you slide the line card out of the chassis. Place one hand around the faceplate of the line card and the other hand under the line card to support it.
  • Page 189: Removing A Transceiver From A J-Ex Series Switch

    Chapter 13: Removing Switch Components A rubber safety cap to cover the transceiver A rubber safety cap to cover the fiber-optic cable connector To disconnect a fiber-optic cable from an optical transceiver installed in the switch: Disable the port in which the transceiver is installed by issuing the command: [edit interfaces] user@switch# set interface-name disable WARNING: Do not look directly into a fiber-optic transceiver or into the...
  • Page 190 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Rubber safety caps to cover the transceiver and fiber-optic cable connector A dust cover to cover the port Figure 88 on page 175 shows how to remove an SFP transceiver. The procedure is the same for all transceiver types.
  • Page 191: Switch

    Chapter 13: Removing Switch Components Place the transceiver in the antistatic bag or on the antistatic mat placed on a flat, stable surface. Place the dust cover over the empty port. Figure 88: Removing a Transceiver from a J-EX Series Switch Related Installing a Transceiver in a J-EX Series Switch on page 125 Documentation...
  • Page 192 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide To remove the power cord tray: Use the appropriate Phillips (+) screwdriver to remove the four mounting screws—and washers if you installed the power cord tray with cage nuts—that hold the power cord tray in the rack.
  • Page 193: Switch And Component Maintenance

    PART 5 Switch and Component Maintenance Routine Maintenance on page 179...
  • Page 194 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide...
  • Page 195: Routine Maintenance

    CHAPTER 14 Routine Maintenance Handling and Storing Line Cards in J-EX8200 Switches on page 179 Maintaining Line Card Cables in J-EX8200 Switches on page 182 Maintaining Fiber-Optic Cables in J-EX Series Switches on page 183 Handling and Storing Line Cards in J-EX8200 Switches Components in the line cards are fragile.
  • Page 196: Holding A Line Card

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Holding a Line Card You must hold a line card horizontally when installing it in the chassis. You may hold a line card vertically or horizontally when carrying it. CAUTION: The line cards in J-EX8200 switches weigh more than 10 lb (4.5 kg).
  • Page 197 Chapter 14: Routine Maintenance Figure 92: Do Not Grasp the Connector Edge Never carry the line card while holding the faceplate with only one hand. Do not rest any edge of a line card directly against a hard surface (see Figure 93 on page 181).
  • Page 198: Storing A Line Card

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Do not stack line cards on top of one another or on top of any other component. Place each line card separately in an antistatic bag or on an antistatic mat placed on a flat, stable surface.
  • Page 199: Maintaining Fiber-Optic Cables In J-Ex Series Switches

    Chapter 14: Routine Maintenance Place excess cable out of the way. Do not allow fastened loops of cable to dangle from the connector. Placing fasteners on the loops helps retain their shape. Keep the cable connections clean and free of dust and other particles, which can cause drops in the received power level.
  • Page 200 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Related Handling and Storing Line Cards in J-EX8200 Switches on page 179 Documentation Maintaining Line Card Cables in J-EX8200 Switches on page 182 Connecting a Fiber-Optic Cable to a J-EX Series Switch on page 126...
  • Page 201: Returning Hardware

    PART 6 Returning Hardware Getting Help on page 187...
  • Page 202 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide...
  • Page 203: Getting Help

    ) for help with installation and troubleshooting procedures. See “Online Services” on page 188 for a more extensive list of Dell Support If the preceding steps have not resolved the problem, see “Contacting Dell” on page 191. NOTE: Call Dell Support from a telephone near or at the computer so that the support staff can assist you with any necessary procedures.
  • Page 204: Online Services

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide When prompted by Dell's automated telephone system, enter your Express Service Code to route the call directly to the proper support personnel. For instructions on using the Dell Support, see “Support Service” on page 189.
  • Page 205: Automated Order-Status Service

    Chapter 15: Getting Help Automated Order-Status Service To check on the status of any Dell products that you have ordered, you can go to http://www.support.dell.com , or you can call the automated order-status service. A recording prompts you for the information needed to locate and report on your order. For the telephone number to call for your region, see “Contacting Dell”...
  • Page 206: Before You Call

