Dell PowerEdge KVM 1081AD User Manual page 200

Remote console switch
Hide thumbs Also See for PowerEdge KVM 1081AD:
Table of Contents

Advertisement

Object Type
dsProductIDVendor
ProductIDProductVersion Global product version in
dsProductIDDModuleF
WVersion
dsProductIDMainboardF
WVersion
dsProductIDStatus
184
Appendix C: MIBs and SNMP Traps
Description
Product vendor name in
UTF8.
UTF8.
The D module firmware
version string in UTF8.
The main board firmware
version string in UTF8.
Reports the operating state
of the product based on a
mapping of the private
MIB variable
dsServerStatus as follows:
dsServerStatus ready (1)
startupInProgress (2)
subsystemUpgrading (3)
kdbMseSubsystemFailure
(4)
videoSubsystemFailure (5)
OID
1.3.6.1.4.1.10418.3.3.1.1.3
1.3.6.1.4.1.10418.3.3.1.1.4
1.3.6.1.4.1.10418.3.3.1.1.5
1.3.6.1.4.1.10418.3.3.1.1.6
1.3.6.1.4.1.10418.3.3.1.1.7
dsProductIDStatus
ok (3) the product is
operational.
unknown (2) the product is
starting up and is not
operational.
non-critical (4) the product
is upgrading its flash and is
not operational.
non-recoverable (6) a
subsystem failure has
occurred. The product is not
fully operational.
non-recoverable (6) a
subsystem failure has
occurred. The product is not
fully operational.