HP D5970A - NetServer - LCII Configuration Manual page 70

Microsoft cluster for server with hp rack storage/12, hp rack storage/8 & hp netraid-3si adapter
Hide thumbs Also See for D5970A - NetServer - LCII:
Table of Contents

Advertisement

Assign SCSI IDs
To configure the shared disks, change the SCSI ID assignments for each of the HP Storage System/6 units in
the cluster:
1.
Check, and if necessary reassign, SCSI IDs for both the upper and lower cages. Configure the upper and
lower cage DIP switches as indicated below. Note that the upper cage settings are shown in their default
positions.
2.
Reattach and close the HP Storage System/6 side cover. Replace the front bezel. Leave the power off.
3.
Repeat steps 1 and 2 for each HP Storage System/6 to be included in the cluster.
NOTE
The HP Storage System/6 must be operated with the side cover closed to ensure proper
airflow and to prevent radio frequency interference.
WARNING
Do not cable the shared storage units to System A or B at this time. You must configure
the HP NetRAID Adapter and install Microsoft Windows NT Server, Enterprise Edition
before attaching the shared storage unit.
NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide
HP Storage System/6 DIP Switch and Cluster Assignments
to part "4 Cluster Setup and Cabling" of the Installation Guide
Off
On
1
2
3
UPPER
4
CAGE
5
6
1
2
LOWER
3
CAGE
4
5
6