    Remember to fill out the Diagnostics Checklist (see “Diagnostics Checklist” on page 190). If possible, turn on your computer before you call Dell for assistance and call from a telephone at or near the computer. You may be asked to type some commands at the keyboard, relay detailed information during operations, or try other troubleshooting steps possible only at the computer itself.
  • Page 207: Contacting Dell

    Choose the method of contacting Dell that is convenient for you. Locating a J-EX Series Switch Component Serial Number and Agency Labels Before contacting Dell to request an RMA, you must find the serial number and agency label on the switch or component.
  • Page 208: Locating The Serial Number On A J-Ex8200 Switch Or Component

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Locating the Serial Number on a J-EX8200 Switch or Component To list the switch and switch components and their serial numbers, enter the following command-line interface (CLI) command: user@host> show chassis hardware You see output similar to the following: user@switch>...
  • Page 209: Locating The Serial Number Id Labels On Frus In A J-Ex8200 Switch

    Chapter 15: Getting Help Figure 94: Location of the Serial Number ID Label on J-EX8208 Switch Chassis Locating the Serial Number ID Labels on FRUs in a J-EX8200 Switch The power supplies, fan tray, SRE modules, RE modules, SF module, and line cards installed in a J-EX8200 switch are field-replaceable units (FRUs).
  • Page 210 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide 2000 W AC Power supply—The serial number ID label is on the left side of the power supply (see Figure 95 on page 194). See “Removing an AC Power Supply from a J-EX8200 Switch”...
  • Page 211 Chapter 15: Getting Help Fan tray in a J-EX8208 switch—The serial number ID label is on the rear of the fan tray (see Figure 97 on page 195). See “Removing a Fan Tray from a J-EX8208 Switch” on page 163. Figure 97: Location of the Serial Number ID label on the Fan Tray Used in a J-EX8208 Switch Switch Fabric and Routing Engine (SRE) module in a J-EX8208 Switch—...
  • Page 212 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Switch Fabric (SF) module in a J-EX8208 switch— See Figure 99 on page 196 to see the location of the serial number ID label on the SF module. See “Removing an SF Module from a J-EX8208 Switch”...
  • Page 213: Packing A J-Ex8208 Switch Or Component For Shipping

    Before you begin packing the switch or component, ensure that you: Have retrieved the original shipping carton and packing materials. If you do not have these materials, contact Dell to learn about approved packing materials. See “Returning Items for Warranty Repair or Credit” on page 189.
  • Page 214: Packing A J-Ex8208 Switch For Shipping

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide This topic describes: Packing a J-EX8208 Switch for Shipping on page 198 Packing J-EX8208 Switch Components for Shipping on page 201 Packing a Line Card Used in a J-EX8200 Switch on page 202...
  • Page 215 Chapter 15: Getting Help To pack the switch (see Figure 104 on page 201): Move the wooden pallet and packing material to a staging area as close to the switch as possible. Make sure there is enough space to move the chassis from the rack or cabinet to the wooden pallet.
  • Page 216 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Figure 103: Insert Pallet Fasteners in the Cardboard Box Write the RMA number on the exterior of the box to ensure proper tracking. See “Returning Items for Warranty Repair or Credit” on page 189.
  • Page 217: Packing J-Ex8208 Switch Components For Shipping

    Chapter 15: Getting Help Figure 104: Packing a J-EX8200 Switch Packing J-EX8208 Switch Components for Shipping To pack J-EX8200 switch components, follow the instructions here. For instructions to pack line cards, see “Packing a Line Card Used in a J-EX8200 Switch” on page 202. Before you begin packing a switch component, ensure that you have the following parts and tools available: Antistatic bag, one for each component...
  • Page 218: Packing A Line Card Used In A J-Ex8200 Switch

    Line Cards in J-EX8200 Switches” on page 179). Ensure that you have retrieved the original shipping carton and packing materials. If you do not have these materials, contact Dell to learn about approved packing materials. See “Returning Items for Warranty Repair or Credit” on page 189.
  • Page 219: Dell Support

    Returning Items for Warranty Repair or Credit on page 189 Documentation Removing a Line Card from a J-EX8200 Switch on page 170 Dell Support If you need assistance while troubleshooting a switch, please go to the Dell Support website at http://www.support.dell.com...
  • Page 220 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide...
  • Page 221: Safety Information

    PART 7 Safety Information General Safety Information on page 207 Radiation and Laser Warnings on page 213 Installation and Maintenance Safety Information on page 219 Power and Electrical Safety Information on page 235...
  • Page 222 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide...
  • Page 223: General Safety Information

    CHAPTER 16 General Safety Information General Safety Guidelines and Warnings for J-EX Series Switches on page 207 Definitions of Safety Warning Levels for J-EX Series Switches on page 208 Fire Safety Requirements for J-EX Series Switches on page 210 Qualified Personnel Warning for J-EX Series Switches on page 211 Warning Statement for Norway and Sweden for J-EX Series Switches on page 212 General Safety Guidelines and Warnings for J-EX Series Switches The following guidelines help ensure your safety and protect the J-EX Series switch from...
  • Page 224: Definitions Of Safety Warning Levels For J-Ex Series Switches

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Replace fuses only with fuses of the same type and rating. Do not open or remove chassis covers or sheet-metal parts unless instructions are provided in the hardware documentation for this product. Such an action could cause severe electrical shock.
  • Page 225 Chapter 16: General Safety Information involved with electrical circuitry and be familiar with standard practices for preventing accidents. WARNING: Waarschuwing Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van standaard maatregelen om ongelukken te voorkomen.
  • Page 226: Fire Safety Requirements For J-Ex Series Switches

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide WARNING: Aviso Este símbolo de aviso indica perigo. Encontra-se numa situação que lhe poderá causar danos físicos. Antes de começar a trabalhar com qualquer equipamento, familiarize-se com os perigos relacionados com circuitos eléctricos, e com quaisquer práticas comuns que possam prevenir possíveis acidentes.
  • Page 227: Qualified Personnel Warning For J-Ex Series Switches

    Chapter 16: General Safety Information In the event of an electrical hazard or an electrical fire, you should first turn power off to the equipment at the source. Then use a Type C fire extinguisher, which uses noncorrosive fire retardants, to extinguish the fire. Fire Suppression Equipment Type C fire extinguishers, which use noncorrosive fire retardants such as carbon dioxide and Halotron™, are most effective for suppressing electrical fires.
  • Page 228: Warning Statement For Norway And Sweden For J-Ex Series Switches

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Attention Tout installation ou remplacement de l'appareil doit être réalisé par du personnel qualifié et compétent. Warnung Gerät nur von geschultem, qualifiziertem Personal installieren oder auswechseln lassen. Avvertenza Solo personale addestrato e qualificato deve essere autorizzato ad installare o sostituire questo apparecchio.
  • Page 229: Radiation And Laser Warnings

    CHAPTER 17 Radiation and Laser Warnings Laser and LED Safety Guidelines and Warnings for J-EX Series Switches on page 213 Radiation from Open Port Apertures Warning for J-EX Series Switches on page 216 Laser and LED Safety Guidelines and Warnings for J-EX Series Switches J-EX Series switches are equipped with laser transmitters, which are considered a Class 1 Laser Product by the U.S.
  • Page 230: Class 1 Led Product Warning

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Waarschuwing Klasse-1 laser produkt. Varoitus Luokan 1 lasertuote. Attention Produit laser de classe I. Warnung Laserprodukt der Klasse 1. WARNING: Avvertenza Prodotto laser di Classe 1. Advarsel Laserprodukt av klasse 1. Aviso Produto laser de classe 1.
  • Page 231 Chapter 17: Radiation and Laser Warnings WARNING: Waarschuwing Niet in de straal staren of hem rechtstreeks bekijken met optische instrumenten. WARNING: Varoitus Älä katso säteeseen äläkä tarkastele sitä suoraan optisen laitteen avulla. WARNING: Attention Ne pas fixer le faisceau des yeux, ni l'observer directement à...
  • Page 232: Radiation From Open Port Apertures Warning For J-Ex Series Switches

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Radiation from Open Port Apertures Warning for J-EX Series Switches WARNING: Because invisible radiation might be emitted from the aperture of the port when no fiber cable is connected, avoid exposure to radiation and do not stare into open apertures.
  • Page 233 Chapter 17: Radiation and Laser Warnings WARNING: ¡Atención! Debido a que la apertura del puerto puede emitir radiación invisible cuando no existe un cable de fibra conectado, evite mirar directamente a las aperturas para no exponerse a la radiación. WARNING: Varning! Osynlig strålning kan avges från en portöppning utan ansluten fiberkabel och du bör därför undvika att bli utsatt för strålning genom att inte stirra in i oskyddade öppningar.
  • Page 234 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide...
  • Page 235: Installation And Maintenance Safety Information

    CHAPTER 18 Installation and Maintenance Safety Information Installation Instructions Warning for J-EX Series Switches on page 219 Chassis Lifting Guidelines for J-EX8200 Switches on page 220 Ramp Warning for J-EX Series Switches on page 221 Rack-Mounting and Cabinet-Mounting Warnings for J-EX Series Switches on page 221 Grounded Equipment Warning for J-EX Series Switches on page 225 Maintenance and Operational Safety Guidelines and Warnings for J-EX Series Switches on page 226...
  • Page 236: Chassis Lifting Guidelines For J-Ex8200 Switches

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Varning! Läs installationsanvisningarna innan du kopplar systemet till dess strömförsörjningsenhet. Related General Safety Guidelines and Warnings for J-EX Series Switches on page 207 Documentation Laser and LED Safety Guidelines and Warnings for J-EX Series Switches on page 213...
  • Page 237: Ramp Warning For J-Ex Series Switches

    Chapter 18: Installation and Maintenance Safety Information Mounting a J-EX8208 Switch on a Rack or Cabinet on page 101 Ramp Warning for J-EX Series Switches WARNING: When installing the switch, do not use a ramp inclined at more than 10 degrees. Waarschuwing Gebruik een oprijplaat niet onder een hoek van meer dan 10 graden.
  • Page 238 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide When mounting the switch on a partially filled rack, load the rack from the bottom to the top with the heaviest component at the bottom of the rack. If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the switch in the rack.
  • Page 239 Quando questa unità viene montata in un supporto parzialmente pieno, caricare il supporto dal basso all'alto, con il componente più pesante sistemato sul fondo del supporto. Se il supporto è dotato di dispositivi stabilizzanti, installare tali dispositivi prima di montare o di procedere alla manutenzione dell'unità nel supporto.
  • Page 240 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide WARNING: Advarsel Unngå fysiske skader under montering eller reparasjonsarbeid på denne enheten når den befinner seg i et kabinett. Vær nøye med at systemet er stabilt. Følgende retningslinjer er gitt for å verne om sikkerheten: Switch må...
  • Page 241: Grounded Equipment Warning For J-Ex Series Switches

    Chapter 18: Installation and Maintenance Safety Information Cuando este equipo se vaya a instalar en un bastidor parcialmente ocupado, comenzar la instalación desde la parte inferior hacia la superior colocando el equipo más pesado en la parte inferior. Si el bastidor dispone de dispositivos estabilizadores, instalar éstos antes de montar o proceder al mantenimiento del equipo instalado en el bastidor.
  • Page 242: Maintenance And Operational Safety Guidelines And Warnings For J-Ex Series Switches

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Avvertenza Questa apparecchiatura deve essere collegata a massa. Accertarsi che il dispositivo host sia collegato alla massa di terra durante il normale utilizzo. Advarsel Dette utstyret skal jordes. Forviss deg om vertsterminalen er jordet ved normalt bruk.
  • Page 243 Chapter 18: Installation and Maintenance Safety Information WARNING: Varoitus Räjähdyksen vaara, jos akku on vaihdettu väärään akkuun. Käytä vaihtamiseen ainoastaan saman- tai vastaavantyyppistä akkua, joka on valmistajan suosittelema. Hävitä käytetyt akut valmistajan ohjeiden mukaan. WARNING: Attention Danger d'explosion si la pile n'est pas remplacée correctement.
  • Page 244: Jewelry Removal Warning

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Jewelry Removal Warning WARNING: Before working on equipment that is connected to power lines, remove jewelry, including rings, necklaces, and watches. Metal objects heat up when connected to power and ground and can cause serious burns or can be welded to the terminals.
  • Page 245: Lightning Activity Warning

    Chapter 18: Installation and Maintenance Safety Information WARNING: Advarsel Fjern alle smykker (inkludert ringer, halskjeder og klokker) før du skal arbeide på utstyr som er koblet til kraftledninger. Metallgjenstander som er koblet til kraftledninger og jord blir svært varme og kan forårsake alvorlige brannskader eller smelte fast til polene.
  • Page 246: Operating Temperature Warning

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide WARNING: Warnung Arbeiten Sie nicht am System und schließen Sie keine Kabel an bzw. trennen Sie keine ab, wenn es gewittert. WARNING: Avvertenza Non lavorare sul sistema o collegare oppure scollegare i cavi durante un temporale con fulmini.
  • Page 247 WARNING: Avvertenza Per evitare il surriscaldamento dei switch, non adoperateli in un locale che ecceda la temperatura ambientale massima di 40° C. Per evitare che la circolazione dell'aria sia impedita, lasciate uno spazio di almeno 15.2 cm di fronte alle aperture delle ventole.
  • Page 248: Product Disposal Warning

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Product Disposal Warning WARNING: Disposal of this product must be handled according to all national laws and regulations. WARNING: Waarschuwing Dit produkt dient volgens alle landelijke wetten en voorschriften te worden afgedankt.
  • Page 249 Chapter 18: Installation and Maintenance Safety Information Related General Safety Guidelines and Warnings for J-EX Series Switches on page 207 Documentation General Electrical Safety Guidelines and Warnings for J-EX Series Switches on page 235 AC Power Electrical Safety Guidelines for J-EX Series Switches on page 238 Laser and LED Safety Guidelines and Warnings for J-EX Series Switches on page 213 Installation Instructions Warning for J-EX Series Switches on page 219 Grounded Equipment Warning for J-EX Series Switches on page 225...
  • Page 250 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide...
  • Page 251: Power And Electrical Safety Information

    CHAPTER 19 Power and Electrical Safety Information General Electrical Safety Guidelines and Warnings for J-EX Series Switches on page 235 Prevention of Electrostatic Discharge Damage on J-EX Series Switches on page 236 AC Power Electrical Safety Guidelines for J-EX Series Switches on page 238 AC Power Disconnection Warning for J-EX Series Switches on page 239 Multiple Power Supplies Disconnection Warning for J-EX Series Switches on page 240 TN Power Warning for J-EX Series Switches on page 240...
  • Page 252: Prevention Of Electrostatic Discharge Damage On J-Ex Series Switches

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Evaluated to the TN power system. Canada—Canadian Electrical Code, Part 1, CSA C22.1. Locate the emergency power-off switch for the room in which you are working so that if an electrical accident occurs, you can quickly turn off the power.
  • Page 253 Chapter 19: Power and Electrical Safety Information Always use an ESD grounding strap when you are handling components that are subject to ESD damage, and make sure that it is in direct contact with your skin. If a grounding strap is not available, hold the component in its antistatic bag (see Figure 105 on page 237) in one hand and touch the exposed, bare metal of the switch with the other hand immediately before inserting the component into the switch.
  • Page 254: Ac Power Electrical Safety Guidelines For J-Ex Series Switches

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide AC Power Electrical Safety Guidelines for J-EX Series Switches CAUTION: For switches with AC power supplies, an external surge protective device (SPD) must be used at the AC power source. The following electrical safety guidelines apply to AC-powered switches: Note the following warnings printed on the chassis: “CAUTION: THIS UNIT HAS MORE THAN ONE POWER SUPPLY CORD.
  • Page 255: Ac Power Disconnection Warning For J-Ex Series Switches

    Chapter 19: Power and Electrical Safety Information AC Power Disconnection Warning for J-EX Series Switches WARNING: Before working on the switch or near power supplies, unplug all the power cords from an AC switch. Waarschuwing Voordat u aan een frame of in de nabijheid van voedingen werkt, dient u bij wisselstroom toestellen de stekker van het netsnoer uit het stopcontact te halen.
  • Page 256: Multiple Power Supplies Disconnection Warning For J-Ex Series Switches

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Multiple Power Supplies Disconnection Warning for J-EX Series Switches WARNING: For J-EX Series switches that have more than one power supply connection, you must ensure that all power connections are fully disconnected so that power to the switch is completely removed.
  • Page 257: In Case Of Electrical Accident: Action To Take On A J-Ex Series Switch

    Chapter 19: Power and Electrical Safety Information In Case of Electrical Accident: Action to Take on a J-EX Series Switch If an electrical accident results in an injury, take the following actions in this order: Use caution. Be aware of potentially hazardous conditions that could cause further injury.
  • Page 258 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide...
  • Page 259: Compliance Information

    PART 8 Compliance Information Compliance Information on page 245...
  • Page 260 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide...
  • Page 261: Compliance Information

    CHAPTER 20 Compliance Information Agency Approvals for J-EX Series Switches on page 245 Compliance Statements for EMC Requirements for J-EX Series Switches on page 246 Compliance Statements for Acoustic Noise for J-EX Series Switches on page 248 Declarations of Conformity for J-EX8208 Switches on page 249 Agency Approvals for J-EX Series Switches J-EX Series switches comply with the following standards: Safety...
  • Page 262: Compliance Statements For Emc Requirements For J-Ex Series Switches

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide EN 61000-4-2 ESD EN 61000-4-3 Radiated Immunity EN 61000-4-4 EFT EN 61000-4-5 Surge EN 61000-4-6 Low Frequency Common Immunity EN 61000-4-11 Voltage Dips and Sags Related Compliance Statements for EMC Requirements for J-EX Series Switches on page 246...
  • Page 263: European Community

    Chapter 20: Compliance Information CAUTION: Users should not attempt to make electrical ground connections by themselves, but should contact the appropriate inspection authority or an electrician, as appropriate. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines, and internal metallic water pipe system, if present, are connected together.
  • Page 264: Non-Regulatory Environmental Standards

    Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna.
  • Page 265: Declarations Of Conformity For J-Ex8208 Switches

    Chapter 20: Compliance Information Declarations of Conformity for J-EX8208 Switches...
  • Page 266 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide Related Agency Approvals for J-EX Series Switches on page 245 Documentation Compliance Statements for EMC Requirements for J-EX Series Switches on page 246 Compliance Statements for Acoustic Noise for J-EX Series Switches on page 248...
  • Page 267: Part 9 Index

    PART 9 Index Index on page 253...
  • Page 268 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide...
  • Page 269: Index

    Index airflow Symbols cabinet requirements............67 2-post rack clearance requirements for........67 installation with a mechanical lift......104 cooling system..............38 installation without a mechanical lift....107 environmental requirements........60 mounting the switch............101 fan tray installation............116 power cord tray installation........98 fan tray removal............163 power cord tray removal..........175 ALM (Alarm) LED..............20 removal with a mechanical lift.......154 altitude, acceptable range..........60...
  • Page 270 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide grounding cable and lug, connecting....129 console port jumper cord..............76 connecting to a modem..........139 line card cable maintenance........182 pinouts................43 power cord tray, installing..........98 setting the speed for a modem power cord tray, removing.........175 connection..............137...
  • Page 271 EU Declaration of Conformity.........249 grounding lug European EMC compliance..........247 attaching................129 European Union Declaration of Conformity....249 specifications..............53 factory default configuration..........143 hardware information, Dell support service....189 fan tray..................38 height, chassis................7 installation...............116 humidity (relative), acceptable........60 removal................163 serial number location..........195 initial configuration FCC EMC compliance............247...
  • Page 272 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide LCD panel mechanical lift description.................15 installation with............104 menus..................17 installation without............107 modes.................16 removal with..............154 LEDs removal without............156 AC power supply.............37 menus, LCD.................17 chassis status..............20 modem connection Class 1 product warning..........214 configuring the modem..........138 line cards................30...
  • Page 273 Index ports powering on the switch............133 console port pinouts.............43 problems with your order...........189 management port pinouts.........44 product disposal..............232 USB port specifications..........43 protective earthing terminal, connecting....130 power AC power cord specifications........76 rack installation..............101 AC power supply............34 clearance requirements..........67 AC power supply installation........114 requirements..............63 AC power supply LEDs..........37 safety guidelines and warnings.......221...
  • Page 274 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide RMA (Return Materials Authorization) return serial number location..........196 before you call...............190 taking offline..............168 diagnostics checklist..........190 SFP transceivers..............49 getting help..............187 See also transceivers packing components for shipping......201 SFP+ transceivers..............46 packing line cards for shipping.......202 See also transceivers packing the switch for shipping......198...
  • Page 275 (Norway and Sweden TN power system..............240 only)................212 tolerances, environmental..........60 general................207 tools and equipment for hardware return....197 grounded equipment..........225 training and certification, Dell..........189 jewelry removal............228 transceivers laser and LED..............213 connecting to a fiber-optic cable......126 levels defined...............208 disconnecting from a fiber-optic cable....172 lightening activity............229...
  • Page 276 Dell PowerConnect J-Series J-EX8208 Ethernet Switch Hardware Guide...

This manual is also suitable for:

Powerconnect j-8208

Table of Contents